1. Introduktion
Welcome to the user manual for your new ACONEE PC0N 19 SEER Inverter Smart Mini Split AC/Heating System. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your system. Please read it thoroughly before use and retain it for future reference.
2. Sikkerhedsoplysninger
Overhold altid følgende sikkerhedsforanstaltninger for at forhindre personskade eller beskadigelse af enheden.
Generel sikkerhed
- Sørg for, at strømforsyningen stemmer overens med enhedens specifikationer.
- Forsøg ikke selv at reparere eller modificere enheden. Kontakt kvalificeret servicepersonale.
- Hold børn og kæledyr væk fra enheden under drift.
Elektrisk sikkerhed
- Betjen ikke med våde hænder.
- Tag stikket ud af stikkontakten før rengøring eller vedligeholdelse.
- Sørg for korrekt jording.
3. Produktkomponenter
Your ACONEE Mini Split AC/Heating System includes the following main components:
- 1 x Wall mount air handler (Indoor Unit)
- 1 x Outdoor condenser (Outdoor Unit)
- 1 x Pre-flared and insulated copper line set
- 1 x Communication wires
- 1 x Drainage extension with small accessories
- 1 x fjernbetjening

Billede: Overview of the ACONEE Mini Split AC/Heating System, showing the indoor unit, outdoor unit, remote control, and various installation accessories including copper lines, communication wires, and drainage extension.
4. Opsætning og installation
Installation of this mini-split system requires professional knowledge and tools. It is highly recommended to have a certified HVAC technician perform the installation to ensure proper function and safety. Incorrect installation can lead to refrigerant leaks, electrical shock, or fire.
Tjekliste før installation
- Bekræft strømforsyningen voltage (115 volt).
- Sørg for tilstrækkelig plads til både indendørs og udendørs enheder, så der er korrekt luftgennemstrømning og adgang til vedligeholdelse.
- Bekræft, at alle medfølgende komponenter er til stede.
- Acquire necessary tools, including a vacuum pump and gauges for line clearing.
Installationstrin (Overview)
- Placering af indendørsenhed: Select a suitable wall location, ensuring it is strong enough to support the unit's weight and allows for proper air distribution.
- Placering af udendørsenhed: Choose a stable, level surface outdoors, away from direct sunlight or obstructions, with sufficient clearance for airflow.
- Linjesætforbindelse: Connect the pre-flared copper line set between the indoor and outdoor units. Ensure connections are tight to prevent refrigerant leaks.
- Elektriske ledninger: Connect communication wires and power supply according to the wiring diagram provided in the full installation manual. This step requires a qualified electrician.
- Vacuuming the Lines: Tøm kølemiddelledningerne med en vakuumpumpe for at fjerne luft og fugt. Dette er et afgørende trin for systemets effektivitet og levetid.
- Kølemiddelfrigivelse: Once lines are vacuumed, release the pre-charged R-32 refrigerant from the outdoor unit into the system.
- Afløbsforbindelse: Connect the drainage extension to the indoor unit's condensate drain to ensure proper water removal.
- Lækagetjek: Udfør en grundig lækagekontrol af alle forbindelser.

Image: A diagram illustrating the dimensions of the indoor and outdoor units, and the connection of the pre-flared and insulated copper line set, communication wires, and drainage extension. This image provides a visual guide for component placement and connection.
5. Betjeningsvejledning
Your ACONEE Mini Split system offers multiple operating modes and smart control options.
Kontrolmetoder
- Fjernbetjening: Use the included wireless remote for direct control of modes, temperature, fan speed, and other functions.
- Smartphone app: Download the dedicated app to control the unit remotely via Wi-Fi. This allows control from anywhere with an internet connection.
- Stemmestyring: Kompatibel med Alexa og Google Assistant for praktiske stemmekommandoer.

Image: Depicts the smartphone app interface for controlling the ACONEE Mini Split system, alongside an Amazon Echo device, illustrating its compatibility with Alexa for voice control. This highlights the smart control features.
Driftstilstande
The system features 5 primary working modes:
- Automatisk tilstand: Automatically selects cooling or heating based on the set temperature and ambient room temperature.
- Cool tilstand: Provides cooling to lower the room temperature. Can cool down to 60°F.
- Varmetilstand: Provides heating to raise the room temperature. Can heat up to 89°F.
- Tørretilstand (affugtning): Reduces humidity in the room, removing up to 36 pints per day.
- Ventilatortilstand: Circulates air without cooling or heating. Adjustable fan speeds (Low, Medium, High, Auto).

