Indledning
This manual provides detailed instructions for the installation, operation, and maintenance of your OREiN 2-in-1 Bathroom Exhaust Fan with Light. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.
Vigtige sikkerhedsoplysninger
Always follow basic safety precautions when installing, operating, or maintaining electrical appliances. Failure to do so may result in fire, electric shock, or injury to persons.
- Disconnect power at the service panel before wiring or servicing this unit.
- Al ledningsføring skal overholde lokale elektriske forskrifter og standarder.
- Denne enhed er kun beregnet til generel ventilation. Må ikke anvendes til udsugning af farlige eller eksplosive materialer og dampe.
- To reduce the risk of fire or electrical shock, do not expose this unit to water or moisture.
- Sørg for korrekt jording for at forhindre elektrisk stød.
- Installer ikke i et kogeområde.
- Brug altid sikkerhedsbriller og handsker under installationen.
Produkt overview og funktioner
The OREiN 2-in-1 Bathroom Exhaust Fan with Light is designed to provide efficient ventilation and illumination for your bathroom. It features a quiet operation and selectable color temperature LED lighting.

The OREiN 2-in-1 Bathroom Exhaust Fan with Light, showcasing its integrated design and the three selectable light color temperatures (3000K, 4000K, 5000K) at the bottom.

Diagram illustrating the premium materials and components, including the heavy-duty housing, powerful motor, easy installation bracket, and energy-efficient LED light.

Visual comparison demonstrating the powerful 100 CFM airflow, showing a bathroom before and after the fan effectively removes steam and humidity.

En eksploderede view of the energy-efficient and quiet DC motor, highlighting its design for ultra-quiet operation at 1.5 sones.
Nøglefunktioner:
- Høj ydeevne: Operates at 100 CFM (Cubic Feet Per Minute) for effective moisture and odor removal.
- Stille drift: Rated at 1.5 Sones for minimal noise disruption.
- Integreret LED lys: Bright 1000lm LED light illuminates your bathroom.
- 3CCT Selectable Lighting: Choose between 3000K (soft white), 4000K (bright white), or 5000K (daylight) color temperatures.
- Nightlight Funktion: Includes a 2200K nightlight for low-level illumination in the dark.
- Holdbar konstruktion: Equipped with high-quality components and a DC motor for long-lasting performance.
- Nem installation: Designed with a fast bracket for secure and straightforward installation between ceiling joists.
- Certificeringer: FCC and ETL Listed for reliability and safety.
Specifikationer

Detailed diagram showing the product dimensions, including the light cover size (10.1" x 10.1"), housing dimensions (7.68" x 7.55" x 6.42"), and recommended ceiling opening size (8.11" x 7.48").

An infographic summarizing key product specifications such as material, exhaust volume, sound level, power consumption, and color temperature options.
| Specifikation | Værdi |
|---|---|
| Modelnavn | OL17001-3CCT |
| Luftmængde kapacitet | 100 CFM |
| Støjniveau | 1.5 soner |
| Wattage | 25W (Fan) + 10W (Light) |
| Lysudgang | 1000 lm |
| Farvetemperatur | 3000K/4000K/5000K Selectable, 2200K Nightlight |
| Husets dimensioner (L x B x H) | 7.68 cm x 7.55 cm x 6.42 cm |
| Light Cover Size | 10.1 x 10.1 cm |
| Ceiling Opening Size | 8.11 x 7.48 cm |
| Voltage | 120 volt |
| Strømkilde | AC |
| Installationstype | Flush Mount |
| Certificeringer | FCC, ETL Listed |
Opsætning og installation
Before beginning installation, ensure all necessary tools and materials are available. Always disconnect power at the circuit breaker before starting any electrical work.
Værktøj og materialer (medfølger ikke):
- Skruetrækker (Phillips og Flathead)
- Trådstrippere
- Bore
- Målebånd
- Utility Kniv eller Gipsvægssav
- Duct Tape or Clamps
- Sikkerhedsbriller og handsker
Installationstrin:
- Forbered åbningen: Ensure the ceiling opening is 8.11" x 7.48". If replacing an existing fan, remove the old unit.
- Monter huset: The fan comes with a fast bracket for secure installation. Mount the bathroom fan light combo between ceiling joists using the fast bracket, or nail/screw it directly to the joist. The housing dimensions are 7.68" x 7.55" x 6.42".
- Tilslut kanalarbejde: Connect the appropriate ductwork (not included) to the fan's exhaust port. Ensure the duct does not bend into the opening to block the damper. Secure with duct tape or clamps for at forhindre luftlækager.
- Ledningsføring: Follow the wiring diagrams provided below. Ensure all connections are secure and comply with local electrical codes. This unit requires a 120V AC power source.
- Monter lysdæksel: Once wiring is complete and tested, attach the light cover (10.1'' x 10.1'') to the fan housing.

