1. Introduktion
This manual provides instructions for the proper use, setup, and maintenance of your Motorola Solutions PMMN4062AL Remote Speaker Microphone. This device is designed for use with compatible two-way radios, offering enhanced communication capabilities in various environments.

Figure 1.1: The Motorola Solutions PMMN4062AL Remote Speaker Microphone alongside its user guide.
2. Produktfunktioner
The PMMN4062AL Remote Speaker Microphone incorporates several features designed for reliable and clear communication:
- IMPRES Audio: Optimizes audio performance, particularly in noisy environments, ensuring clear voice transmission.
- Noise-Canceling Acoustics: Reduces background noise, allowing your voice to be transmitted clearly.
- Nødknappen: A programmable orange button for emergency signaling.
- 3.5 mm lydstik: Allows connection of an earpiece for discreet communication.
- Push-to-Talk (PTT) Switch: For initiating transmissions.
- Swivel Clip: For secure attachment to clothing or gear.
- Quick Disconnect Latch: For easy attachment and removal from compatible radios.
- Robust konstruktion: IP54 rated for dust and water resistance, suitable for demanding conditions.
- Large Housing: Designed for ease of use, even when wearing gloves.

Figur 2.1: En detaljeret view of the microphone's front, highlighting the speaker grille and Motorola logo.
3. Pakkens indhold
Bekræft at alle varer er til stede i din pakke:
- Motorola Solutions PMMN4062AL Remote Speaker Microphone
- User Guide/Instruction Manual

Figure 3.1: Contents as typically found upon opening the product packaging.

Figure 3.2: The product box label, indicating model number PMMN4062AL and manufacturing details.
4. Opsætning
Follow these steps to set up your Remote Speaker Microphone:
- Attach to Radio: Align the quick disconnect latch of the microphone cable with the accessory port on your compatible Motorola Solutions radio. Push firmly until it clicks into place.
- Fastgør mikrofonen: Use the swivel clip on the back of the microphone to attach it to your uniform, vest, or other gear at a convenient location for speaking and listening.
- Connect Earpiece (Optional): If discreet communication is required, insert a compatible 3.5mm earpiece into the audio jack located on the side of the microphone.

Figur 4.1: Eksamples of compatible Motorola APX series radios with which the PMMN4062AL can be used.

Figure 4.2: The side of the microphone, illustrating the swivel clip for attachment and the 3.5mm audio jack.
5. Betjeningsvejledning
To operate your Remote Speaker Microphone:
- Modtagelse af lyd: Audio from the radio will be routed through the speaker on the microphone. Ensure the microphone speaker is not obstructed.
- Transmission (Push-to-Talk): Press and hold the large Push-to-Talk (PTT) button on the side of the microphone. Speak clearly into the microphone grille. Release the PTT button to stop transmitting and return to receive mode.
- Nødknappen: In an emergency, press the orange programmable emergency button. The specific function of this button is configured on your radio. Refer to your radio's user manual for details on emergency signaling.
- Diskret lytning: If an earpiece is connected to the 3.5mm audio jack, audio will be routed to the earpiece instead of the microphone's speaker.
6. Vedligeholdelse
Proper maintenance ensures the longevity and performance of your microphone:
- Rensning: Wipe the microphone's exterior with a damp cloth. Do not use harsh chemicals or abrasive cleaners. Ensure the 3.5mm audio jack and radio connector are free of debris.
- Opbevaring: Store the microphone in a dry, cool place away from direct sunlight and extreme temperatures.
- Inspektion: Periodically inspect the cable for any signs of wear, cuts, or damage. If damage is observed, discontinue use and contact authorized service personnel.
7. Fejlfinding
If you encounter issues with your Remote Speaker Microphone, consider the following:
- Ingen lyd fra højttaler:
- Ensure the microphone is securely connected to the radio.
- Check if an earpiece is connected to the 3.5mm jack; if so, audio will be routed there.
- Verify the radio's volume is set appropriately.
- Uklar eller forvrænget lyd:
- Ensure you are speaking directly into the microphone grille.
- Check for obstructions on the microphone grille.
- Verify the radio's audio settings.
- PTT Button Not Functioning:
- Ensure the microphone is fully connected to the radio.
- Check the radio's settings for external accessory functionality.
8. Specifikationer
| Modelnummer | PMMN4062AL |
| Mærke | Motorola løsninger |
| Mikrofon formfaktor | Lavalier (Remote Speaker Microphone) |
| Dimensioner (L x B x H) | 8 x 3.5 x 2 tommer |
| Varens vægt | 11.7 ounce |
| Ingress Protection (IP) Rating | IP54 (støv- og vandafvisende) |
| Lydstik | 3.5 mm |
| Signal-støjforhold | 78 dB |
| Kompatible enheder | SRX2200, APX7000, APX7000XE, APX 6000, APX 6000XE, APX 4000, APX 3000, APX 1000, APX 900 |
9. Garanti og support