1. Introduktion
This manual provides comprehensive instructions for the safe and efficient operation of the VOLTCRAFT FG-1302 Function Generator. The FG-1302 is a versatile, mains-powered device designed for generating various waveforms across a wide frequency range. It features two independent channels, a high-resolution display, and supports SCPI commands for remote control.
Nøglefunktioner:
- Frequency output up to 30 MHz
- Frequency resolution of 1 µHz
- Two independent output channels
- 9.14 cm (3.6") TFT LCD display (480 x 272 pixels)
- SCPI command support for remote control
- Holdbar og robust konstruktion
2. Sikkerhedsoplysninger
Read all safety warnings and instructions carefully before operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Strømkilde: Connect the device only to a mains power supply that matches the voltage and frequency specified on the device label.
- Jording: Ensure the power cord is properly grounded. Do not defeat the grounding plug.
- Miljø: Operate the device in a dry, well-ventilated area. Avoid exposure to moisture, extreme temperatures, or direct sunlight.
- Ventilation: Do not block ventilation openings. Adequate airflow is essential to prevent overheating.
- Service: Forsøg ikke selv at servicere enheden. Henvis al service til kvalificeret servicepersonale.
- Rensning: Afbryd strømmen før rengøring. Brug en blød, tør klud. Brug ikke flydende rengøringsmidler eller sprayrengøringsmidler.
3. Pakkens indhold
Verify that all items are present and in good condition upon unpacking. If any items are missing or damaged, contact your supplier immediately.
- VOLTCRAFT FG-1302 Function Generator
- Strømledning
- USB Cable (for SCPI control)
- Brugervejledning (dette dokument)
- BNC to Alligator Clip Cables (quantity may vary)
4. Produktet er slutview
The VOLTCRAFT FG-1302 features a user-friendly interface with a clear display and intuitive controls for efficient operation.
4.1 Frontpanelets layout
The front panel houses the main display, control buttons, rotary knob, and output connectors.

Figur 4.1: Front view of the VOLTCRAFT FG-1302 Function Generator. This image displays the device from a slightly elevated angle, showcasing its main display, control buttons, rotary knob, and the two output channels (Out1 and Out2) with their BNC connectors. The display shows a sine wave with frequency, amplitude, offset, and phase settings. The device is black with a silver stand.

Figur 4.2: Front view of the VOLTCRAFT FG-1302 Function Generator. This image provides a direct front view, highlighting the display which shows a square wave and its associated parameters like frequency, period, amplitude, offset, and phase. The layout of the control buttons and the numerical keypad are clearly visible.

Figur 4.3: Vinklet view of the VOLTCRAFT FG-1302 Function Generator. This perspective shows the device from the front-right, emphasizing its compact design and the ventilation grilles on the side. The front panel display and controls are still prominent, with the display showing a sine wave.

