Salicru SLC-2000-TWIN RT3

Salicru SLC-2000-TWIN RT3 UPS Brugermanual

Model: SLC-2000-TWIN RT3 | Brand: Salicru

1. Introduktion og overview

The Salicru SLC-2000-TWIN RT3 is an On-Line Double Conversion Uninterruptible Power Supply (UPS) designed to provide reliable power protection for critical systems. This model, with a capacity of 3000VA / 2000W, offers high operational efficiency and an optimized battery charging system. Its versatile design allows for both 2U rack and tower installations, adapting to various environmental needs. Key features include an output power factor of 1, a rotatable Dot Matrix display for easy monitoring, and options for extended autonomy.

2. Sikkerhedsoplysninger

Læs alle sikkerhedsinstruktioner omhyggeligt, inden du installerer, betjener eller servicerer UPS'en. Manglende overholdelse af disse instruktioner kan resultere i elektrisk stød, brand eller alvorlig personskade.

  • Elektrisk sikkerhed: Denne enhed indeholder farlige voltagÅbn ikke UPS-kabinettet. Service bør kun udføres af kvalificeret personale.
  • Batterisikkerhed: The UPS contains sealed lead-acid batteries. Do not dispose of batteries in a fire, as they may explode. Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes.
  • Miljø: Install the UPS in a well-ventilated area, free from excessive dust, corrosive fumes, and conductive contaminants. Avoid direct sunlight and heat sources.
  • Vægt: The UPS unit is heavy. Use proper lifting techniques and ensure adequate support during installation.

3. Pakkens indhold

Kontroller, at alle dele er til stede i pakken. Hvis der mangler dele eller er beskadiget, skal du straks kontakte din forhandler.

  • Salicru SLC-2000-TWIN RT3 UPS Unit
  • Brugervejledning (dette dokument)
  • Strømindgangskabel
  • Udgangsstrømkabler (antallet kan variere)
  • Rack Mount Kit (rails, brackets, screws)
  • Tower Stand (for vertical orientation)
  • Communication Cables (USB, RS232)

4. Fysisk beskrivelse og komponenter

The SLC-2000-TWIN RT3 features a robust design with a front panel display and controls. Its convertible form factor allows for flexible deployment.

Salicru SLC-2000-TWIN RT3 UPS in rackmount configuration

Figur 4.1: Forside view of the Salicru SLC-2000-TWIN RT3 UPS in a rackmount configuration, showing the display and control buttons.

Close-up of the Salicru UPS front panel display

Figur 4.2: Detaljeret view of the UPS front panel, highlighting the Dot Matrix display and navigation buttons (ESC, Up, Down, Enter).

Salicru UPS with an external battery module

Figure 4.3: The Salicru UPS unit stacked with an optional external battery module, demonstrating extended autonomy capability.

Salicru UPS in both rack and tower configurations with monitoring software

Figure 4.4: The UPS shown in both horizontal (rack) and vertical (tower) orientations, alongside a depiction of its monitoring software interface on various devices.

4.1 Frontpanel

  • Dotmatrix-display: Provides real-time status, input/output voltage, load level, battery status, and alarm messages. The display can be rotated for optimal viewing in both rack and tower configurations.
  • Kontrolknapper: Used for navigating menus, confirming selections, and controlling UPS functions (e.g., ESC, Up, Down, Enter/Power).

4.2 Bagpanel

The rear panel typically includes input power connectors, output receptacles (identified by color for different functions), communication ports (USB, RS232, SNMP slot), and an external battery connector.

5. Opsætning og installation

Follow these steps for proper installation of your Salicru UPS.

5.1 Valg af placering

Select a location that meets the environmental requirements mentioned in Section 2. Ensure sufficient clearance for ventilation and access to the front and rear panels.

5.2 Rackmount or Tower Configuration

The UPS can be installed in a standard 19-inch rack or as a standalone tower unit.

  • Rackmontering: Attach the provided rackmount ears and rails to the UPS and then secure it into the server rack.
  • Tårn: Attach the provided tower stand to the base of the UPS for vertical stability. Ensure the display orientation is adjusted as needed.

