The Generac GP3300i inverter generator is designed to provide reliable and clean power for various applications, from outdoor adventures to essential home backup. Its advanced PowerRush™ technology offers increased starting capacity for motor-driven equipment, while its compact and lightweight design ensures portability. The unit includes multiple outlets and USB ports for versatile power delivery.
Nøglefunktioner:
- Bærbar strømløsning: Ideel til camping, tailgating, and other outdoor activities, providing stable power without excessive noise.
- High Quality and Consistent Power: TruePower Technology ensures clean power, safe for sensitive electronics, tools, and appliances.
- PowerRush Advance Technology: Delivers over 50 percent more starting capacity for tools and motor-driven equipment.
- Fuel-Efficient and Quiet: Economy Mode automatically adjusts engine speeds, reducing fuel consumption and noise.
- COsense-teknologi: Provides powerful protection against hazardous carbon monoxide by automatically shutting down the generator if CO levels become unsafe.
- Smart og pålidelig: Equipped with LED indicators for low oil, overloaded, and ready-to-use status. Features two USB ports for device charging and parallel-ready capability for doubling power output.

Figur 1.1: Forside view of the Generac GP3300i Portable Inverter Generator.

Figure 1.2: The Generac GP3300i provides portable power for camping, food trucks, DIY projects, and power outages.
2. Sikkerhedsoplysninger
Operating a generator safely is paramount. Please read and understand all safety warnings and instructions before operating this unit. Failure to follow these instructions can result in serious injury or death.
Kuliltefare:
- Generators produce carbon monoxide (CO), an odorless, colorless, and poisonous gas.
- ALDRIG operate the generator indoors, in garages, basements, crawlspaces, or other enclosed areas.
- Always operate the generator outdoors in a well-ventilated area, far away from windows, doors, and vents.
- The integrated COsense Technology will automatically shut down the generator if dangerous levels of carbon monoxide are detected. Do not disable or bypass this safety feature.
Elektrisk sikkerhed:
- Do not operate the generator in wet conditions (rain, snow, standing water).
- Ensure all electrical connections are secure and in good condition.
- Never overload the generator. Refer to the specifications for maximum wattage.
Brændstofsikkerhed:
- Gasoline is highly flammable. Store fuel in approved containers in a well-ventilated area away from ignition sources.
- Do not refuel the generator while it is running or hot. Allow it to cool down before adding fuel.
- Avoid spilling fuel. If spilled, wipe it up immediately and allow fumes to dissipate before starting the generator.
3. Opsætningsvejledning
Udpakning:
Carefully remove the generator and all accessories from the packaging. Inspect the unit for any damage that may have occurred during shipping. Retain packaging for future storage or transport.
Påfyldning af motorolie:
The generator is shipped without engine oil. It is crucial to add the correct amount and type of oil before the first start-up. Refer to the oil capacity in the specifications section.
- Placer generatoren på en plan overflade.
- Find oliepåfyldningsdækslet/målepinden.
- Using the provided funnel, slowly add the recommended engine oil (typically 10W-30 for general use) until it reaches the upper mark on the dipstick. Do not overfill.
- Sæt oliepåfyldningsdækslet/målepinden sikkert på igen.
Tilføjelse af brændstof:
Use fresh, unleaded gasoline with an octane rating of 87 or higher. Do not use E85 or any other fuel type.
- Sørg for, at generatoren er slukket og afkølet.
- Fjern brændstofdækslet.
- Carefully pour gasoline into the fuel tank, avoiding overfilling. Leave a small air gap at the top to allow for fuel expansion. The tank volume is approximately 1.06 gallons.
- Sæt brændstofdækslet sikkert på igen.
Indledende kontrol:
- Verify that the oil level is correct.
- Confirm the fuel tank is adequately filled.
- Ensure the generator is placed on a firm, level surface outdoors, away from any structures or combustible materials.
4. Betjeningsvejledning
Start af generatoren:
- Sørg for, at generatoren står på en plan overflade, og at alle elektriske belastninger er frakoblet.
- Drej brændstofventilen til 'ON'-positionen.
- Move the choke lever to the 'CHOKE' position (if the engine is cold).
- Træk fast og jævnt i rekylstarterhåndtaget, indtil motoren starter.
- Når motoren starter, skal du langsomt flytte chokerhåndtaget til 'RUN'-positionen.
Tilslutning af enheder:
The GP3300i features various outlets for connecting your devices:
- Duplex Outlets: Standard 120V AC outlets for general appliances.
- 30A Twistlock Outlet: For higher power demands, such as RVs.
- USB-porte: To USB-porte til opladning af mobile enheder.
Once the generator is running stably, you can plug in your electrical devices. Always ensure the total wattagstrømforbruget af tilsluttede enheder overstiger ikke generatorens driftsvandtage (2500 Watts) or starting wattage (3300 watt).