Figur 4.4: En anden vinklet view of the VOLTCRAFT FG-1302 Function Generator. Similar to Figure 4.3, this image provides a slightly different angle, showcasing the device's front panel and the side ventilation. The display shows a square wave, and the overall robust build of the instrument is evident.
4.2 Betjeningselementer og stik
- Vise: 9.14 cm (3.6") TFT LCD for waveform visualization and parameter settings.
- Drejeknap: Used for adjusting parameter values and navigating menus.
- Funktionsknapper: Dedicated buttons for waveform selection (Sine, Square, Pulse, Ramp, Arbitrary, Noise, etc.).
- Numerical Keypad: For direct entry of numerical values (frequency, amplitude, offset).
- Channel Output Buttons (On/Off): Activate or deactivate output for Channel 1 (Out1) and Channel 2 (Out2).
- Output Connectors (Out1, Out2): BNC connectors for signal output.
- Utility Button: Accesses system settings and utility functions.
- Power knap: Tænder eller slukker for enheden.
- USB Port (Rear Panel): For connecting to a computer for SCPI control.
- Mains Power Input (Rear Panel): Til tilslutning af strømkablet.
5. Opsætning
- Placering: Place the function generator on a stable, level surface with adequate ventilation around the unit. Ensure it is away from direct heat sources or excessive moisture.
- Strømtilslutning:
- Sørg for, at afbryderen er i OFF-positionen.
- Connect the provided power cord to the mains power input on the rear panel of the FG-1302.
- Sæt den anden ende af netledningen i en jordet stikkontakt.
- Første gang tændt: Press the Power button on the front panel to turn on the device. The display will illuminate, and the system will perform a self-test.
- Udgangsforbindelse: Connect your test leads (e.g., BNC to alligator clips) to the desired output connector (Out1 or Out2) on the front panel. Connect the other end of the leads to your test circuit or device.
- USB-forbindelse (valgfrit): If you plan to control the device via SCPI commands from a computer, connect the USB cable from the rear USB port of the FG-1302 to an available USB port on your computer. Install any necessary drivers as per the manufacturer's webwebsted eller inkluderet software.
6. Betjeningsvejledning
6.1 Grundlæggende bølgeformgenerering
- Vælg kanal: If operating in dual-channel mode, ensure the desired channel (CH1 or CH2) is selected or active. The display will show the active channel's settings.
- Choose Waveform: Press the corresponding function button (e.g., Sine, Square, Ramp) to select the desired waveform type. The display will update to show the selected waveform and its default parameters.
- Indstil frekvens:
- Use the rotary knob to adjust the frequency value.
- Alternatively, use the numerical keypad to directly enter the frequency value, then press the appropriate unit button (e.g., MHz, kHz, Hz).
- Sæt Amplitude:
- Use the rotary knob to adjust the amplitude (Vpp - Volts peak-to-peak).
- Alternatively, use the numerical keypad to directly enter the amplitude value, then press the appropriate unit button (e.g., Vpp, mVpp).
- Set Offset (DC Offset):
- Use the rotary knob or numerical keypad to set the DC offset voltage.
- Aktivér output: Press the "On/Off" button corresponding to the channel (Out1 or Out2) to enable the signal output. The button will typically illuminate or change color to indicate the output is active.
6.2 Advanced Functions (Refer to full manual for details)
- Vilkårlige bølgeformer: Load and generate custom waveforms.
- Modulering: Apply AM, FM, PM, FSK, ASK, PSK, PWM modulation.
- Sweep Function: Generate signals that sweep across a frequency range.
- Burst-funktion: Generate a specific number of waveform cycles.
- Frekvenstæller: Measure external frequencies.
- Systemindstillinger: Adjust display brightness, language, and other system parameters via the Utility menu.
7. Vedligeholdelse
Proper maintenance ensures the longevity and reliable operation of your FG-1302 Function Generator.
- Rensning: Regularly clean the exterior of the device with a soft, dry, lint-free cloth. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the device. Always disconnect power before cleaning.
- Ventilation: Kontrollér regelmæssigt, at ventilationsåbningerne er fri for støv og snavs. Brug en blød børste eller trykluft til at fjerne eventuelle blokeringer.
- Opbevaring: Når enheden ikke er i brug i længere perioder, skal den opbevares køligt og tørt, væk fra direkte sollys og ekstreme temperaturer.
- Kalibrering: For precise measurements, periodic calibration by a qualified service center is recommended. Refer to the manufacturer's guidelines for recommended calibration intervals.
8. Fejlfinding
This section addresses common issues you might encounter. For problems not listed here, contact technical support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | No power supply; Power cord loose; Power switch off; Blown fuse. | Check power outlet; Ensure power cord is securely connected; Turn power switch ON; Check and replace fuse if necessary (refer to service manual). |
| Ingen signaludgang. | Output channel not enabled; Amplitude set to zero; Incorrect cable connection; Device in standby mode. | Press the "On/Off" button for the desired channel; Adjust amplitude to a non-zero value; Verify BNC cable connections; Ensure device is not in a low-power or standby state. |
| Skærmen er tom eller frosset. | System error; Software glitch. | Turn off the device, wait 10 seconds, then turn it back on. If the problem persists, contact technical support. |
| Incorrect waveform or frequency. | Incorrect settings; External interference. | Verify all waveform parameters (frequency, amplitude, offset, type); Check for external noise sources or improper grounding. |
9. Specifikationer
Technical specifications for the VOLTCRAFT FG-1302 Function Generator.
| Parameter | Værdi |
|---|---|
| Modelnummer | VC-13082820 |
| Mærke | VOLTCRAFT |
| Frekvens output | Op til 30 MHz |
| Frekvens opløsning | 1 µHz |
| Kanaler | 2 |
| Vise | 9.14 cm (3.6") TFT LCD (480 x 272 pixels) |
| SCPI Support | Ja |
| Dimensioner (L x B x H) | 9 x 4 x 13 cm |
| Vægt | 1 kilogram |
| Materiale | Plast |
| Farve | Sort |
10. Garanti og support
The VOLTCRAFT FG-1302 Function Generator comes with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official VOLTCRAFT webhjemmeside for detaljerede garantivilkår.
For technical support, troubleshooting assistance, or service inquiries, please contact VOLTCRAFT customer service through their official website or the contact information provided in your product packaging. When contacting support, please have your model number (FG-1302 / VC-13082820) and purchase details ready.