1. Sikkerhedsoplysninger

Please read all safety warnings and instructions carefully before installing, operating, or performing maintenance on this appliance. Failure to follow these instructions may result in serious injury or property damage.

  • Elektrisk sikkerhed: Ensure the appliance is connected to a properly grounded power supply with the correct voltage and current rating. Do not use extension cords or adapters. Disconnect power before any service or cleaning.
  • Installation: Installation must be performed by qualified personnel. Ensure the unit is placed on a level, stable surface capable of supporting its weight when fully loaded. Maintain adequate ventilation around the cooling unit.
  • Kølemiddel: This appliance contains refrigerant. Servicing should only be performed by certified technicians. Do not damage the refrigerant circuit.
  • Tung genstand: The freezer cell components are heavy. Use appropriate lifting equipment and techniques during assembly to prevent injury.
  • Børn og kæledyr: Keep children and pets away from the appliance, especially during operation and maintenance.

2. Produktet er slutview

The GGM Gastro TKF1818#WKAMF5ND is a high-capacity, modular freezer cell designed for commercial use, offering optimal conditions for the long-term storage of frozen goods. It features robust insulation, a secure door, and an efficient MINUS wall-mounted cooling unit to maintain consistent low temperatures.

GGM Gastro TKF1818#WKAMF5ND Freezer Cell with cooling unit and strip curtain

Figure 2.1: The GGM Gastro TKF1818#WKAMF5ND Freezer Cell, showing the exterior structure, the integrated wall-mounted cooling unit, and an optional strip curtain for enhanced thermal efficiency.

Indre view of the GGM Gastro Freezer Cell with shelving and crates

Figur 2.2: Et interiør view of the freezer cell, illustrating the spacious storage capacity and potential for shelving and organized storage of various food items in crates.

3. Opsætning og installation

3.1 Udpakning og inspektion

  • Carefully unpack all components and check for any shipping damage. Report any damage to the carrier and supplier immediately.
  • Kontroller, at alle dele, der er anført på pakkelisten, er til stede.

3.2 Valg af sted

Vælg en placering, der opfylder følgende kriterier:

  • Level and Stable Surface: The floor must be level and strong enough to support the total weight of the freezer cell and its contents.
  • Ventilation: Ensure adequate air circulation around the cooling unit for efficient heat dissipation. Avoid enclosed spaces.
  • Omgivelsestemperatur: The ambient temperature of the installation area should be within the operating range specified in the technical data.
  • Klarering: Allow sufficient space around the unit for door opening, maintenance, and service access.

3.3 Montering

Assemble the freezer cell panels according to the provided diagrams. Ensure all panels are securely fastened and sealed to prevent thermal leaks.

Dimensional drawing of the freezer cell, top view, showing 1800x1800x2010 dimensions

Figure 3.1: Top-down dimensional drawing of the freezer cell, indicating overall dimensions of 1800mm x 1800mm and the door placement.

Assembly steps for the freezer cell, showing panels being joined and the door installed

Figure 3.2: Visual guide for the assembly process, depicting sequential steps (9, 10, 11, 12) of joining wall panels, installing the door, and integrating the cooling unit.

Install the door ensuring it swings freely and seals tightly when closed. The door handle mechanism should operate smoothly.

Close-up of the freezer cell door handle and floor

Figur 3.3: En detaljeret view of the freezer cell's robust door handle and the durable floor surface, highlighting the quality of construction.

Mount the MINUS wall cooling unit according to its specific instructions, ensuring proper alignment and secure attachment to the freezer cell wall.

Side view of the cooling unit with dimensions

Figure 3.4: Side and top dimensional views of the MINUS wall cooling unit, providing critical measurements for installation and clearance.

3.4 Elektrisk tilslutning

Connect the cooling unit to the electrical supply as per local regulations and the unit's specifications. This must be done by a qualified electrician.

3.5 Første opstart

After assembly and electrical connection, power on the unit. Allow it to run for several hours to reach the desired operating temperature before loading any products.

4. Betjeningsvejledning

4.1 Kontrolpanel

The cooling unit is equipped with a digital control panel to monitor and adjust the internal temperature.

Close-up of the GGM Gastro cooling unit control panel

Figur 4.1: Et nærbillede view of the digital control panel on the MINUS wall cooling unit, displaying temperature readings and control buttons.

  • Temperaturvisning: Shows the current internal temperature of the freezer cell.
  • Indstilling af temperatur: Refer to the cooling unit's specific manual for detailed instructions on how to set the desired temperature. Typically involves pressing a 'Set' button and using arrow keys.
  • Alarmindikatorer: The panel may display error codes or alarm indicators for issues like high temperature, low temperature, or sensor faults.

4.2 Retningslinjer for læsning

  • Do not overload the freezer cell. Ensure proper air circulation around stored items.
  • Distribute weight evenly on shelves (if installed) and the floor.
  • Avoid blocking the air vents of the cooling unit.

