LFF Atomur LWC205 Brugermanual
Model: LWC205
Digital Wall Clock with Indoor/Outdoor Temperature and Wireless Sensor
1. Introduktion
Tak for købetasing the LFF Atomic Clock LWC205. This digital clock features a large, easy-to-read display, atomic time synchronization, indoor and outdoor temperature monitoring, and an alarm function. This manual provides detailed instructions for setup, operation, maintenance, and troubleshooting to ensure optimal performance of your device.

Image 1.1: The LFF Atomic Clock LWC205 main unit and its accompanying wireless outdoor sensor.
2. Produktet er slutview
2.1 Displayelementer

Image 2.1: Detailed diagram illustrating the various display elements and control buttons on the LFF Atomic Clock LWC205. Key features include the alarm clock icon, time display, RCC reception icon, DST symbol, outdoor temperature, indoor temperature, date, and weekday.
2.2 Control Buttons (Rear View)
The control buttons are located on the back of the main clock unit:
- SET -knap: Bruges til at indtaste og bekræfte indstillinger.
- ALARM knap: Used to set and activate/deactivate the alarm.
- KANAL-knap: Used to select the outdoor sensor channel (if multiple sensors are used).
- DOWN/WAVE/°C/°F Button: Used to decrease values during setting, manually initiate atomic time synchronization (wave), or switch between Celsius and Fahrenheit.
- UP/ALARM Button: Used to increase values during setting or activate/deactivate the alarm.
3. Opsætning
3.1 Udpakning
Carefully remove all components from the packaging. Ensure you have the main atomic clock unit and the wireless outdoor sensor.
3.2 Batteriinstallation
Both the main clock unit and the wireless outdoor sensor require batteries (not included).
- Main Clock Unit: Open the battery compartment on the back of the clock. Insert 3 x AA batterier, hvilket sikrer korrekt polaritet (+/-).
- Trådløs udendørs sensor: Open the battery compartment on the back of the sensor. Insert 2 x AAA batterier, ensuring correct polarity (+/-). For temperatures below -4°F (-20°C), lithium batteries are recommended for the outdoor sensor.

Image 3.1: Instructions for installing 3xAA batteries in the main clock unit and 2xAAA batteries in the wireless outdoor sensor.
3.3 Sensorplacering
Place the wireless outdoor sensor in a shaded, dry location away from direct sunlight and precipitation. The sensor has a wireless range of up to 330 feet (100 meters) from the main unit. Ensure there are no major obstructions between the sensor and the clock for optimal signal transmission.

Image 3.2: Illustration of the 330ft wireless range between the main clock unit and the outdoor temperature sensor.
3.4 Clock Placement
The LFF Atomic Clock LWC205 offers two placement options:
- Table Clock: Use the integrated stand on the back of the unit to place it on a desk, nightstand, or shelf.
- Wall Clock: Utilize the keyhole slot on the back of the unit to mount it securely on a wall.

Image 3.3: The LFF Atomic Clock can be placed on a table using its built-in stand or mounted on a wall.
4. Betjeningsvejledning
4.1 Atomic Time Synchronization (WWVB)
The clock automatically synchronizes with the WWVB radio broadcast from Fort Collins, Colorado, ensuring accurate time. This process typically occurs overnight. For best reception, place the clock near a window and away from electronic interference.