5.3 Tilslutning af UPS'en

  1. Tilslut indgangsstrøm: Connect the UPS input power cable to a grounded electrical outlet.
  2. Tilslut udstyr: Plug your critical equipment (servers, network devices, etc.) into the output receptacles on the rear panel of the UPS. Observe the power ratings of the UPS and your connected devices.
  3. Tilslut kommunikationskabler: For monitoring and management, connect the USB or RS232 cable from the UPS to your computer or server. Install the monitoring software if desired.
  4. External Battery Modules (Optional): If using external battery modules, connect them to the designated port on the UPS rear panel. The UPS features an automatic detection system for these modules.

5.4 Første opstart

  1. Sørg for, at alle forbindelser er sikre.
  2. Press and hold the power button on the front panel until the UPS powers on.
  3. The display will show the startup sequence and then the current operating status.
  4. Allow the UPS to charge its internal batteries for at least 8 hours before relying on it for extended backup.

6. Betjeningsvejledning

The Salicru SLC-2000-TWIN RT3 operates in On-Line Double Conversion mode, providing continuous, clean power to connected equipment.

6.1 Display og navigation

The Dot Matrix display provides comprehensive information. Use the navigation buttons (ESC, Up, Down, Enter) to scroll through menus and adjust settings. Refer to the detailed menu structure in the full manual for specific options.

6.2 Normal drift

During normal operation, the UPS continuously converts incoming AC power to DC to charge the batteries and then converts it back to clean AC power for your connected devices. This isolates your equipment from utility power fluctuations.

6.3 Batteritilstand

I tilfælde af en magt outage, the UPS automatically switches to battery power, providing uninterrupted power to your connected equipment. The display will indicate battery mode and remaining runtime.

6.4 Nedlukning

To safely shut down the UPS, press and hold the power button until the unit powers off. Ensure all connected equipment is also properly shut down before disconnecting the UPS from the power source.

7. Vedligeholdelse

Regelmæssig vedligeholdelse sikrer din UPS' levetid og optimal ydeevne.

  • Batteripleje: The UPS features an improved 8A charger with a

    Relaterede dokumenter - SLC-2000-TWIN RT3

    Preview Salicru SLC TWIN RT3 LION Lynstartguide
    Lynstartguide til Salicru SLC TWIN RT3 LION-serien af ​​afbrydelsesfri strømforsyninger (UPS), der dækker installation, tilslutning og grundlæggende betjening af modellerne 1000, 1500, 2000 og 3000 VA.
    Preview Brugervejledning Salicru SLC TWIN RT3: Sistemas de Alimentación Ininterrumpida (SAI)
    Fuldfør installation, drift og mantenimiento for Ininterrumpida Alimentación (SAI) Salicru SLC TWIN RT3. Kuberkarakteristika, funktionsmåder, problemløsning og tekniske tekniske detaljer.
    Preview Brugervejledning Salicru SLC TWIN RT3 LION UPS (1-3 kVA)
    Hent den komplette brugsvejledning til Salicru SLC TWIN RT3 LION, et system til interrumpida alimentation (SAI/UPS) på 1 til 3 kVA. Inkluderer installations-, betjenings- og mantenimiento-instruktioner.
    Preview Brugervejledning Salicru SLC TWIN RT2: UPS fra 0,7 til 10 kVA
    Manuel komplet til installation, betjening og mantenimiento af Los Sistemas de Alimentación Ininterrumpida (SAI) Salicru SLC TWIN RT2, med kraft på 0,7 til 10 kVA. Inkluye especificaciones técnicas and guías de solución de problemas.
    Preview Salicru SLC TWIN PRO2 T UL UPS brugermanual (6 & 10 kVA)
    Omfattende brugermanual til Salicrus SLC TWIN PRO2 T UL-serie af afbrydelsesfri strømforsyninger (UPS), der dækker 6 og 10 kVA modeller. Indeholder vejledning i installation, drift, sikkerhed, vedligeholdelse og fejlfinding.
    Preview Salicru Make Before Break Manuel Bypass Panel Brugermanual til UPS-systemer
    Denne brugermanual indeholder detaljerede instruktioner til installation, betjening og nedlukning af Salicru Make Before Break manuelle bypasspaneler designet til forskellige UPS-systemer, herunder SLC ADAPT, SLC CUBE 3+, SLC TWIN PRO2, SLC TWIN PRO 33 og SLC X-TRA.