1. Introduktion
This manual provides essential information for the proper installation, operation, and maintenance of the Fire-Lite HPF-PS6 Remote Power Supply. Please read this manual thoroughly before attempting to install or operate the unit. Retain this manual for future reference.
2. Vigtige sikkerhedsoplysninger
ADVARSEL: Risiko for elektrisk stød. Afbryd strømmen før service.
- Installation og service må kun udføres af kvalificeret personale.
- Observe all local and national electrical codes and regulations.
- Sørg for, at strømforsyningen er korrekt jordet.
- Udsæt ikke enheden for fugt eller ekstreme temperaturer.
- Bekræft input voltage matches the unit's specifications (120VAC).
3. Produktet er slutview
The Fire-Lite HPF-PS6 is a 6.0 Amp, 120VAC remote power supply designed to provide reliable power for fire alarm and security systems. Its robust design ensures stable operation in critical applications.
3.1 Nøglefunktioner
- 6.0 Amps output current capacity.
- 120VAC indgang voltage.
- Red enclosure for easy identification in fire safety installations.
- Designed for remote power applications in fire detection signaling service.
3.2 Komponenter
The HPF-PS6 unit consists of a durable red metal enclosure housing the power supply circuitry and terminal blocks for connections.

Figure 1: Fire-Lite HPF-PS6 Remote Power Supply, showing the red enclosure and Honeywell branding.
4. Opsætning og installation
Proper installation is crucial for the safe and reliable operation of the HPF-PS6. Always consult a qualified electrician or fire alarm technician for installation.
4.1 Udpakning
- Tag forsigtigt strømforsyningen ud af emballagen.
- Undersøg enheden for tegn på forsendelsesskader. Rapporter eventuelle skader til din leverandør med det samme.
- Kontroller, at alle komponenter, der er anført på følgesedlen, er til stede.
4.2 Montering
- Select a suitable location that is dry, well-ventilated, and within the specified operating temperature range.
- Mount the unit securely to a wall or other stable surface using appropriate fasteners. Ensure the mounting surface can support the weight of the unit.
- Allow adequate clearance around the unit for ventilation and access to wiring terminals.
4.3 Ledningsføring
All wiring must comply with local and national electrical codes. Refer to the wiring diagram inside the unit's enclosure for specific connection points.
- Indgangseffekt: Connect the 120VAC input power to the designated terminals. Ensure the power source is protected by an appropriate circuit breaker.
- Udgangseffekt: Connect the output terminals to the devices requiring power, observing correct polarity.
- Jording: Sørg for, at enheden er korrekt jordforbundet til en pålidelig jordforbindelse.
- Battery Connections (if applicable): If the unit supports backup batteries, connect them according to the internal wiring diagram, observing polarity.
5. Betjeningsvejledning
Once properly installed and wired, the HPF-PS6 operates automatically to provide regulated power.
5.1 Tænd
- After all wiring is complete and verified, apply 120VAC power to the unit.
- The unit should power up and begin supplying regulated DC power to connected devices.
5.2 Statusindikatorer
The HPF-PS6 may include LED indicators to show its operational status. Refer to the label on the unit or internal documentation for specific indicator meanings (e.g., Power ON, Fault, Battery Low).
6. Vedligeholdelse
The Fire-Lite HPF-PS6 is designed for minimal maintenance. However, periodic checks are recommended to ensure continued reliable operation.
- Årlig inspektion: Annually inspect the unit for any signs of physical damage, loose connections, or excessive dust accumulation.
- Rensning: Rengør om nødvendigt forsigtigt enhedens yderside med en tør, blød klud. Brug ikke flydende rengøringsmidler eller opløsningsmidler.
- Batteritjek (hvis relevant): If backup batteries are used, check their condition and voltage periodically as per battery manufacturer recommendations. Replace batteries as needed.
7. Fejlfinding
This section provides solutions to common issues. For problems not listed here, contact Fire-Lite technical support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Ingen strømudgang | No 120VAC input power; Blown fuse/breaker; Internal fault. | Check input power source and circuit breaker. Verify fuses. If problem persists, contact support. |
| Fault Indicator ON | Overload; Short circuit on output; Battery fault (if applicable). | Check connected devices for short circuits or overloads. Inspect battery connections and condition. |
| Enhed overophedning | Utilstrækkelig ventilation; Overbelastning. | Ensure adequate airflow around the unit. Reduce load if exceeding specifications. |
8. Tekniske specifikationer
| Specifikation | Værdi |
|---|---|
| Modelnavn | HPF-PS6 |
| Fabrikant | FIRE-LITE |
| Varenummer | GHPFPS6 |
| Input bindtage | 120VAC |
| Output Current Rating | 6 Amps |
| Output Wattage | 720 watt |
| Afkølingsmetode | Luft |
| Vare Pakke Antal | 1 |
9. Garanti og support
Fire-Lite products are manufactured to high standards and are backed by a limited warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Fire-Lite webwebsted.
For technical support, service, or replacement parts, please contact your authorized Fire-Lite distributor or customer service representative. Provide the model number (HPF-PS6) and serial number (if applicable) when contacting support.