1. Introduktion
This manual provides essential information for the safe operation, maintenance, and troubleshooting of your A-iPower SUA4300iD Dual Fuel Portable Inverter Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
The A-iPower SUA4300iD is a versatile inverter generator designed for various applications, offering both gasoline and propane fuel options. It features a 149cc OHV 4-cycle engine, providing 4300 starting watts and 3450 running watts on gasoline, and 3900 starting watts and 3100 running watts on propane. Its inverter technology delivers clean power suitable for sensitive electronics.

Image 1.1: The A-iPower SUA4300iD Dual Fuel Portable Inverter Generator, showcasing dens kompakte design og kontrolpanel.
2. Sikkerhedsoplysninger
Prioritér altid sikkerheden, når du bruger generatoren. Manglende overholdelse af sikkerhedsinstruktionerne kan resultere i alvorlig personskade eller død.
- Kuliltefare: Generators produce carbon monoxide (CO), an odorless, colorless gas that can kill you. Operate the generator outdoors in a well-ventilated area, far from windows, doors, and vents. Never operate it inside a home, garage, basement, crawl space, or other enclosed area.
- Brandfare: Brændstof er meget brandfarligt. Påfyld ikke brændstof, mens motoren kører eller er varm. Opbevar brændstof i godkendte beholdere på et godt ventileret sted væk fra antændelseskilder.
- Fare for elektrisk stød: Do not operate the generator in wet conditions. Ensure all electrical connections are secure and dry. Never connect the generator directly to a building's electrical system without a transfer switch installed by a qualified electrician.
- Varme overflader: Generatorens motor og lyddæmper bliver meget varme under drift og forbliver varme i et stykke tid efter nedlukning. Undgå kontakt med varme overflader for at forhindre forbrændinger.
- CO-sensor: This generator is equipped with a CO sensor that will automatically shut down the engine if dangerous levels of carbon monoxide are detected. Do not disable or bypass this safety feature.
3. Komponenter og kontroller
Familiarize yourself with the various components and controls of your generator.
3.1 Kontrolpanel

Billede 3.1: Detaljeret view of the generator's control panel, highlighting various outlets and indicators.
- Data Center Display: Viser voltage, frequency, hours, power output, and indicators for output ready, overload, and low oil.
- CO Sensor Indicator Light: Illuminates when carbon monoxide levels are detected, triggering an automatic shutdown.
- LED lys: Provides illumination for the control panel in low-light conditions.
- Udsalgssteder:
- 1x 8.3A 12V DC outlet
- 1x L5-30R 30A 120V outlet (RV Ready)
- 1x Duplex 5-20R 20A 120V outlets
- Brændstofvælgerkontakt: For choosing between gasoline and propane operation.
- Propane Inlet: Connection point for the LPG hose.
- Parallel Ports: Allows connection of two compatible A-iPower inverter generators for increased power output.
3.2 Medfølgende komponenter

Image 3.2: Visual representation of items included with the generator, such as oil, funnel, and cables.
The generator package includes:
- Owner's Manual/Quick Start Guide
- Motorolie og tragt
- 30A RV Adaptor
- 12V DC Charging Cables
- LPG slange med regulator
- Værktøjssæt
Note: Parallel cables are sold separately.
4. Opsætning
Før første brug er korrekt opsætning afgørende for sikker og effektiv drift.
4.1 Tilsæt motorolie
- Placer generatoren på en plan overflade.
- Fjern oliepåfyldningsdækslet/målepinden.
- Using the provided funnel, carefully add the recommended engine oil (SAE 10W-30 is typically suitable for general use) until it reaches the upper mark on the dipstick. Do not overfill.
- Sæt oliepåfyldningsdækslet/målepinden sikkert på igen.
4.2 Tilsæt brændstof
This generator operates on either gasoline or propane (LPG).
Til benzindrift:
- Sørg for, at motoren er slukket og afkølet.
- Åbn brændstoftankens dæksel.
- Fill the fuel tank with fresh, unleaded gasoline (minimum 87 octane) up to the fill neck, but do not overfill. The tank capacity is 1.6 gallons.
- Luk brændstoftankens dæksel forsvarligt.
For Propane (LPG) Operation:
- Sørg for, at motoren er slukket og afkølet.
- Connect the provided LPG hose and regulator to a standard propane tank.
- Connect the other end of the LPG hose to the propane inlet on the generator's control panel.
- Sørg for, at alle forbindelser er tætte for at forhindre lækager.