Image: Illustrates the fast cooling and heating capabilities of the ACONEE Mini Split, showing air flow for cooling down to 60°F and heating up to 89°F. Two individuals are shown comfortably in a room, one using a laptop and the other drinking a beverage, demonstrating the system's effectiveness.
Særlige funktioner
- Sove mode: Justerer temperatur og ventilatorhastighed for behagelig søvn, ofte øgetasing temperaturen en smule under afkøling eller sænkningasing during heating over time. Operates quietly at 27 dB.
- ØKO -tilstand: Optimizes operation for energy efficiency, reducing power consumption.
- iFEEL-funktion: The remote control has a temperature sensor that allows the unit to adjust the temperature based on the remote's location, providing more precise comfort.
- Turbofunktion: Giver hurtig afkøling eller opvarmning for hurtigt at nå den ønskede temperatur.

Image: Shows a person sleeping peacefully, with arrows indicating gentle airflow from the indoor unit. Text highlights the quiet operation at 27 dB and the "Sleep Mode" feature, emphasizing a quiet and cozy environment.
6. Vedligeholdelse
Regular maintenance ensures optimal performance and extends the lifespan of your ACONEE Mini Split system.
Filterrensning
The indoor unit features a washable filter. Clean the filter regularly (e.g., every 2-4 weeks, depending on usage) to maintain air quality and efficiency.
- Åbn frontpanelet på indendørsenheden.
- Fjern luftfiltrene.
- Wash filters with lukewarm water and mild detergent.
- Skyl grundigt og lad det lufttørre helt, før det sættes i igen.

Billede: En udskæring view of the indoor unit showing the "Distributed Healthy Filter System." It highlights the top-opened filter and various healthy filters including Silver Ion, Active Carbon, and Catechin filters, as well as a 6-in-1 filter system (Photocatalyst, Active Carbon, Anti-dust static, Catechin, Silver Ion, Vitamin C). This illustrates the multi-stage filtration for improved air quality.
Selvrensende funktion
The unit has a self-cleaning feature that operates at 134.6°F (57°C) to clean the interior coil and prevent mold and bacteria buildup. Refer to your remote control or app instructions to activate this function.
Outdoor Unit Maintenance
- Keep the area around the outdoor unit clear of debris, leaves, and snow to ensure proper airflow.
- The outdoor unit features automatic defrost to prevent ice buildup in cold weather, increasing energy efficiency.
- Periodically inspect the outdoor coil for dirt and clean gently with water if necessary.
7. Fejlfinding
Før du kontakter kundesupport, bedes du læse følgende almindelige problemer og løsninger:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | Ingen strømforsyning; afbryderen er udløst. | Kontroller strømforbindelsen; nulstil afbryderen. |
| Utilstrækkelig køling/opvarmning. | Dirty air filter; blocked outdoor unit; incorrect mode setting; low refrigerant. | Clean air filter; clear obstructions from outdoor unit; select correct mode; contact technician for refrigerant check. |
| Usædvanlig støj. | Loose parts; foreign object in fan; unit not level. | Inspect for loose parts; remove foreign objects; ensure unit is level. If noise persists, contact support. |
| Vandlækage fra indendørsenheden. | Tilstoppet afløbsrør; forkert installation. | Check and clear drain pipe; contact installer for inspection. |
| Fjernbetjening virker ikke. | Afladede batterier; blokering mellem fjernbetjening og enhed. | Udskift batterier; fjern forhindringer. |
8. Specifikationer
| Feature | Detalje |
|---|---|
| Modelnummer | PC0N |
| Kølekapacitet | 9000 BTU (10000 britiske termiske enheder) |
| SEER Rating | 19 SEER |
| Voltage | 115 volt |
| Støjniveau (indendørs) | 34 dB (as low as 27 dB in Sleep Mode) |
| Kølevæsketype | R-32 |
| Produktmål (indendørsenhed) | 34.84" D x 14.4" B x 10.94" H |
| Varens vægt | 23.8 pund |
| Anbefalet dækningsområde | Op til 450 kvadratmeter |
| Særlige funktioner | Inverter Compressor, Remote Controlled, WiFi Enabled, Heating And Cooling Function, Self-Cleaning, Auto Defrost |
9. Garanti og support
ACONEE provides the following warranty and support for your product:
- Garanti: 2 års garanti.
- Opretholdelse: 12 Months Free Maintenance.
- Returnerer: 30 days Unreasonable Return policy.
- Udskiftning af dele: Tilgængelig.
- Technology Support: Your doubts and questions will be responded to within 24 hours.

Image: Displays information about ACONEE's customer support, including email support within 12 hours, 30 days unreasonable return, and 12 months free maintenance and technology support. This reinforces the brand's commitment to customer service.
