1. Produktet er slutview
The KKnoon 150W 20A Adjustable Constant Current Electronic Load is a versatile direct current (DC) electronic load device designed for testing power supplies, batteries, and other DC sources. It features a 2.4-inch TFT color display for real-time monitoring of various parameters and supports four distinct working modes. This manual provides detailed instructions for its setup, operation, and maintenance.

Figure 1: KKnoon 150W 20A Electronic Load with included accessories.
2. Sikkerhedsoplysninger
- Ensure the device is powered by a 12VDC, 1A power adapter.
- Do not exceed the maximum load voltage of 150VDC, load current of 20A, or load power of 150W (max. 60W above 120V).
- Always connect the load correctly using the four-wire system for accurate measurements.
- Avoid touching internal components when the device is powered on.
- Brug i et godt ventileret område for at forhindre overophedning.
3. Pakkens indhold
Bekræft at alle varer er til stede i pakken:
- 1 x Electronic Load Unit
- 1 x 12VDC Power Adapter
- 1 x NTC Temperature Sensor
4. Enhedslayout og tilslutninger
Familiarize yourself with the main components and connection points of the electronic load.

Figure 2: Key components of the Electronic Load.
- Operating Power Supply DC Interface: Connect the provided 12VDC, 1A power adapter here.
- Køleventilator: Automatically activates when internal temperature reaches ≥40°C or current exceeds 3A.
- Kontroltaster: Used for navigation, setting parameters, and turning the load ON/OFF.
- 2.4-tommer skærm: TFT color screen showing all operational parameters and settings.
- Input 4P Terminal Block: For connecting the device under test (DUT). Supports four-wire (A+, V+, V-, A-) and two-wire systems.

Figur 3: Detaljeret view of the four-wire terminal block and NTC sensor interface.
5. Opsætning og ledningsføring
Proper wiring is crucial for accurate measurements and safe operation.
5.1 Strømforsyning til enheden
- Connect the provided 12VDC, 1A power adapter to the DC input jack (1) on the electronic load.
- Plug the adapter into a suitable power outlet. The display should illuminate.
5.2 Connecting the Load (Device Under Test)
The electronic load supports both four-wire and two-wire connection methods. The four-wire method provides more accurate voltage measurement by separating the voltage sensing lines from the current carrying lines.

Figure 4: Wiring diagrams for four-wire and two-wire connections.
- Four-Wire System: Connect the positive terminal of the DUT to A+ and the negative terminal to A- for current flow. Additionally, connect a separate pair of wires from the positive terminal of the DUT to V+ and the negative terminal to V- for bindtage sensing. This method compensates for voltage drop across the current wires.
- Two-Wire System (Downward Compatible): Connect the positive terminal of the DUT to A+ and the negative terminal to A-. In this configuration, the V+ and V- terminals are internally shorted to A+ and A- respectively. Note that voltage readings may be slightly less accurate due to voltage drop in the current wires.
5.3 Connecting the NTC Temperature Sensor
- Plug the NTC 3950 10K 1% temperature sensor into the dedicated NTC interface next to the 4P terminal block (refer to Figure 3).
- Place the sensor in contact with the component or area whose temperature you wish to monitor (e.g., battery surface). The device will display temperatures from 0-100°C.
6. Betjeningsvejledning
The electronic load features a 2.4-inch TFT color display and control buttons for easy operation.