Image 4.1: The generator connected to a propane tank, illustrating a dual-fuel setup.
5. Betjeningsvejledning
Follow these steps to start and operate your generator safely.
5.1 Start af generatoren
- Sørg for, at generatoren står på en plan overflade og i et godt ventileret udendørs område.
- Check engine oil level and fuel level.
- Turn the fuel selector switch to the desired fuel source (Gasoline or Propane).
- If using propane, slowly open the valve on the propane tank.
- Turn the engine switch to the 'START' position.
- Træk fast i snorstarterhåndtaget, indtil motoren starter.
- Once the engine starts, slowly move the engine switch to the 'RUN' position.
- Lad generatoren køre i et par minutter for at varme op, før du tilslutter elektriske belastninger.
5.2 Fuel Sense Technology

Image 5.1: Diagram explaining A-iPower's Fuel Sense Technology and power output for each fuel type.
The SUA4300iD features Fuel Sense Technology, which automatically switches between gasoline and propane/LPG to extend runtime. Propane is the prioritized fuel. The generator will use propane as soon as the Propane Cylinder Valve is opened. It will switch to gasoline if there is not enough propane remaining in the cylinder or if the Propane Cylinder Valve is closed.
5.3 Tilslutning af elektriske belastninger
- Ensure the generator is running smoothly.
- Plug in your electrical devices to the appropriate outlets.
- Do not overload the generator. Monitor the data center display for power output and overload indicators.
5.4 Parallel drift
This inverter generator is parallel equipped, allowing you to connect two compatible A-iPower inverter generators for increased power output. Refer to the parallel kit's instruction manual for detailed connection and operation procedures.
5.5 Nedlukning af generatoren
- Afbryd alle elektriske belastninger fra generatoren.
- If operating on propane, close the valve on the propane tank. Allow the generator to run until it consumes the remaining fuel in the line and shuts off.
- If operating on gasoline, turn the engine switch to the 'OFF' position.
- Allow the generator to cool down completely before storing.
6. Vedligeholdelse
Regelmæssig vedligeholdelse sikrer din generators levetid og pålidelige ydeevne.
6.1 Motorolie
- Kontroller oliestanden før hver brug.
- Skift olie efter de første 20 timers drift, derefter hver 100 timer eller årligt, alt efter hvad der kommer først.
6.2 Luftfilter
- Efterse luftfilteret hver 50. time eller hver 3. måned.
- Rengør eller udskift, hvis snavset.
6.3 tændrør
- Efterse tændrøret hver 100 timer eller hver 6. måned.
- Clean or replace if necessary. Ensure proper gap.
6.4 Brændstofsystem
- For gasoline, use a fuel stabilizer if storing for more than 30 days.
- Drain the carburetor and fuel tank if storing for extended periods without stabilizer.
7. Fejlfinding
Dette afsnit omhandler almindelige problemer, du kan støde på med din generator.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Motoren vil ikke starte | No fuel, low oil, spark plug issue, engine switch off, choke position incorrect | Add fuel, check oil level, inspect/clean spark plug, turn engine switch to 'ON', adjust choke |
| Ingen strømudgang | Overload, circuit breaker tripped, loose connections | Reduce load, reset circuit breaker, check connections |
| CO Sensor shutdown | Høje niveauer af kulilte registreret | Move generator to a more open, well-ventilated area. Allow to cool before restarting. |
| Motoren kører ujævnt | Stale fuel, dirty air filter, spark plug issue | Use fresh fuel, clean/replace air filter, inspect/clean spark plug |
For more detailed troubleshooting, refer to the complete owner's manual or contact customer support.
8. Specifikationer
| Feature | Specifikation |
|---|---|
| Modelnavn | SUA4300iD |
| Mærke | A-iPower |
| Motortype | 149cc OHV 4-takts |
| Starter Wattage (benzin) | 4300 watt |
| Løb Wattage (benzin) | 3450 watt |
| Starter Wattage (propan) | 3900 watt |
| Løb Wattage (propan) | 3100 watt |
| Brændstoftype | Benzin, propan |
| Tank Volume (Gasoline) | 1.6 gallons |
| Voltage | 120 volt |
| Samlet strømudtag | 3 (1x 12V DC, 1x L5-30R 120V, 1x Duplex 5-20R 120V) |
| Varens vægt | 54.8 pund |
| Produktmål (L x B x H) | 22 cm x 14.4 cm x 20.3 cm |
| Speciel funktion | Portable, Dual Fuel, Inverter, CO Sensor, Parallel Ready |
| Certificeringer | EPA, PGMA & CARB Compliant |
9. Garanti og support
9.1 Garantioplysninger
The A-iPower SUA4300iD Inverter Generator comes with a 3 års begrænset producentgaranti. Please retain your proof of purchase for warranty claims. Refer to the full warranty statement in the included owner's manual for complete terms and conditions.
9.2 Kundesupport
For any assistance, questions, or concerns regarding your A-iPower generator, please feel free to contact A-iPower customer support. Contact information can typically be found in your owner's manual or on the official A-iPower webwebsted.