BDCOM S2900-24T4X-2AC

BDCOM S2900-24T4X-2AC Ethernet Layer-3 Lite Switch User Manual

Model: S2900-24T4X-2AC

1. Introduktion

This manual provides essential information for the installation, operation, and maintenance of the BDCOM S2900-24T4X-2AC Ethernet Layer-3 Lite Switch. Please read this manual thoroughly before using the device to ensure proper setup and functionality. Retain this document for future reference.

2. Produktet er slutview

The BDCOM S2900-24T4X-2AC is a high-performance Ethernet Layer-3 Lite switch designed for various networking environments. It features 24 Gigabit Ethernet (GE) TX ports and 4 10 Gigabit Ethernet (10GE) SFP+ ports, providing flexible connectivity options. The switch also includes a console port for management and supports standard 19-inch rack-mounted installation.

2.1 Nøglefunktioner

  • 1 Console port for device management.
  • 24 Gigabit Ethernet (GE) TX ports for high-speed network connections.
  • 4 10 Gigabit Ethernet (10GE/GE) SFP+ ports for uplink or high-bandwidth connections.
  • AC 110V ~ 220V input, 60 Hz power supply.
  • Ventilatorløst design for lydløs drift.
  • 1U height, suitable for standard 19-inch rack-mounted installation.

2.2 Frontpanelets layout

BDCOM S2900-24T4X-2AC Front Panel Diagram

Figure 1: Front Panel Diagram of BDCOM S2900-24T4X-2AC Switch, highlighting 24 Gigabit RJ45 ports, 4 10G/1G SFP+ ports, and the Console port.

  • Konsolport: RJ45 port for command-line interface (CLI) access.
  • GE TX Ports (1-24): 24 Gigabit Ethernet ports for connecting network devices.
  • 10GE/GE SFP+ Ports (TE1-TE4): 4 SFP+ slots supporting 10 Gigabit or 1 Gigabit fiber optic transceivers.
  • LED-indikatorer: System (SYS), Power (PWR), and individual port status indicators.
BDCOM S2900-24T4X-2AC Front View

Figur 2: Detaljeret front view of the BDCOM S2900-24T4X-2AC switch, showing the arrangement of ports and indicators.

2.3 Bagpanellayout

BDCOM S2900-24T4X-2AC Rear View

Figur 3: Bagside view of the BDCOM S2900-24T4X-2AC switch, displaying the AC power input and power switch.

  • AC strømindgang: Connector for the AC power cord (100-240 VAC, 50/60 Hz).
  • Afbryderen: Tænd/sluk-knap til enheden.

3. Installation

Follow these steps for proper installation of your BDCOM S2900-24T4X-2AC switch.

3.1 Forberedelse af stedet

  • Sørg for, at installationsstedet er rent, tørt og godt ventileret.
  • Maintain an ambient temperature between 0°C and 50°C (32°F and 122°F).
  • Undgå direkte sollys, varmekilder og for meget støv.
  • Ensure adequate space around the switch for proper airflow, especially at the sides where ventilation is located.

3.2 Rackmontering

The switch is designed for standard 19-inch rack-mounted installation (1U height).

  1. Attach the provided rack-mount brackets to the sides of the switch using the included screws.
  2. Juster kontakten med rackstolperne, og fastgør den med passende rackskruer.
  3. Ensure the switch is level and securely fastened in the rack.

3.3 Strømtilslutning

  1. Sørg for, at tænd/sluk-knappen på bagpanelet er i OFF-positionen.
  2. Connect one end of the AC power cord to the power input on the rear panel of the switch.
  3. Connect the other end of the AC power cord to a grounded power outlet (100-240 VAC, 50/60 Hz).
  4. Flip the power switch to the ON position. The Power (PWR) LED on the front panel should illuminate.

3.4 Netværksforbindelser

  • GE TX Ports: Connect standard RJ45 Ethernet cables from your network devices (servers, workstations, other switches) to the GE TX ports (1-24).
  • 10GE/GE SFP+ Ports: Insert compatible SFP+ transceivers into the SFP+ slots (TE1-TE4). Connect fiber optic cables from other network devices or uplinks to these transceivers. Ensure the transceivers and cables match the required speed (1G or 10G).
  • Konsolport: For initial configuration and management, connect a console cable (RJ45 to DB9 or USB) from your management workstation to the console port.

