1. Introduktion
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Senville AURA Series Mini Split Air Conditioner Heat Pump. Please read this manual thoroughly before operating the unit to ensure proper use and to prevent damage.
The Senville AURA Series is designed to provide efficient cooling and heating for various spaces, including individual rooms, additions, garages, and commercial applications. It features DC Inverter Technology for high efficiency and quiet operation.

Figure 1.1: Complete Senville AURA Series Mini Split System Components.
2. Sikkerhedsoplysninger
Always adhere to the following safety precautions to reduce the risk of fire, electric shock, injury, or property damage.
- Installation must be performed by qualified personnel in accordance with all applicable local and national codes.
- Sørg for, at strømforsyningen stemmer overens med enhedens specifikationer (208-230V).
- Stik ikke fingre eller genstande ind i luftindtaget/-udtaget.
- Forsøg ikke at reparere enheden selv. Kontakt kvalificeret servicepersonale.
- Turn off the power supply before cleaning or performing maintenance.
3. Produktkomponenter
The Senville AURA Series SENA-48HF/F system includes the following main components:
- (5) 9000 BTU Indoor Air Handlers
- (1) 48000 BTU Outdoor Condenser
- Trådløse fjernbetjeninger (én til hver indendørsenhed)
- Pre-charged refrigerant lines (up to 125 ft)
- Installation accessories (drain hoses, electrical wiring, insulation tape)

Figure 3.1: Indoor Air Handler Unit.

Figur 3.2: Trådløs fjernbetjening.

Figure 3.3: Included Installation Accessories.
4. Installation og opsætning
Installation of the Senville AURA Series mini split system requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC technician.
4.1 Tjekliste før installation
- Kontroller, at alle komponenter er til stede og ubeskadigede.
- Ensure adequate space for indoor and outdoor units, allowing for proper airflow and maintenance access.
- Confirm electrical supply meets 208-230V requirements and dedicated circuit is available.
4.2 Installationstrin (Overview for tekniker)
- Mount indoor air handlers in desired locations, ensuring proper drainage.
- Position the outdoor condenser unit on a stable, level surface, away from obstructions.
- Connect refrigerant lines between indoor and outdoor units. The system is pre-charged for up to 125 feet of line.
- Connect electrical wiring according to the wiring diagram provided in the full installation manual.
- Perform vacuuming of the refrigerant lines to remove air and moisture.
- Check for leaks using appropriate methods.
- Open service valves to release refrigerant.
- Test the system for proper operation in both cooling and heating modes.
5. Betjeningsvejledning
Your Senville AURA Series system is designed for user-friendly operation via the wireless remote control.
5.1 Fjernbetjeningsfunktioner
Refer to Figure 3.2 for a visual guide to the remote control buttons.
- Power knap: Tænder/slukker enheden.
- Mode knap: Skifter mellem driftstilstande: Auto, Køling, Tørring, Varme, Ventilator.
- Temperaturjustering: Use UP/DOWN arrows to set desired temperature.
- Blæserhastighed: Justerer ventilatorhastigheden (Auto, Lav, Mellem, Høj).
- Svinge: Controls the louver swing for air distribution.
- ECO Gear: Aktiverer energisparetilstand.
- Timer: Indstiller ON/OFF-timere for planlagt drift.
5.2 driftstilstande
- Cool tilstand: Provides cooling. Ideal for summer months.
- Varmetilstand: Provides heating. Effective down to -22°F (-30°C) with Arctic Heat Pump technology.
- Tør tilstand: Affugter luften.
- Ventilatortilstand: Cirkulerer luft uden opvarmning eller afkøling.
- Automatisk tilstand: Automatically selects cooling or heating based on ambient temperature.

Figure 5.1: Operating Temperature Range.
5.3 Smarte funktioner
- Whisper Technology: Ensures quiet operation, with noise levels as low as 23.5 dB.
- Smart Saving: Built-in intelligent eye detects human movement to automatically adjust operation and save energy.
- Smart kontrol: Compatible with voice control (e.g., Alexa) and app control (requires Alexa Kit installation).

Figure 5.2: Low Noise Operation.

Figure 5.3: Smart Saving Feature.

Figure 5.4: Smart Controls with Alexa Integration.
6. Vedligeholdelse
Regular maintenance ensures optimal performance and longevity of your Senville AURA system.
6.1 Filterrensning
- Clean air filters every two weeks or more frequently depending on usage and air quality.
- Open the front panel of the indoor unit, remove filters, and wash with lukewarm water.
- Lad filtrene tørre helt, før de sættes i igen.
6.2 Vedligeholdelse af udendørsenhed
- Hold området omkring udendørsenheden fri for snavs, blade og sne.
- Periodically clean the outdoor coil with a soft brush or vacuum cleaner.
- Ensure proper drainage from the outdoor unit.
6.3 Professionel service
It is recommended to have a certified HVAC technician perform annual inspections and maintenance, including checking refrigerant levels, electrical connections, and overall system performance.
7. Fejlfinding
Før du kontakter kundesupport, bedes du læse følgende almindelige problemer og løsninger:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | Ingen strøm, fjernbetjeningens batterier døde, afbryderen er udløst. | Kontroller strømforsyningen, udskift fjernbetjeningens batterier, nulstil afbryderen. |
| Utilstrækkelig køling/opvarmning. | Snavsede luftfiltre, blokeret udendørsenhed, forkert indstilling af tilstand, lavt kølemiddelniveau. | Clean filters, clear obstructions, select correct mode, contact technician for refrigerant check. |
| Usædvanlig støj. | Loose parts, fan obstruction, normal operating sounds (e.g., refrigerant flow). | Inspect for loose parts, remove obstructions. If persistent or loud, contact technician. |
| Vandlækage fra indendørsenheden. | Tilstoppet afløbsslange, forkert installation. | Check and clear drain hose. If issue persists, contact technician. |
8. Tekniske specifikationer
| Feature | Specifikation |
|---|---|
| Modelnummer | SENA-48HF/F |
| Kapacitet | 48000 BTU (4 tons) |
| Indendørs enheder | (5) 9000 BTU Air Handlers |
| Udendørsenhed | (1) 48000 BTU Condenser |
| Voltage | 208-230 volt |
| Effektivitet (SEER) | 22.0 |
| Støjniveau (indendørs) | 23.5 dB (Whisper Technology) |
| Produktdimensioner | 48"D x 48"W x 60"H (Overall System) |
| Særlige funktioner | Heating and Cooling Function, DC Inverter Technology, Smart Saving, Smart Controls (Alexa compatible) |
| Certificeringer | ETL Intertek Approved, AHRI Certified, ENERGYSTAR |
9. Garantioplysninger
The Senville AURA Series is backed by a comprehensive warranty:
- Dele garanti: 5 år
- Kompressor garanti: 10 år
For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Senville webwebsted.
10. Kundesupport
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Senville customer support.
- Webwebsted: Visit the Senville Store on Amazon
- Generelle forespørgsler: Refer to the contact information provided in your product packaging or on the official Senville webwebsted.

Figure 10.1: Senville Customer Support.