PRIME e2prime

PRIME 12,000 BTU kanalfri klimaanlæg, varmepumpe Mini Split brugermanual

Model: e2prime | Brand: PRIME

Indledning

Thank you for choosing the PRIME 12,000 BTU Ductless Air Conditioner and Heat Pump Mini Split system. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new unit. Please read this manual thoroughly before installation and use, and keep it for future reference.

This versatile system offers 5 modes for your comfort: Auto, Cool, Dry, Heat, and Fan. It is designed for ease of control with the included backlit LCD remote controller, ensuring optimal climate control in your space. The PRIME mini split system is engineered for energy efficiency, contributing to significant energy savings over time.

Sikkerhedsoplysninger

For at forhindre skader på brugeren eller andre mennesker og materielle skader skal følgende instruktioner følges. Forkert betjening på grund af ignorering af instruktioner kan forårsage skade eller skade.

Produktkomponenter

Your PRIME Mini Split system is shipped in two separate packages and includes the following main components:

PRIME Mini Split Indoor and Outdoor Units

Image: The indoor unit (top) and outdoor unit (bottom) of the PRIME mini split air conditioner system. The indoor unit is a sleek white rectangular shape, and the outdoor unit features a protective grille over its fan and a PRIME logo.

Opsætning og installation

Installation of a ductless mini split system requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC professional to ensure proper operation, safety, and warranty validity.

Udpakning

Carefully unpack both the indoor and outdoor units. Inspect all components for any shipping damage. Report any damage to your supplier immediately. Keep all packaging materials until the unit is fully installed and tested.

PRIME Mini Split Product Packaging

Image: Several PRIME mini split air conditioner units in their original cardboard packaging, stacked in a warehouse setting. The boxes display product information and branding.

Overvejelser om placering

Elektrisk tilslutning

The unit requires a 110/120V power supply. All electrical wiring must comply with local and national electrical codes. A dedicated circuit is recommended.

Tilslutning af kølemiddelledning

The system includes a full installation accessory kit with a quick connector for the refrigerant lines. This simplifies the connection process, but proper vacuuming and leak testing are still crucial and should be performed by a professional.

Betjeningsvejledning

Your PRIME mini split system is controlled via the included backlit LCD remote controller. Familiarize yourself with the remote's buttons and display for optimal use.

Fjernbetjening overview

The remote features a clear LCD display showing current settings, temperature, and mode. Buttons are intuitively placed for easy access to various functions. Refer to the remote control's dedicated section in the full manual for a detailed button layout.

Driftstilstande

Temperaturjustering

Use the temperature up/down buttons on the remote to set your desired room temperature. The display will show the set temperature.

Blæserhastighedskontrol

The unit offers three fan speeds (Low, Medium, High) and an Auto-speed setting. In Auto-speed, the unit adjusts the fan speed automatically based on the operating mode and temperature difference.

Søvn funktion

Activate the Sleep function for energy savings and quiet operation during nighttime hours. The unit will gradually adjust the temperature and fan speed for comfortable sleep.

Automatic Air Swing

The Automatic Air Swing feature ensures even distribution of conditioned air throughout the room by automatically moving the louver. This can be toggled on or off via the remote.

PRIME Mini Split Indoor Unit with R410A Refrigerant Label

Image: The sleek white indoor unit of the PRIME mini split system, featuring a digital display showing "24" and a prominent green circular label indicating "Eco-friendly Refrigerant R410A".

Opretholdelse

Regular maintenance is crucial for the efficient and long-lasting operation of your PRIME mini split system. Always disconnect power to the unit before performing any maintenance.

Filterrensning

The indoor unit is equipped with washable filters. Clean these filters every two weeks or more frequently if the unit is used heavily or in dusty environments. Dirty filters can reduce efficiency and airflow.

  1. Åbn frontpanelet på indendørsenheden.
  2. Fjern luftfiltrene.
  3. Vask filtrene med lunkent vand og et mildt rengøringsmiddel. Skyl grundigt.
  4. Lad filtrene tørre helt i et skyggefuldt område, før de sættes i igen. Udsæt dem ikke for direkte sollys.
  5. Reinstall the dry filters and close the front panel.

Rengøring af udendørsenhed

Periodically check the outdoor unit for debris, leaves, or dirt that may accumulate on the coils or fan blades. Gently clean with a soft brush or vacuum. Do not spray water directly onto electrical components.

Sæsonbestemt vedligeholdelse

Before the start of each cooling or heating season, it is advisable to have a qualified technician perform a comprehensive check of the system, including refrigerant levels, electrical connections, and overall performance.

Fejlfinding

Before contacting customer support, please refer to the following table for common issues and their potential solutions. Many minor problems can be resolved by the user.

