ACONEE PC0N

ACONEE PC0N 19 SEER Inverter Smart Mini Split AC/Heating System User Manual

Model: PC0N

1. Introduktion

Welcome to the user manual for your new ACONEE PC0N 19 SEER Inverter Smart Mini Split AC/Heating System. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your system. Please read it thoroughly before use and retain it for future reference.

2. Sikkerhedsoplysninger

Overhold altid følgende sikkerhedsforanstaltninger for at forhindre personskade eller beskadigelse af enheden.

Generel sikkerhed

Elektrisk sikkerhed

3. Produktkomponenter

Your ACONEE Mini Split AC/Heating System includes the following main components:

ACONEE Mini Split AC/Heating System components

Billede: Overview of the ACONEE Mini Split AC/Heating System, showing the indoor unit, outdoor unit, remote control, and various installation accessories including copper lines, communication wires, and drainage extension.

4. Opsætning og installation

Installation of this mini-split system requires professional knowledge and tools. It is highly recommended to have a certified HVAC technician perform the installation to ensure proper function and safety. Incorrect installation can lead to refrigerant leaks, electrical shock, or fire.

Tjekliste før installation

Installationstrin (Overview)

  1. Placering af indendørsenhed: Select a suitable wall location, ensuring it is strong enough to support the unit's weight and allows for proper air distribution.
  2. Placering af udendørsenhed: Choose a stable, level surface outdoors, away from direct sunlight or obstructions, with sufficient clearance for airflow.
  3. Linjesætforbindelse: Connect the pre-flared copper line set between the indoor and outdoor units. Ensure connections are tight to prevent refrigerant leaks.
  4. Elektriske ledninger: Connect communication wires and power supply according to the wiring diagram provided in the full installation manual. This step requires a qualified electrician.
  5. Vacuuming the Lines: Tøm kølemiddelledningerne med en vakuumpumpe for at fjerne luft og fugt. Dette er et afgørende trin for systemets effektivitet og levetid.
  6. Kølemiddelfrigivelse: Once lines are vacuumed, release the pre-charged R-32 refrigerant from the outdoor unit into the system.
  7. Afløbsforbindelse: Connect the drainage extension to the indoor unit's condensate drain to ensure proper water removal.
  8. Lækagetjek: Udfør en grundig lækagekontrol af alle forbindelser.
Diagram showing dimensions and components for ACONEE Mini Split installation

Image: A diagram illustrating the dimensions of the indoor and outdoor units, and the connection of the pre-flared and insulated copper line set, communication wires, and drainage extension. This image provides a visual guide for component placement and connection.

5. Betjeningsvejledning

Your ACONEE Mini Split system offers multiple operating modes and smart control options.

Kontrolmetoder

Smartphone app and voice control for ACONEE Mini Split

Image: Depicts the smartphone app interface for controlling the ACONEE Mini Split system, alongside an Amazon Echo device, illustrating its compatibility with Alexa for voice control. This highlights the smart control features.

Driftstilstande

The system features 5 primary working modes:

Fast Cooling and Heating capabilities of ACONEE Mini Split

Image: Illustrates the fast cooling and heating capabilities of the ACONEE Mini Split, showing air flow for cooling down to 60°F and heating up to 89°F. Two individuals are shown comfortably in a room, one using a laptop and the other drinking a beverage, demonstrating the system's effectiveness.

Særlige funktioner

Sleep Mode and quiet operation of ACONEE Mini Split

Image: Shows a person sleeping peacefully, with arrows indicating gentle airflow from the indoor unit. Text highlights the quiet operation at 27 dB and the "Sleep Mode" feature, emphasizing a quiet and cozy environment.

6. Vedligeholdelse

Regular maintenance ensures optimal performance and extends the lifespan of your ACONEE Mini Split system.

Filterrensning

The indoor unit features a washable filter. Clean the filter regularly (e.g., every 2-4 weeks, depending on usage) to maintain air quality and efficiency.

Distributed Healthy Filter System of ACONEE Mini Split

Billede: En udskæring view of the indoor unit showing the "Distributed Healthy Filter System." It highlights the top-opened filter and various healthy filters including Silver Ion, Active Carbon, and Catechin filters, as well as a 6-in-1 filter system (Photocatalyst, Active Carbon, Anti-dust static, Catechin, Silver Ion, Vitamin C). This illustrates the multi-stage filtration for improved air quality.

Selvrensende funktion

The unit has a self-cleaning feature that operates at 134.6°F (57°C) to clean the interior coil and prevent mold and bacteria buildup. Refer to your remote control or app instructions to activate this function.

Outdoor Unit Maintenance

7. Fejlfinding

Før du kontakter kundesupport, bedes du læse følgende almindelige problemer og løsninger:

ProblemMulig årsagLøsning
Enheden tænder ikke.Ingen strømforsyning; afbryderen er udløst.Kontroller strømforbindelsen; nulstil afbryderen.
Utilstrækkelig køling/opvarmning.Dirty air filter; blocked outdoor unit; incorrect mode setting; low refrigerant.Clean air filter; clear obstructions from outdoor unit; select correct mode; contact technician for refrigerant check.
Usædvanlig støj.Loose parts; foreign object in fan; unit not level.Inspect for loose parts; remove foreign objects; ensure unit is level. If noise persists, contact support.
Vandlækage fra indendørsenheden.Tilstoppet afløbsrør; forkert installation.Check and clear drain pipe; contact installer for inspection.
Fjernbetjening virker ikke.Afladede batterier; blokering mellem fjernbetjening og enhed.Udskift batterier; fjern forhindringer.

8. Specifikationer

FeatureDetalje
ModelnummerPC0N
Kølekapacitet9000 BTU (10000 britiske termiske enheder)
SEER Rating19 SEER
Voltage115 volt
Støjniveau (indendørs)34 dB (as low as 27 dB in Sleep Mode)
KølevæsketypeR-32
Produktmål (indendørsenhed)34.84" D x 14.4" B x 10.94" H
Varens vægt23.8 pund
Anbefalet dækningsområdeOp til 450 kvadratmeter
Særlige funktionerInverter Compressor, Remote Controlled, WiFi Enabled, Heating And Cooling Function, Self-Cleaning, Auto Defrost

9. Garanti og support

ACONEE provides the following warranty and support for your product:

ACONEE customer support information

Image: Displays information about ACONEE's customer support, including email support within 12 hours, 30 days unreasonable return, and 12 months free maintenance and technology support. This reinforces the brand's commitment to customer service.

Relaterede dokumenter - PC0N

Preview ACONEE 13x25 FT Carport Brugermanual og Samlevejledning
Omfattende brugermanual og samlevejledning til ACONEE 13x25 FT kraftig carport. Indeholder reservedelsliste, trinvise instruktioner og kontaktoplysninger til support.