4. Indledende konfiguration

The BDCOM S2900-24T4X-2AC switch can be configured via its Command Line Interface (CLI) through the console port or via a web-baseret grafisk brugergrænseflade (GUI).

4.1 Console Access (CLI)

  1. Connect your computer to the switch's console port using a console cable.
  2. Åbn et terminalemuleringsprogram (f.eks. PuTTY, Tera Term) på din computer.
  3. Konfigurer indstillingerne for den serielle port:
    • Baud rate: 9600
    • Databits: 8
    • Paritet: Ingen
    • Stop Bits: 1
    • Flowkontrol: Ingen
  4. Power on the switch. The boot-up messages will appear in the terminal window.
  5. Log in using the default credentials (refer to the official BDCOM documentation for default username and password).
  6. Begin configuring the switch according to your network requirements. The command structure is similar to Cisco IOS.

4.2 Web-based Management (GUI)

Once the switch has an IP address configured (either manually via CLI or via DHCP), you can access its web interface.

  1. Ensure your management computer is on the same network segment as the switch.
  2. Åbn a web browseren og indtast switchens IP-adresse.
  3. Log ind med de relevante legitimationsoplysninger.
  4. The GUI provides a user-friendly interface for configuring various switch functions. Note that the included PKI certificate may be expired, requiring generation of a new one for secure access.

For detailed command references and advanced configuration, please consult the official BDCOM S2900 series documentation.

5. Betjeningsvejledning

The BDCOM S2900-24T4X-2AC switch operates automatically once configured. Here are general operational guidelines:

  • Tænd/sluk: Use the power switch on the rear panel. Always ensure proper shutdown procedures if available through CLI/GUI before powering off.
  • LED-indikatorer: Overvåg frontpanelets LED'er for driftsstatus:
    • PWR (strøm): Solid green indicates the switch is powered on.
    • SYS (System): Indicates system status (e.g., solid green for normal operation, blinking for activity or errors). Refer to the full manual for specific patterns.
    • Port LED'er: Indicate link status and activity for each GE and SFP+ port.
  • Netværksforbindelse: Ensure all connected devices are properly cabled and configured for network access.
  • Layer-3 Lite Functionality: The switch supports basic Layer-3 routing capabilities. Configure VLANs, IP interfaces, and static routes as needed for inter-VLAN routing and network segmentation.
  • Linkaggregering (LACP): For increased bandwidth and redundancy, configure Link Aggregation Control Protocol (LACP) on multiple ports to form a single logical link (port channel). Ensure a lower value for the 'agg-period' parameter if configuring LACP.

6. Vedligeholdelse

Regelmæssig vedligeholdelse er med til at sikre din switchs levetid og optimale ydeevne.

  • Rensning: Rengør regelmæssigt ydersiden af ​​kontakten med en blød, tør klud. Brug ikke flydende rengøringsmidler eller rengøringsmidler på sprayform. Sørg for, at ventilationsåbningerne er fri for støv og blokeringer.
  • Firmwareopdateringer: Check the BDCOM official website for the latest firmware updates. Applying updates can improve performance, add features, and fix bugs. Follow the provided instructions carefully during firmware upgrades.
  • Sikkerhedskopiering af konfiguration: Regularly back up your switch configuration to an external storage device. This allows for quick restoration in case of a device reset or failure.
  • Miljøovervågning: Sørg for, at driftsmiljøet forbliver inden for de angivne temperatur- og fugtighedsintervaller.

7. Fejlfinding

Dette afsnit indeholder løsninger på almindelige problemer. Kontakt teknisk support ved mere komplekse problemer.

7.1 Strømproblemer

  • Ingen strøm:
    • Kontroller, at netledningen er korrekt tilsluttet både afbryderen og stikkontakten.
    • Sørg for, at tænd/sluk-knappen på bagpanelet er i ON-positionen.
    • Kontroller stikkontakten med en anden enhed for at bekræfte, at den fungerer.

7.2 Problemer med netværksforbindelse

  • Intet link på en port:
    • Check the Ethernet or fiber cable connection. Ensure it is securely plugged into both the switch port and the connected device.
    • Verify the cable is not damaged. Try a different cable.
    • Sørg for, at den tilsluttede enhed er tændt og fungerer korrekt.
    • Check the port status LEDs on the switch. If the LED is off, there might be no link.
    • For SFP+ ports, ensure the transceiver is correctly seated and compatible. The switch can be particular about transceivers.
  • Langsom netværksydelse:
    • Tjek for netværksbelastning.
    • Verify duplex and speed settings on the switch port and connected device.
    • Ensure cables are appropriate for the speed (e.g., Cat5e/6 for Gigabit Ethernet).