ProblemMulig årsagLøsning
Enheden tænder ikke.Ingen strømforsyning; afbryderen er udløst; fjernbetjeningens batterier er døde.Kontroller strømforbindelsen; nulstil afbryderen; udskift batterierne i fjernbetjeningen.
Utilstrækkelig køling/opvarmning.Dirty air filters; blocked outdoor unit; wrong mode selected; low refrigerant.Clean air filters; clear obstructions from outdoor unit; select correct mode; contact professional for refrigerant check.
Usædvanlig støj fra enheden.Loose parts; fan obstruction; unit not level.Check for loose screws; remove any obstructions; ensure unit is level. If noise persists, contact service.
Vandlækage fra indendørsenhed.Clogged drain pipe; improper installation.Check and clear drain pipe; contact professional for inspection.

Tekniske specifikationer

FeatureSpecifikation
MærkenavnPRIME (Generic)
Model Info / Item Model Numbere2prime
Varenummer502259-444237
Kølekapacitet12,000 BTU
Voltage110/120 volt
Sæsonbestemt energieffektivitetsforhold (SEER)12.6 (as per feature bullets) / 12.2 (as per specifications)
Støjniveau32 dB
Varens vægt22 pounds (likely indoor unit only, total weight is higher for two packages)
Capacity (Air Volume)550 Kubikfod
Årligt energiforbrug2800 kilowatttimer pr. år
InstallationstypeOpdelt system
FormfaktorMini-Split
Særlige funktionerHeating And Cooling Function, Sleep Function, Automatic Air Swing, Washable Filters
FarveHvid
Inkluderede komponenterIndoor Unit, Outdoor Unit, Full installation accessory kit with quick connector
Anbefalet gulvarealOp til 600 kvadratmeter
Cable Length (Refrigerant Line)13 fod
Produktmål (indendørsenhed)7" D x 30" B x 10" H
BEE-stjerneklassificering5 Stjerne

Garantioplysninger

The PRIME Mini Split system comes with a limited warranty. Specific warranty terms, including coverage duration for parts and compressor, are typically provided with the product documentation or can be obtained from your point of purchase. Please retain your proof of purchase for warranty claims.

Note: Improper installation or unauthorized servicing may void the product warranty.

Kundesupport

If you encounter issues that cannot be resolved using the troubleshooting guide, or if you require technical assistance or parts, please contact your retailer or the manufacturer's customer support. Have your model number (e2prime) and purchase date ready when contacting support.

For the most up-to-date contact information, please refer to the packaging or the official product webwebsted.

Relaterede dokumenter - e2prime

Preview PRIME LEDWLRHH02 Genopladelig Ultra Slim LED Arbejdslampe Brugermanual
Brugermanual til den genopladelige ultraslanke PRIME LEDWLRHH02 LED-arbejdslampe. Indeholder instruktioner om opstart, betjening, rengøring, vedligeholdelse, fejlfinding og garantioplysninger.
Preview PRIME SmartOutlets brugermanual - Udendørs fjernbetjente smarte stik
Omfattende brugermanual til PRIME SmartOutlets, der beskriver opsætning, installation, sikkerhed, garanti og fejlfinding for udendørs fjernbetjente smarte stik. Lær, hvordan du opretter forbindelse til Wi-Fi, Google Assistant, Alexa og Siri.
Preview PRIME EZ-SET 24-TIMERS DIGITAL TIMER (Model #TNIDEZ1) - Brugsanvisning
Brugsanvisning til PRIME EZ-SET 24-TIMERS DIGITAL TIMER (modelnr. TNIDEZ1), der dækker programmering, funktioner, fejlfinding, sikkerhed, specifikationer og garantioplysninger.
Preview Prime EZ-Set Indendørs Digital Timer Model TNIDP12 Brugermanual
Brugermanual og specifikationer til Prime EZ-Set indendørs digital timer, model TNIDP12. Indeholder programmeringsvejledning, sikkerhedsoplysninger, FCC/IC-regulativer og en begrænset 1-års garanti.
Preview PRIME 2 vægarmatur med stikkontakt og USB-opladere - brugervejledning og garanti
Detaljerede instruktioner, lovgivningsmæssige oplysninger og garantioplysninger for PRIME 2-udtagsvæghanen med USB-opladere (model USB05) fra Prime Wire & Cable, Inc.
Preview Prime TNI2412 24-timers indendørs elektromekanisk timer: Brugermanual og specifikationer
Detaljerede instruktioner, sikkerhedsoplysninger, specifikationer og garantioplysninger for Prime TNI2412 24-timers indendørs elektromekanisk timer. Lær, hvordan du indstiller tænd/sluk-tider, aktuel tid og bypass-funktioner.