1. Introduktion
This manual provides essential information for the safe and effective operation of your Laney Supergroup LA-Studio 3-Watt Tube Guitar Amp Head. The LA-Studio combines classic analog tube tone with modern digital technology, featuring Two Notes Audio Engineering Torpedo technology for versatile sound shaping. It is designed for guitarists seeking a compact, high-quality tube amplifier for studio and practice use.
2. Sikkerhedsinstruktioner
- Læs instruktionerne: Carefully read and understand all safety and operating instructions before using this product.
- Gem instruktionerne: Gem denne vejledning til fremtidig reference.
- Vær opmærksom på advarsler: Overhold alle advarsler på produktet og i betjeningsvejledningen.
- Strømkilde: Connect the unit only to the power supply type described in this manual or marked on the product.
- Jording: Sørg for, at netledningen er korrekt jordforbundet for at forhindre elektrisk stød.
- Ventilation: Bloker ikke ventilationsåbningerne. Sørg for tilstrækkelig luftgennemstrømning omkring enheden for at forhindre overophedning.
- Vand og fugt: Udsæt ikke enheden for regn eller fugt. Placer ikke genstande fyldt med væsker oven på enheden.
- Varme: Hold enheden væk fra varmekilder såsom radiatorer, varmeregistreringsapparater, komfurer eller andre varmeproducerende apparater.
- Service: Forsøg ikke selv at servicere dette produkt. Overlad al service til kvalificeret servicepersonale.
- Rør: Rør amplifiers operate at high voltages and generate significant heat. Do not touch tubes when hot. Tube replacement should be performed by qualified personnel.
- Højttalerforbindelse: Always connect a suitable speaker cabinet or load box to the amplifier's speaker output before powering on, unless using the DI output with an internal load. Failure to do so can damage the amplivligere.
3. Nøglefunktioner
- 3-watt Tube Guitar Amp Hoved
- Integrated Two Notes Audio Engineering Torpedo Technology
- Gain and Presence Knobs for tonal shaping
- Dedicated Headphone Output for silent practice
- Balanced DI Out for direct connection to front of house or audio interface
- Support for Custom DynIRs (Dynamic Impulse Responses)
- Equipped with three ECC83 Large Plate preamp tubes and 12BH7 power tubes
4. Kontrolelementer og forbindelser
Familiarize yourself with the front panel controls and rear panel connections of your LA-Studio amplivligere.

Figur 4.1: Frontpanel view of the Laney Supergroup LA-Studio amplifier head, showing controls and inputs.
Kontrol på frontpanelet:
- Afbryderen: Skifter mellem amplifier's main power ON or OFF.
- BRAKE Switch: Engages or disengages the internal reactive load for silent recording or practice.
- PRESENCE-knap: Adjusts the high-frequency response, adding sparkle and clarity.
- BAS knap: Styrer lavfrekvensudligningen.
- MIDTERSTE knap: Styrer udligningen af mellemfrekvenserne.
- TREBLE knap: Styrer udligningen af højfrekvente lyde.
- GAIN knap: Justerer inputfølsomheden og mængden af overdrive.
- BASS Input Jack: Primary input for guitar, optimized for a fuller low-end response.
- TREBLE Input Jack: Alternative input for guitar, optimized for a brighter, more articulate response.
Tilslutninger på bagpanelet (ikke vist):
- Højttaler output: Connect to a suitable speaker cabinet (e.g., 8 or 16 Ohm).
- Balanced DI Output (XLR): For direct connection to a mixing console or audio interface. This output utilizes the Two Notes Torpedo technology for cabinet simulation.
- Hovedtelefonudgang (6.35 mm jack): Til lydløs øvelse med hovedtelefoner.
- USB-port: For connecting to a computer to access Two Notes Torpedo software for IR loading and parameter tweaking.
- Strømindgang: Tilslut den medfølgende strømledning.
5. Opsætning
- Placering: Place the LA-Studio on a stable, level surface, ensuring adequate ventilation.
- Speaker/Load Connection:
- For traditional use with a speaker cabinet: Connect a speaker cable from the amplifier's Speaker Output to your speaker cabinet. Ensure the cabinet's impedance matches the amplifier's output setting (if applicable, though this model is 3W and likely has a fixed output impedance or internal load).
- For silent recording/practice: The internal reactive load is engaged via the BRAKE switch. You can use the DI Out or Headphone Out without a physical speaker cabinet connected.
- Guitarforbindelse: Connect your guitar to either the BASS or TREBLE input jack on the front panel using a high-quality instrument cable.