Image 4.1: The atomic clock automatically corrects its time daily by receiving the WWVB signal, covering eight time zones and adjusting for Daylight Saving Time.
4.2 Manuel indstilling af tid og dato
In areas where the WWVB signal is weak or unavailable, you can manually set the time and date:
- Tryk og hold på SÆT knappen for at gå ind i tidsindstillingstilstand.
- Brug UP or NED knapper til at justere den blinkende værdi (f.eks. time, minut, år, måned, dag).
- Tryk på SÆT knappen for at bekræfte hver indstilling og gå videre til den næste.
- The clock will exit setting mode automatically after a few seconds of inactivity or by pressing SÆT repeatedly until all settings are confirmed.
4.3 Temperaturvisning (°C/°F)
The clock displays both indoor and outdoor temperatures. To switch between Celsius (°C) and Fahrenheit (°F):
- Tryk på DOWN/WAVE/°C/°F button to toggle the temperature unit.
4.4 12/24 timers format
Sådan skifter du mellem 12-timers og 24-timers tidsformater:
- Tryk på UP -knappen for at skifte mellem 12-timers (med AM/PM-indikator) og 24-timers formater.
4.5 Alarmfunktion
Sådan indstilles alarmen:
- Tryk på ALARM knappen én gang for at vise det aktuelle alarmtidspunkt.
- Tryk og hold på ALARM knappen for at gå ind i alarmindstillingstilstand.
- Brug UP or NED knapper til at justere time og minut.
- Tryk på ALARM knappen for at bekræfte hver indstilling.
For at aktivere/deaktivere alarmen:
- Tryk på ALARM button repeatedly to cycle through alarm ON/OFF states. An alarm icon will appear on the display when activated.
5. Vedligeholdelse
5.1 Udskiftning af batteri
When the low battery indicator appears on the display, replace the batteries in the respective unit (main clock or outdoor sensor) promptly to ensure continuous operation and accurate readings. Refer to Section 3.2 for battery types and installation.
5.2 Rengøring
Clean the clock and sensor with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the display or casing.
5.3 Miljøhensyn
The outdoor sensor is designed for outdoor use but should be protected from extreme weather conditions. The recommended operating temperature range for the outdoor sensor is -58°F to 158°F (-50°C to 70°C). For temperatures below -4°F (-20°C), lithium batteries are required in the outdoor sensor for reliable performance.
6. Fejlfinding
- Ingen visning / Svag visning: Check battery installation and replace with fresh batteries if necessary. Ensure correct polarity.
- Ingen udetemperaturmåling:
- Ensure batteries are correctly installed in the outdoor sensor.
- Verify the sensor is within the 330ft wireless range of the main unit.
- Tryk på KANAL button on the main unit to ensure it is on the correct channel (if applicable).
- Relocate the sensor or main unit to improve signal reception, avoiding large metal objects or other electronic devices.
- Forkert tidspunkt:
- Ensure the clock is attempting to receive the WWVB signal (look for the RCC reception icon).
- Place the clock near a window and away from electronic interference for better signal reception.
- Manually initiate a signal search by pressing the DOWN/WAVE knap.
- If atomic synchronization fails, manually set the time as described in Section 4.2.
- Temperature Readings Seem Inaccurate:
- Ensure the outdoor sensor is placed in a shaded area, away from direct sunlight or heat sources.
- Kontroller batteriniveauet i begge enheder.
7. Specifikationer
| Feature | Detalje |
|---|---|
| Mærke | LFF forlængelse |
| Modelnummer | LWC205 |
| Display Type | Digital |
| Farve | Sølv |
| Speciel funktion | Atomic Time, Indoor/Outdoor Temperature, Alarm |
| Produktdimensioner | 7.48 cm B x 8.66 cm H |
| Power Source (Clock) | 3 x AA batterier (medfølger ikke) |
| Strømkilde (sensor) | 2 x AAA batterier (medfølger ikke) |
| Indendørs/Udendørs brug | Indoor (Clock), Outdoor (Sensor) |
| Udendørs temperaturområde | -58°F til 158°F (-50°C til 70°C) |
| Indendørs temperaturområde | 32°F til 122°F (0°C til 50°C) |
| Trådløs sensorrækkevidde | Op til 330 fod (100 meter) |
| Monteringstype | Vægmontering, bordplade |
| Materiale | Acrylonitril Butadien Styren (ABS) Plast |
| Varens vægt | 0.9 pund (14.4 ounce) |
8. Garantioplysninger
Warranty information was not provided in the product data. Please refer to the product packaging or contact the manufacturer directly for details regarding warranty coverage and terms.
9. Kundesupport
For further assistance or inquiries, please contact LFF customer support. Contact details were not provided in the product data. Please refer to the product packaging or the official LFF webhjemmeside for kontaktoplysninger til kundeservice.





