1. Produktet er slutview
The Buff 250W Modeling Lamp is designed as a user-replaceable component for the Einstein flash unit. This halogen quartz bulb serves as a continuous light source, aiding in previewing lighting setups before flash discharge. While a modeling bulb is typically included with a new flash unit, having a spare on hand is recommended for uninterrupted operation. Proper handling, including the use of gloves, is crucial to maintain the bulb's lifespan and performance.

Image 1.1: The Buff 250W Modeling Lamp, a clear halogen quartz bulb with a bayonet-style base, designed for the Einstein flash unit.
2. Nøglefunktioner
- Wattage: 250 Watt Halogen Quartz bulb.
- Basistype: Bayonet style base for secure fitting.
- Kompatibilitet: Specifically designed for the Einstein flash unit. Can also be used with retired Zeus standard and Bi-tube heads.
- User-Replaceable: Engineered for easy user replacement.
- Levetid: Bulb lifespan is influenced by proper handling, power levels, and frequency of use.
3. Installation og opsætning
Modelleringen lamp for the Einstein flash unit is designed for user replacement. Follow these instructions carefully to ensure proper installation and to maximize the bulb's lifespan.
- Sikkerhed først: Ensure the flash unit is powered off and unplugged from the electrical outlet before beginning the replacement process. Allow the unit and the old bulb (if present) to cool down completely if it has been in recent use.
- Bær handsker: Always wear clean gloves (e.g., cotton or latex) when handling the new modeling lamp. Oils from your hands can transfer to the bulb's glass surface, creating hot spots that can significantly shorten the bulb's lifespan or cause premature failure.
- Fjern den gamle pære (hvis relevant): Gently grasp the old bulb and twist it counter-clockwise (or pull straight out, depending on the specific Einstein model's socket design) to remove it from its socket. Dispose of the old bulb responsibly.
- Indsæt ny pære: Align the bayonet pins on the base of the new modeling lamp with the corresponding slots in the flash unit's socket. Gently push the bulb into the socket and twist clockwise until it locks securely into place. Do not force the bulb.
- Bekræft installationen: Ensure the bulb is seated firmly and correctly in the socket.
- Tænd: Plug the flash unit back into the electrical outlet and power it on. Test the modeling lamp to confirm it illuminates correctly.
Important: Failure to wear gloves during handling may result in damage to the bulb and void any potential warranty.
4. Betjeningsvejledning
The 250W Modeling Lamp functions as a continuous light source within your Einstein flash unit. Its primary purpose is to provide a visual representation of the light pattern and shadows that will be cast by the flash, allowing you to adjust your lighting setup before taking a photograph.
- Aktivering: Modelleringen lamp is typically controlled via a dedicated switch or setting on the Einstein flash unit. Refer to your Einstein flash unit's manual for specific controls.
- Justering af lysstyrke: Many Einstein units allow for adjustment of the modeling lamp's brightness, often proportional to the flash power setting or independently. Adjust as needed for your preview krav.
- Anvendelse: Brug modelleringen lamp to observe how light falls on your subject, identify hot spots, shadows, and overall light distribution. This helps in precise positioning of your flash unit and light modifiers.
5. Vedligeholdelse og pleje
Korrekt vedligeholdelse sikrer levetiden og optimal ydeevne for din modelbygger.amp.
- Håndtering: Always handle the bulb by its base, not the glass envelope. If the glass is accidentally touched, clean it with a lint-free cloth moistened with rubbing alcohol before installation or use.
- Opbevaring: Store spare bulbs in their original packaging in a cool, dry place to protect them from dust and physical damage.
- Rensning: Do not attempt to clean the inside of the bulb. For the exterior, ensure the bulb is cool and use a dry, soft cloth if necessary.
- Power Cycling: Avoid rapid on/off cycling of the modeling lamp, as this can reduce its lifespan.
6. Fejlfinding
If your modeling lamp ikke fungerer som forventet, skal du overveje følgende almindelige problemer og løsninger:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Modellering lamp lyser ikke. |
|
|
| Pæren brænder hurtigt ud. |
|
|
If issues persist after attempting these solutions, consult the manual for your Einstein flash unit or contact Buff customer support.
7. Produktspecifikationer
| Specifikation | Detalje |
|---|---|
| Mærke | Buff |
| Modelnummer | JD250W |
| Lys type | Halogen |
| Wattage | 250 watt |
| Pære form størrelse | T (rørformet) |
| Lys farve | Varm hvid |
| Antal genstande | 1 |
| Strømkilde | Corded Electric (via flash unit) |
| Fabrikant | Paul C. Buff, Inc. |
| UPC | 850053181450 |
8. Garanti og support
Specific warranty information for the Buff 250W Modeling Lamp is not provided within this manual. For details regarding warranty coverage, terms, and conditions, please refer to the official Paul C. Buff, Inc. webwebstedet eller kontakt deres kundesupport direkte.
For technical support or further assistance with your Buff products, please visit the official Buff webwebstedet eller kontakt deres kundeserviceafdeling. Kontaktoplysninger kan typisk findes på producentens website or within the original packaging of your Einstein flash unit.
Du kan besøge Buff Store on Amazon for more information on Buff products.