- Strømtilslutning: Ensure the POWER switch is in the OFF position. Connect the supplied power cord to the amplifier's power input and then to a grounded AC outlet.
- DI/USB Connections (Optional):
- For recording or live sound: Connect an XLR cable from the Balanced DI Output to your audio interface or mixing console.
- For advanced control and IR loading: Connect a USB cable from the USB port to your computer and install the necessary Two Notes Torpedo software.
6. Betjeningsvejledning
- Tænd: Ensure all connections are secure. Flip the POWER switch to the ON position. The indicator light will illuminate.
- Indledende indstillinger: Start with all tone controls (BASS, MIDDLE, TREBLE, PRESENCE) at their center (5) position and the GAIN knob at a low setting.
- Justering af tone:
- GEVINST: Increase the GAIN knob to achieve more overdrive and sustain. Lower settings provide cleaner tones.
- BAS, MELLEM, DISKANT: Adjust these controls to shape the amplifier's tonal character. Experiment to find your desired sound.
- TILSTEDEVÆRELSE: Use the PRESENCE knob to add brightness and cut through the mix.
- Using the BRAKE Switch: When engaged (ON), the BRAKE switch activates the internal reactive load, allowing you to use the amplifier's tube tone without a speaker cabinet. This is ideal for silent recording via the DI Out or practice with headphones. Ensure a speaker cabinet is disconnected when using the BRAKE function for silent operation.
- Two Notes Torpedo Integration: The LA-Studio features integrated Two Notes Torpedo technology. When using the Balanced DI Output or Headphone Output, this technology provides high-quality cabinet simulations (DynIRs). Connect via USB to your computer to customize and load different DynIRs, adjust microphone placement, and fine-tune other parameters using the Two Notes software.
- Brug af hovedtelefoner: Connect headphones to the Headphone Output for private practice. The volume will be controlled by the amplifier's overall output level (if applicable, or a dedicated headphone volume if present, which is not explicitly listed but implied).
- Sluk: Before disconnecting any cables or moving the amplifier, flip the POWER switch to the OFF position and allow the unit to cool down.
7. Vedligeholdelse
- Rensning: Rengør amplifier with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Ventilation: Regularly check that ventilation openings are clear of dust and debris.
- Udskiftning af rør: Vacuum tubes have a finite lifespan. If you notice a decrease in performance or unusual noise, tubes may need replacement. This procedure involves high voltages and should only be performed by qualified service technicians.
- Opbevaring: Når den ikke er i brug i længere perioder, skal den opbevares ampOpbevar apparatet på et køligt, tørt sted, væk fra direkte sollys og ekstreme temperaturer.
8. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Ingen lyd | Power not on; speaker/load not connected; guitar cable faulty; volume/gain too low. | Ensure POWER switch is ON. Verify speaker/load connection. Check guitar cable. Increase GAIN and other volume controls. |
| Svag eller forvrænget lyd | Faulty tubes; incorrect impedance match; damaged speaker cable; input signal too hot. | Consult a qualified technician for tube inspection/replacement. Ensure correct speaker impedance. Check speaker cable. Adjust guitar output or amplifier GAIN. |
| Brummen eller uønsket støj | Ground loop; faulty cables; proximity to other electronic devices; worn tubes. | Try a different power outlet. Use shielded cables. Move away from other electronics. Consult technician for tube check. |
| DI output not working | XLR cable faulty; mixer/interface input issue; BRAKE switch not engaged (if silent operation desired). | Check XLR cable. Verify mixer/interface settings. Ensure BRAKE switch is ON for silent DI use. |
Hvis problemet fortsætter efter at have forsøgt disse løsninger, bedes du kontakte Laney kundesupport eller en kvalificeret servicetekniker.
9. Specifikationer
| Model | LA-Studio |
| Output Wattage | 3 watt |
| Rør komplement | 3 x ECC83 (Preamp), 2 x 12BH7 (Power) |
| Dimensioner (L x B x H) | 27.7 x 12.9 x 11.8 tommer |
| Varens vægt | 21 pund |
| Farve | Sort |
| Materiale | Metal |
| Kompatible enheder | Guitar |
| Konnektortyper | 6.35mm Jack (Inputs, Headphone), USB, XLR (DI Out) |
| Strømkilde | Elektrisk med ledning |
10. Garanti og support
Laney products are designed for reliability and performance. For information regarding warranty coverage, product registration, or technical support, please visit the official Laney Amplifikation website or contact your authorized Laney dealer.
Online ressourcer: www.laney.co.uk
Always refer to the official Laney webwebsted for de mest opdaterede oplysninger og supportressourcer.