Figure 4.1: The control panel highlights PowerRush technology, ultra-quiet operation, and convenient USB ports.
Økonomitilstand:
Activate Economy Mode to automatically adjust engine speed to match the load. This reduces fuel consumption and noise levels when full power is not required. The generator will automatically rev up when more power is needed.
Parallel drift:
The GP3300i is parallel-ready, allowing you to connect two compatible Generac inverter generators together using a parallel kit (sold separately) to double your power output. Refer to the parallel kit's instructions for proper connection.
Stop generatoren:
- Afbryd alle elektriske belastninger fra generatoren.
- Lad generatoren køre i et par minutter uden belastning for at køle af.
- Drej motorkontakten til 'OFF'-positionen.
- Drej brændstofventilen til 'OFF'-positionen for opbevaring.
5. Vedligeholdelse
Regular maintenance is essential for the longevity and optimal performance of your Generac GP3300i generator. Always ensure the generator is off and cool before performing any maintenance.
Regelmæssig kontrol:
- Før hver brug skal du kontrollere motoroliestanden og brændstofstanden.
- Inspect the air filter for dirt or debris.
- Check for any loose fasteners or damaged components.
Olieskift:
Perform the first oil change after the initial 20 hours of operation, and then every 50-100 hours or annually, whichever comes first. Refer to the engine oil specifications for type and capacity.
Rengøring/udskiftning af luftfilter:
Inspect the air filter regularly (every 25-50 hours or more frequently in dusty conditions). Clean or replace as necessary to ensure proper engine performance.
Tændrørsinspektion:
Inspect the spark plug every 100 hours or annually. Clean or replace if it is fouled, worn, or damaged. Ensure the correct gap is maintained.
Opbevaring:
If storing the generator for more than 30 days, it is recommended to drain the fuel system or use a fuel stabilizer to prevent fuel degradation. Store the generator in a clean, dry place.
6. Fejlfinding
This section provides solutions to common operational issues. For problems not listed here or if solutions do not resolve the issue, contact Generac customer support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Motoren vil ikke starte | No fuel; Low oil level; Choke not set correctly; Spark plug issue; Stale fuel | Add fuel; Add oil; Adjust choke; Inspect/replace spark plug; Drain and refill with fresh fuel |
| Ingen strømudgang | Overload; Circuit breaker tripped; ECO mode engaged with high load; Faulty connection | Reduce load; Reset circuit breaker; Turn off ECO mode for high loads; Check connections |
| Motoren går ujævnt/går i stå | Dirty air filter; Stale fuel; Clogged fuel filter; Spark plug issue | Clean/replace air filter; Drain and refill with fresh fuel; Replace fuel filter; Inspect/replace spark plug |
| Overload indicator light on | Generatoren er overbelastet | Disconnect all loads, turn off generator, restart, and reconnect loads one by one, ensuring total wattage er inden for grænserne. |
7. Tekniske specifikationer
Detailed specifications for the Generac GP3300i Portable Inverter Generator.
| Specifikation | Værdi |
|---|---|
| Modelnavn | GP3300i |
| Modelnummer | 7153 |
| Starter Wattage | 3300 watt |
| Løb Wattage | 2500 watt |
| Brændstoftype | Benzin |
| Tankvolumen | 1.06 gallons |
| Køretid (ved 50% belastning) | 4.5 timer (ca.) |
| Motortype | 4 takt |
| Motorens slagvolumen | 149 kubikcentimeter |
| Voltage | 120 volt |
| Frekvens | 60 Hz |
| Varens vægt | 26.99 pund (ca. 59.5 lbs) |
| Produktmål (L x B x H) | 22.2 cm x 13.4 cm x 18.4 cm |
| Samlet strømudtag | 2 (plus USB ports) |
| Speciel funktion | CO Sensor, Portable |
| UPC | 696471086263 |

Figure 7.1: Key dimensions and wattage ratings for the Generac GP3300i.

Figur 7.2: En vejledning til typiske løbe- og startvanertage requirements for various devices.
8. Garanti og support
Generac stands behind the quality of its products. The GP3300i Portable Inverter Generator typically comes with a limited warranty.
Garantioplysninger:
- 1 år: Dele og arbejdskraft
- 3 år: Kun dele
Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Generac warranty statement included with your product or visit the Generac webwebsted.
Kundesupport:
For technical assistance, parts, or service, please contact Generac customer support. Have your model number (7153) and serial number ready when contacting support to expedite service.