Detailed wiring diagrams for the OREiN bathroom fan, showing configurations for a single switch controlling both fan and light, and separate switches for fan and light. Includes a warning about duct obstruction.
Betjeningsvejledning
Your OREiN Bathroom Exhaust Fan with Light is designed for simple operation. The fan and light functions are typically controlled by wall switches (purchased separately).
Ventilatorbetjening:
- Turn on the wall switch connected to the fan to activate the exhaust fan.
- The fan operates at 100 CFM to effectively remove moisture and odors from the bathroom.
- Note: The fan may take a few seconds to start up. This slow start mechanism is designed to protect the DC motor and extend its lifespan.
Light Operation (3CCT Selectable & Nightlight):

Visual representation of the three selectable color temperatures: 5000K (daylight), 4000K (bright white), and 3000K (soft white).

An illustration detailing the 3CCT (3000K/4000K/5000K) and nightlight (2200K) features, including the wattage og lumenudbytte.
- Selecting Color Temperature (CCT): Before installation, locate the toggle switch on the back of the bathroom fan housing. Slide this switch to preset your desired LED color temperature: 3000K (soft white), 4000K (bright white), or 5000K (daylight). This setting is fixed once installed unless the unit is accessed again.
- Aktivering af natlys: To switch to the 2200K nightlight mode, cycle the light switch (On-Off-On) within 2 seconds. This rapid cycling will toggle between the main light and the nightlight mode.
Opretholdelse
Regular maintenance helps ensure optimal performance and extends the lifespan of your exhaust fan. Always disconnect power at the circuit breaker before performing any maintenance.
Cleaning the Light Cover:
- Carefully remove the light cover from the fan housing.
- Wipe the cover with a soft, damp cloth. Use mild soap if necessary.
- Brug ikke slibende rengøringsmidler eller opløsningsmidler, da de kan beskadige finishen.
- Ensure the cover is completely dry before reattaching.
Cleaning the Fan Housing and Motor:
- With the power off, gently vacuum or wipe away any dust or debris from the fan blades and interior of the housing.
- Do not spray water directly into the motor or electrical components.
- Sørg for, at alle dele er tørre, før du genopretter strømmen.
Fejlfinding
If you experience issues with your OREiN Bathroom Exhaust Fan with Light, refer to the following common problems and solutions. If the problem persists, contact customer support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Ventilatoren tænder ikke. | Ingen strøm til enheden. Løs ledningsforbindelse. Defekt vægafbryder. | Kontroller afbryderen og sørg for, at strømmen er tændt. Kontroller, at alle ledningsforbindelser er sikre (med strømmen slukket). Test eller udskift vægkontakten. |
| Lyset tændes ikke. | Ingen strøm til enheden. Løs ledningsforbindelse. Defekt vægafbryder. | Kontroller afbryderen og sørg for, at strømmen er tændt. Kontroller, at alle ledningsforbindelser er sikre (med strømmen slukket). Test eller udskift vægkontakten. |
| Blæseren larmer. | Blokering af kanalsystemet eller forkert installation. Løs montering. Affald i ventilatorblade. | Check ductwork for kinks or blockages. Ensure damper is not obstructed. Verify the fan housing is securely mounted to the joists. Disconnect power and clean fan blades. |
| Poor ventilation/humidity remains. | Ductwork obstruction. Fan size inadequate for room. Air leaks in ductwork. | Check ductwork for blockages or kinks. Ensure the fan's CFM rating is appropriate for your bathroom size. Seal all duct connections with appropriate tape. |
| Light color temperature is incorrect. | CCT toggle switch set incorrectly. Accidental nightlight activation. | Ensure the CCT toggle switch on the fan housing is set to your desired temperature (requires accessing the unit). Cycle the light switch (On-Off-On within 2 seconds) to toggle between main light and nightlight mode. |
Garantioplysninger
OREiN products are manufactured to high-quality standards and are warranted to be free from defects in materials and workmanship. Specific warranty terms and duration may vary. Please retain your proof of purchase for warranty claims.
For detailed warranty information or to initiate a warranty claim, please contact OREiN customer support using the information provided in the Support section.
Kundesupport
For any questions, technical assistance, or support regarding your OREiN Bathroom Exhaust Fan with Light, please contact our customer service team.
- Telefonsupport: 1(844)506-1530 (24-Hour Service)
- Online support: Contact us directly on Amazon or search for 'OREiN' online to find our official website and contact options.
- Returnerer: While returns can be processed through Amazon's logistics, we encourage you to contact us first for assistance with any issues before initiating a return.

Image showing a customer service representative and the 24-hour service phone number for support.