7.3 Problemer med administrationsadgang

  • Cannot Access CLI via Console:
    • Bekræft konsolkabelforbindelsen.
    • Check the serial port settings in your terminal emulation program (Baud Rate, Data Bits, Parity, Stop Bits, Flow Control).
    • Sørg for, at den korrekte COM-port er valgt.
  • Cannot Access GUI via Web Browser:
    • Verify the switch has an IP address and your computer can reach it (ping the IP address).
    • Sørg for din web browser is not blocking the connection due to certificate warnings (the default certificate may be expired).
    • Ryd browserens cache, eller prøv en anden browser.

8. Specifikationer

FeatureBeskrivelse
ModelS2900-24T4X-2AC
Havne24 x GE TX ports, 4 x 10GE/GE SFP+ ports, 1 x Console port
Interface TypeSFP, RJ45
StrømindgangAC 100-240V, 50/60 Hz
Fanless DesignJa
Rack enhed1U
InstallationStandard 19-inch rack-mounted
Dimensioner (LxBxH)19.69 x 12.6 x 3.15 tommer (50 x 32 x 8 cm)
Varens vægt8.6 pund (3.9 kg)
Etui materialeMetal
DriftstemperaturOp til 50°C (122°F)

9. Sikkerhedsoplysninger

Overhold følgende sikkerhedsforanstaltninger for at forhindre personskade og beskadigelse af enheden:

  • Always connect the power cord to a grounded electrical outlet.
  • Brug ikke enheden i vådt eller damp forhold.
  • Sørg for korrekt ventilation for at forhindre overophedning.
  • Åbn ikke enheden casing. Overlad al service til kvalificeret personale.
  • Undgå at placere tunge genstande på kontakten.
  • Afbryd strømmen, før du rengør eller flytter enheden.

10. Garanti og support

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official BDCOM webwebsted. Du kan også kontakte din forhandler for at få hjælp.

BDCOM Official Webwebsted: www.bdcom.com.cn

Relaterede dokumenter - S2900-24T4X-2AC

Preview Declaration of Similarity for BDCOM ONU Models GP1704-4GVC-S, P1704-4GVC-S, GP1704-4GV, P1704-4GV
Shanghai Baud Communication Co., Ltd. declares the electrical similarity between ONU models BDCOM GP1704-4GVC-S, P1704-4GVC-S, GP1704-4GV, and P1704-4GV, detailing differences in model names and CATV board presence.
Preview Moxa MGate MB3660-seriens hurtiginstallationsvejledning
Quick installation guide for the Moxa MGate MB3660 series, covering overview, package contents, hardware features, installation, configuration, pin assignments, and specifications for these Modbus TCP to serial gateways.
Preview ALAXALA AX3660S-seriens Layer 3 Gigabit-switche datablad
Datablad for ALAXALA AX3660S-serien, en high-end model af box-type Layer 3-switche designet til missionskritiske netværk, der tilbyder høj pålidelighed og hurtig redundant switching. Funktionerne omfatter netværkspartitionering (VRF), stakfunktionalitet, avancerede routingfunktioner og robust sikkerhed.
Preview PLANET Layer 3 Gigabit/10 Gigabit Administreret Ethernet-switch Brugermanual
Denne brugermanual indeholder omfattende oplysninger om PLANETs Layer 3 Gigabit og 10 Gigabit Managed Ethernet-switche, inklusive modellerne GS-6311, MGS-6311 og XGS-6311-serien. Den dækker funktioner, specifikationer, installation, konfiguration og administration af virksomhedsnetværk.
Preview PLANET XGS-6311/GS-6311/MGS-6311-seriens hurtiginstallationsvejledning
Kom i gang med PLANETs Layer 3 Gigabit/10 Gigabit Managed Ethernet-switche (XGS-6311, GS-6311, MGS-6311-serien) ved hjælp af denne hurtige installationsvejledning. Lær om pakkens indhold, opsætningskrav, konsol og web administration, IP-konfiguration og mere for effektiv netværksimplementering.
Preview Moxa CN2600 Series Quick Installation Guide - Network Terminal Servers
Quick installation guide for Moxa CN2600 Series dual-LAN terminal servers, covering hardware overview, installation, wiring, and software setup. Features 8 or 16 serial ports and dual Ethernet ports.