Noark B1H3D15

Noark B1H UL 489 Miniature Circuit Breaker User Manual

Model: B1H3D15

1. Introduktion og overview

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Noark B1H UL 489 Miniature Circuit Breaker, Model B1H3D15. This device is designed to protect electrical circuits from overcurrents, which can result from overloads or short circuits. It is a critical component in electrical distribution systems, ensuring safety and preventing damage to equipment.

The B1H series circuit breakers are UL 489 listed, indicating compliance with rigorous safety standards for molded-case circuit breakers. This specific model is a 3-pole, 15A breaker with a D-curve tripping characteristic, suitable for 480Y/277 Vac systems and featuring a 10 kA interrupting capacity with box lug terminals.

2. Sikkerhedsoplysninger

ADVARSEL: Electrical shock hazard. Installation and servicing of this equipment should only be performed by qualified, licensed electricians. Failure to follow these instructions can result in serious injury or death.

  • Always disconnect power at the main service panel before working on circuit breakers or any electrical wiring. Verify that power is off using a voltage tester.
  • Do not install or operate this device if it appears damaged.
  • Ensure all wiring connections are secure and properly torqued according to specifications to prevent loose connections and overheating.
  • Brug passende personlige værnemidler (PPE), herunder isolerede handsker og sikkerhedsbriller.
  • Adhere to all local and national electrical codes (e.g., NEC in the USA).
  • This circuit breaker is designed for specific voltage og aktuelle ratings. Overskrid ikke disse ratings.

3. Produktfunktioner

The Noark B1H UL 489 Miniature Circuit Breaker offers the following key features:

  • UL 489 Opført: Certified for branch circuit protection, ensuring high safety and performance standards.
  • 3-Pole Configuration: Provides protection for three-phase electrical systems.
  • 15 Ampere vurdering: Suitable for circuits requiring 15A overcurrent protection.
  • D-Curve Tripping Characteristic: Designed for circuits with high inrush currents, such as motors or transformers, providing delayed tripping for short-duration overloads.
  • High Interrupting Capacity: 10 kA at 480Y/277 Vac, capable of safely interrupting high fault currents.
  • Box Lug Terminals: Facilitates secure and reliable wire connections.
  • Plug-In Mount: Designed for easy installation into compatible panelboards or enclosures.
Noark B1H UL 489 3-Pole Miniature Circuit Breaker

Figur 3.1: Forside view of the Noark B1H UL 489 3-Pole Miniature Circuit Breaker, showing the ON/OFF switch and terminal connections.

4. Opsætning og installation

Installation of the Noark B1H Miniature Circuit Breaker must be performed by a qualified electrician in accordance with all applicable electrical codes and standards.

  1. Strømafbrydelse: Before beginning any work, ensure that the main power supply to the panelboard or enclosure is completely disconnected and locked out/tagged out. Verify zero voltage with a suitable testing device.
  2. Montering: The B1H circuit breaker is designed for plug-in mounting. Align the breaker with the appropriate slots on the bus bar within the panelboard and firmly push it into place until it is securely seated.
  3. Ledningsforbindelser:
    • Identify the line (incoming power) and load (outgoing circuit) terminals. The line terminals are typically at the top, and load terminals at the bottom, but always refer to the markings on the breaker.
    • Strip the insulation from the circuit wires to the length specified by the breaker's terminal design (typically indicated on the breaker or in its documentation).
    • Insert the stripped wires into the box lug terminals. For 3-pole breakers, connect the three phase conductors to the respective terminals.
    • Tighten the terminal screws to the torque specifications provided by the manufacturer. Over-tightening can damage the terminals, while under-tightening can lead to loose connections and overheating.
  4. Verifikation: Double-check all connections for tightness and correct polarity. Ensure no bare wires are exposed outside the terminals.
  5. Panellukning: Once installation is complete and verified, close the panelboard cover securely.
  6. Strømgendannelse: Genopret strømmen til hovedservicepanelet.
Side view of a Miniature Circuit Breaker, showing DIN rail clip

Figur 4.1: Side view of a Miniature Circuit Breaker, illustrating the general form factor and potential DIN rail mounting clip.

5. Betjeningsvejledning

The Noark B1H Miniature Circuit Breaker operates with a simple ON/OFF toggle mechanism and automatically trips in response to overcurrent conditions.

  • Tænder: To energize the circuit, push the toggle handle firmly to the "ON" position.
  • Slukker: To de-energize the circuit, push the toggle handle firmly to the "OFF" position.
  • Udløst tilstand: If an overload or short circuit occurs, the breaker will automatically trip. The toggle handle will move to a central or "TRIPPED" position, which is typically between ON and OFF.
  • Nulstilling af en udløst afbryder:
    1. First, identify and resolve the cause of the trip (e.g., unplug overloaded devices, fix short circuits).
    2. Push the toggle handle completely to the "OFF" position. You may feel a slight click as it resets internally.
    3. Then, push the toggle handle firmly to the "ON" position to restore power to the circuit.

Note: If the breaker repeatedly trips, do not continue to reset it without investigating the underlying electrical issue. Persistent tripping indicates a serious problem that requires immediate attention from a qualified electrician.

6. Vedligeholdelse

Noark B1H Miniature Circuit Breakers are designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended to ensure continued safety and performance.

