This manual provides detailed instructions for the safe and efficient operation, installation, and maintenance of your Eurom AC3501 Wifi split air conditioner. This portable unit is designed to provide cooling for various mobile environments such as caravans, motorhomes, campers, boats, and mobile homes, as well as for use in residential spaces like living rooms, bedrooms, and offices. Please read this manual thoroughly before initial use and keep it for future reference.
Sikkerhedsinstruktioner
Følg altid følgende sikkerhedsretningslinjer for at forhindre personskade eller beskadigelse af enheden:
- Ensure the power supply matches the unit's requirements (230 Volt).
- Bloker ikke luftindtag eller -udtag.
- Keep the unit away from water and moisture. The unit has an IP24 protection rating, meaning it is protected against solid objects over 12.5mm and splashing water from any direction.
- Forsøg ikke selv at reparere eller modificere enheden. Kontakt kvalificeret servicepersonale.
- Sørg for korrekt ventilation omkring udendørsenheden.
- The unit contains R290 refrigerant. Handle with care and ensure proper disposal.
Produktkomponenter
The Eurom AC3501 is a split air conditioning system consisting of an indoor unit and an outdoor unit, connected by a flexible hose containing refrigerant lines and electrical cables. The system also includes various accessories for installation.

Figure 1: The indoor and outdoor units of the Eurom AC3501 split air conditioner, shown separated. The indoor unit (left) features a circular fan grille and a control panel, while the outdoor unit (right) has a rectangular grille and a handle for portability.

Figure 2: Key installation accessories for the Eurom AC3501. This includes a flexible white air duct, two white mounting brackets with black adjustment knobs, and a white rectangular adapter for connecting the duct to the unit.
Opsætning og installation
The Eurom AC3501 is designed for flexible installation, particularly suitable for temporary setups in caravans or mobile homes. The two units are permanently connected by a flexible hose.
Installationstrin:
- Placering af enhederne:
Identify a suitable location for both the indoor and outdoor units. The indoor unit should be placed inside the space to be cooled, while the outdoor unit must be placed outside, ensuring adequate airflow around it. The connecting hose allows for separation of the units.

Figure 3: The indoor unit (top) and outdoor unit (bottom) of the Eurom AC3501 air conditioner shown stacked, with the flexible connecting hose visible at the rear. This configuration is often used for transport or compact storage.

Figur 4: En side view of the Eurom AC3501 units separated, illustrating the flexible hose that connects them. The hose allows for versatile placement of the indoor and outdoor components.
- Window Installation (Caravan/Motorhome):
For caravan or motorhome use, the unit can be mounted in a window opening using the provided brackets. Secure the indoor unit inside and the outdoor unit outside, ensuring the connecting hose passes through the window opening without kinks.

Figure 5: The Eurom AC3501 air conditioner installed in a caravan window. The indoor unit is visible through the window, and the outdoor unit is mounted below it on the exterior of the caravan, connected by the white hose.
- Strømtilslutning:
Once positioned, connect the power cable to a suitable 230V power outlet. Ensure the outlet is properly grounded and can handle the unit's power consumption (1025 Watts).
Betjeningsvejledning
The Eurom AC3501 can be operated via its integrated control panel or through the Eurom Smart App via Wi-Fi.
Kontrolpanel overview:

Figur 6: Nærbillede view of the Eurom AC3501 control panel. It features a digital display showing temperature (e.g., 18°C) and mode icons, along with touch-sensitive buttons for power, fan speed, mode selection, temperature adjustment (+/-), timer, and Wi-Fi.
- Power knap: Tænder eller slukker for enheden.
- Valg af tilstand: Cycle through cooling, fan-only, and dehumidifier modes.
- Temperaturjustering (+/-): Set the desired temperature. The integrated thermostat will maintain this temperature.
- Blæserhastighed: Adjust the fan speed (low, medium, high).
- Timer funktion: Program the unit to turn on or off at a specific time.
- Wi-Fi/App-kontrol: Connect the unit to your Wi-Fi network and control it remotely using the Eurom Smart App. Refer to the app's instructions for pairing.
For optimal cooling, ensure windows and doors are closed in the area where the unit is operating. The unit has a cooling capacity of 3500 BTU, suitable for spaces up to approximately 24 m³.
Opretholdelse
Regelmæssig vedligeholdelse sikrer dit klimaanlægs levetid og effektivitet.
- Rengøring af forfilteret: The unit is equipped with a pre-filter to capture dust and large particles. This filter should be cleaned regularly (e.g., every two weeks, depending on usage).
- Afbryd enheden fra strømforsyningen før rengøring.
- Locate and remove the pre-filter (refer to the unit's diagram for exact location).
- Rengør filteret med en støvsuger, eller vask det forsigtigt med lunkent vand og et mildt rengøringsmiddel.
- Lad filteret tørre helt, før du sætter det i igen.
- Udvendig rengøring: Tør ydersiden af enheden af med en blød, damp klæde. Brug ikke skrappe kemikalier eller slibende rengøringsmidler.
- Opbevaring: If storing the unit for an extended period, ensure it is clean and dry. Store it in a cool, dry place, ideally in its original packaging.
Fejlfinding
If you encounter issues with your Eurom AC3501, refer to the following common problems and solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | No power supply; power cable not connected; power outage. | Kontroller strømtilslutningen; sørg for, at stikkontakten fungerer; kontroller afbryderen. |
| Utilstrækkelig køling. | Windows/doors open; dirty air filter; unit too small for the room; blocked air inlets/outlets. | Close windows/doors; clean air filter; ensure unit is appropriately sized for the space; clear obstructions. |
| Usædvanlig støj. | Unit not level; foreign object in fan; internal component issue. | Ensure unit is on a flat, stable surface; check for obstructions; if noise persists, contact support. |
| Vandlækage. | Drainage hose blocked or improperly connected; unit not level. | Check drainage hose for kinks or blockages; ensure proper connection; level the unit. |
Hvis problemet fortsætter efter at have forsøgt disse løsninger, bedes du kontakte Euroms kundesupport.
Specifikationer
| Feature | Detalje |
|---|---|
| Model | AC3501 |
| Mærke | Eurom |
| Kølekapacitet | 3500 BTU |
| Cooling Area (max) | 24 m³ |
| Strømforbrug | 1025 watt |
| Voltage | 230 volt |
| Kølemiddel | R290 (Propane, GWP 3) |
| Beskyttelsesklasse | IP24 |
| Dimensioner (produkt) | 37 x 40 x 40 cm |
| Vægt | 23 kilo |
| Særlige funktioner | Dehumidifier, Wi-Fi, App Control |
| Filtertype | Forfilter |
Garanti og support
Eurom products are manufactured to high quality standards. For information regarding warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Eurom website. In case of technical issues or questions not covered in this manual, please contact Eurom customer support.