Figure 5: Control buttons for operation.
6.1 Display overview
The 2.4-inch TFT color screen displays real-time values for:
- Voltage (V)
- Nuværende (A)
- Effekt (W)
- Cumulative Energy (Wh)
- Cumulative Capacity (Ah)
- Internal Resistance (Ω)
- Load Status (ON/OFF)
- Operating Mode (CC, CV, CP, CR)
- Protection Status (OVP, OCP, OPP)
- Stop lydstyrketage
- Time Limit Discharge
- External Temperature (if NTC sensor connected)
6.2 Betjeningsknapper
- TIL/FRA: Toggles the electronic load ON or OFF.
- '-' (Minus): Decreases parameter values or navigates menu options.
- '+' (Plus): Increases parameter values or navigates menu options.
- SÆT: Enters parameter setting mode, confirms selections, or switches between display pages.
6.3 Arbejdstilstande
The device supports four primary working modes:
- CC (Constant Current) Mode: Maintains a constant discharge current regardless of voltage changes. Ideal for battery capacity testing.
- CV (Constant Voltage) Mode: Opretholder et konstant volumentage across the load.
- CP (Constant Power) Mode: Maintains a constant power dissipation.
- CR (Constant Resistance) Mode: Maintains a constant resistance.
For at vælge en arbejdstilstand:
- Tryk på SÆT button to enter the main menu or parameter setting interface.
- Brug '+' or '-' buttons to navigate to the 'Mode' option.
- Trykke SÆT to select, then use '+' or '-' to choose the desired mode (CC, CV, CP, CR).
- Trykke SÆT again to confirm the mode selection.
6.4 Indstilling af parametre
After selecting a working mode, you can set its specific parameters (e.g., target current for CC mode, target voltage for CV mode).
- In the desired working mode, press SÆT to highlight the parameter you wish to adjust.
- Bruge '+' or '-' to change the value. A long press may accelerate value changes.
- Trykke SÆT again to confirm the value and move to the next parameter or exit setting mode.
6.5 Beskyttelsesindstillinger
The device includes several protection features to prevent damage to the DUT or the electronic load itself.
- Overvoltage-beskyttelse (OVP): Supports up to 150V. Set the maximum allowable input voltage.
- Overstrømsbeskyttelse (OCP): Supports up to 20A. Set the maximum allowable current draw.
- Over-power Protection (OPP): Supports up to 150W. Set the maximum allowable power dissipation.
- Begrænset bindtage Discharge (Low Voltage beskyttelse): Allows setting a minimum discharge voltage. If the DUT voltage drops below this threshold, the load will stop. Default is unlimited; set according to your needs.
- Time Limit Discharge: Supports discharge duration up to 99 hours and 59 minutes. The load will stop automatically after the set time.
To set protection parameters, navigate through the menu using the SÆT, '+', og '-' knapper.
6.6 Andre indstillinger
- Chinese and English Interface Switching: Supported. Navigate to the language setting in the menu.
- Zeroing of Total Data: Resets cumulative energy (Wh) and capacity (Ah) measurements.
- Voltage and Current No-Load Nulling: Calibrates the zero point for voltage and current readings when no load is connected.
- Voltage Open Calibration: Allows for fine-tuning voltage målenøjagtighed.
- Current Open Calibration: Allows for fine-tuning current measurement accuracy.
- Justering af skærmens lysstyrke: Adjust display brightness for optimal visibility.
- Screen Hibernation Standby Setting: Configures display standby behavior.
- Gendan fabriksindstillinger: Resets all parameters to their default values.
7. Vedligeholdelse
- Hold enheden ren og fri for støv. Brug en blød, tør klud til rengøring.
- Ensure proper ventilation around the device, especially the cooling fan, to prevent overheating.
- Opbevar enheden et tørt sted, væk fra direkte sollys og ekstreme temperaturer.
- Do not attempt to disassemble the device beyond what is necessary for sensor connection or cleaning, as this may void the warranty.
8. Fejlfinding
- Enheden tændes ikke: Check if the 12VDC power adapter is correctly connected and functioning. Ensure the power outlet is active.
- Ingen belastningsstrøm/volumentage reading: Verify that the DUT is properly connected to the 4P terminal block (A+, A-, V+, V-). Ensure the DUT is powered on and supplying voltage. Check if the load is enabled (ON/OFF button).
- Load stops unexpectedly: Check if any protection (OVP, OCP, OPP, Low Voltage Protection, Time Limit Discharge) has been triggered. Adjust protection limits if necessary.
- Unøjagtige aflæsninger: Udfør voltage and current open calibration. Ensure a four-wire connection is used for maximum accuracy.
- Cooling fan not running: The fan activates automatically when the internal temperature reaches ≥40°C or current exceeds 3A. If these conditions are met and the fan is still not running, contact support.
9. Specifikationer
| Parameter | Værdi |
|---|---|
| Belastningstype | CNC Electronic Load |
| Working Voltage | 12VDC (with 12V, 1A power adapter) |
| Indlæs VoltagRækkevidde | 0-150VDC |
| Load Current Range | 0-20A |
| Belastningseffektområde | 0-150W (max. 60W above 120V) |
| Forbindelsesmetode | A+ V+ V- A- four-wire system, downward compatible with two-wire system |
| Max Power Measurement | 999.999Wh |
| Max Capacity Measurement | 999.999 Ah |
| Cumulative Timing Range | ddd:hh:mm:ss (days:hours:minutes:seconds) |
| Driftstilstande | CC (konstant strøm), CV (konstant volumen)tage), CP (Constant Power), CR (Constant Resistance) |
| Overvoltage Beskyttelse | Supports up to 150V |
| Overstrømsbeskyttelse | Supports up to 20A |
| Overbelastningsbeskyttelse | Understøtter op til 150W |
| Begrænset bindtage Discharge | Supported (low voltage protection, default unlimited) |
| Time Limit Discharge | Supports up to 99 hours: 59 minutes |
| Heat Sink | Alloy integrated silent heat sink, automatic operation ≥40°C or >3A |
| Ekstern temperaturmåling | NTC 3950 10K 1% sensor, 0-100°C |
| Interface sprog | Chinese and English switching supported |
| PC Software Online | Ikke understøttet |
| Pakkedimensioner | 7.83 x 5.55 x 4.29 tommer |
| Pakkevægt | 1.3 pund (625 g) |
10. Garanti og support