  • Visuel inspektion (årligt): With power disconnected, visually inspect the breaker and its terminals for any signs of damage, discoloration, loose connections, or corrosion.
  • Rensning: If necessary, gently clean the exterior of the breaker with a dry, lint-free cloth. Do not use liquid cleaners or solvents.
  • Terminaltæthed: Periodically check the tightness of the terminal screws, especially after initial installation and during routine electrical system checks. Re-torque to manufacturer specifications if needed.
  • Test: While not typically required for residential or light commercial applications, in some industrial settings, periodic functional testing of circuit breakers may be part of a preventative maintenance program. This should only be performed by certified professionals using specialized equipment.

Vigtig: Do not attempt to open or repair the circuit breaker. If the breaker is damaged or malfunctions, it must be replaced by a new, equivalent unit.

7. Fejlfinding

Most issues with circuit breakers relate to tripping. Understanding why a breaker trips is key to troubleshooting.

ProblemMulig årsagLøsning
Breaker rejser ofte.
  • Overloaded circuit (too many devices).
  • Short circuit in wiring or appliance.
  • Jordfejl.
  • Faulty appliance or equipment.
  • Breaker is undersized for the load.
  • Reducer belastningen på kredsløbet.
  • Inspect wiring and appliances for damage.
  • Consult an electrician to diagnose and repair faults.
  • Replace faulty appliance.
  • Consult an electrician to assess circuit capacity and breaker sizing.
Afbryderen nulstilles ikke.
  • Persistent short circuit or severe overload.
  • Internal damage to the breaker.
  • Sørg for at årsagen til problemet er løst, før du forsøger at nulstille.
  • If the problem persists after resolving the fault, the breaker may be damaged and needs replacement by a qualified electrician.
Afbryderen føles varm at røre ved.
  • Overbelastningstilstand.
  • Løse ledningsforbindelser.
  • Internal fault in the breaker.
  • Immediately reduce the load on the circuit.
  • Have an electrician inspect and tighten connections.
  • Replace the breaker if it is faulty.

Always consult a qualified electrician for any electrical issues you are unable to safely diagnose or resolve.

8. Specifikationer

ParameterVærdi
MærkeNoark
ModelB1H3D15 (Part Number: 1000846)
Afbryder typeMiniature Circuit Breaker (MCB)
StandardUL 489 opført
Antal poler3P
Nominel strøm15A
Nominel voltage480Y/277 Vac
Afbrydelseskapacitet (kA)10 kA
TrippingskurveD Kurve
TerminaltypeKasseluge
MonteringstypePlug-in montering
Dimensioner (ca.)6 x 6 x 6 tommer (pakkemål)

9. Garanti og support

Specific warranty terms and conditions for the Noark B1H UL 489 Miniature Circuit Breaker are provided by the manufacturer, Noark. Please refer to the official Noark website or the documentation included with your purchase for detailed warranty information, including coverage period and claims procedures.

For technical support, product inquiries, or assistance with troubleshooting beyond the scope of this manual, please contact Noark customer service directly. Contact information can typically be found on the manufacturer's official webwebsted eller produktemballage.

Fabrikant: Noark

Webwebsted: www.noark-electric.com (Note: This is a general link and may not be the exact support page. Please verify on product packaging.)

Relaterede dokumenter - B1H3D15

Preview NOARK M6-3P4W støbte afbrydere og tilbehørskatalog
Udforsk NOARK M6-3P4W støbte afbrydere (MCCB'er) og deres tilbehør med dette omfattende katalog. Find detaljerede specifikationer, produktlister, udvælgelsesvejledninger og tekniske oplysninger om industrielle kredsløbsbeskyttelsesløsninger.
Preview NOARK M3-serien elektrisk støbt afbryder - Teknisk oversigtview og specifikationer
Detaljeret teknisk oversigtview og specifikationer for NOARK M3-serien af ​​elektroniske støbte afbrydere (MCCB'er). Dækker modeller som M3SX, M3S400EN3 og M3S400EN4, der tilbyder nominelle værdier op til 600V og 400A. Inkluderer parametre, detaljer om overstrømsrelæer, vejledning til valg og tilgængeligt tilbehør.
Preview NOARK Flangehåndtagsmekanisme Samlingsvejledning
Omfattende vejledning til installation, montering og funktionskontrol af NOARK flangehåndtagsmekanisme, kompatibel med M1/M2/M3/M4/M5 afbrydere.
Preview Noark Ex9FP Sikringsafbryder - Installations- og monteringsvejledning
Omfattende vejledning til installation og montering af Noark Ex9FP sikringsafbryderen, inklusive tekniske specifikationer, ledningsdiagrammer og sikkerhedsforanstaltninger. Designet til DIN-skinnemontering.
Preview NOARK Kontaktorer, Relæer og Manuelle Motorstartere Katalog
Opdag NOARK Electric-kataloget med et omfattende udvalg af lavvolumen-brænderetagElektriske komponenter, herunder kontaktorer, relæer og manuelle motorstartere til industrielle applikationer. Udforsk produkter af høj kvalitet, der er designet til pålidelighed, ydeevne og enestående værdi.
Preview NOARK UL 98 Ikke-smeltelig afbryderkatalog
Katalog med detaljerede oplysninger om NOARKs UL 98 ikke-smeltelige roterende afbrydere, inklusive produkter overview, specifikationer, udvælgelsesvejledning og tilbehør. Dækker funktioner, certificeringer, dimensioner og information om reduktion af rating.