4.3 Brug af dør

GGM Gastro Freezer Cell with closed door

Figure 4.2: The GGM Gastro Freezer Cell with its door securely closed, demonstrating its compact and sealed design.

  • Open the door only when necessary and close it promptly to minimize temperature fluctuations and energy consumption.
  • Ensure the door seals properly after each opening.

5. Vedligeholdelse

5.1 Rengøring

  • Indre: Regularly clean the interior surfaces with a mild, food-safe detergent and warm water. Rinse thoroughly and dry completely to prevent ice buildup and odors.
  • Ydre: Tør udvendige overflader af med adamp klæde. Undgå slibende rengøringsmidler.
  • Kondensator spoler: The condenser coils of the cooling unit should be cleaned periodically (e.g., every 3-6 months) to ensure optimal performance. Refer to the cooling unit's manual for specific instructions. This typically involves using a brush or vacuum cleaner to remove dust and debris.

5.2 Optøning

The cooling unit may have an automatic defrost cycle. If manual defrosting is required due to excessive ice buildup, follow these steps:

  • Remove all products from the freezer cell and store them in another cold storage unit.
  • Turn off the cooling unit and open the door.
  • Allow ice to melt naturally. Do not use sharp objects to chip away ice, as this can damage the evaporator coils.
  • Once defrosted, clean and dry the interior before restarting the unit and reloading products.

5.3 Inspektion af dørtætning

Regularly inspect the door gaskets for cracks, tears, or signs of wear. Damaged seals can lead to air leaks, increased energy consumption, and poor temperature performance. Replace worn seals promptly.

6. Fejlfinding

Før du kontakter service,view følgende almindelige problemer og deres mulige løsninger:

ProblemMulig årsagLøsning
Fryseren køler ikkeProblem med strømforsyning
Døren er ikke ordentligt forseglet
Overdreven isdannelse
Beskidte kondensatorspoler
Cooling unit malfunction
Kontroller strømtilslutning og afbryder.
Ensure door is closed tightly and seals are intact.
Afrim enheden.
Rengør kondensatorspolerne.
Kontakt en kvalificeret servicetekniker.
Usædvanlige lydeLøse komponenter
Ventilatorblokering
Problem med kompressoren
Check for loose panels or parts.
Ensure nothing is blocking the fan blades.
Kontakt en kvalificeret servicetekniker.
Overdreven isdannelseHyppige døråbninger
Beskadiget dørtætning
High humidity in ambient air
Minimer døråbninger.
Inspect and replace door seal if necessary.
Sørg for ordentlig ventilation i rummet.
Fejlkode på displaySpecifik systemfejlRefer to the cooling unit's manual for specific error code definitions and troubleshooting steps. If unresolved, contact service.

If the problem persists after attempting these solutions, or if you suspect a major malfunction, contact a qualified service technician or the manufacturer's support team.

7. Specifikationer

AttributVærdi
FabrikantGGM Gastro
ModelnummerTKF1818#WKAMF5ND
Produktmål (L x B x H)180 x 180 x 201 cm
Produktets vægt474 kg
Intern lydstyrkeApprox. 4.30 m3
FarveSølv
Voltage230 volt (DC)

8. Garanti og support

This GGM Gastro product comes with a manufacturer's warranty. Please refer to the warranty card included with your purchase or visit the official GGM Gastro webhjemmeside for detaljerede garantivilkår.

For technical support, spare parts, or service inquiries, please contact GGM Gastro customer service. Have your model number (TKF1818#WKAMF5ND) and purchase date ready when contacting support.

Relaterede dokumenter - TKF1818#WKAMF5ND

Preview GGM Gastro Kølehakker Brugsanvisning
Omfattende brugsanvisning til GGM Gastro kødhakker (model FWKSM350), der dækker levering, garanti, beskrivelse, specifikationer, betjening, termostat, installation, betjening, vedligeholdelse, fejlfinding og ledningsdiagrammer. Vigtig vejledning til sikker og effektiv brug.
Preview GGM Gastro Varmeplade med 2 Varmepladeramps - Brugermanual og specifikationer
Omfattende brugermanual og tekniske specifikationer for GGM Gastro Heat-holdeplade med 2 varmelegemeramps (WPHE2, WPE2). Omfatter installation, drift, sikkerhed, vedligeholdelse, fejlfinding og reservedele.
Preview GGM Gastro DBFP21 bordplade varmluftsovn brugermanual
Brugermanual til GGM Gastro DBFP21 bordpladekonvektionsovn, der dækker vigtige sikkerhedsoplysninger, installation, betjening, vedligeholdelse og fejlfindingsprocedurer.
Preview GGM Gastro Glas- og Aluminiumsrens til Opvaskemaskiner - Professionel Økologisk Rengøringsmiddel
Professionelt miljøvenligt flydende afspændingsmiddel til opvaskemaskiner, designet til glas og aluminium. Dette koncentrerede rengøringsmiddel fra GGM Gastro er sikkert til maskinbrug, forårsager alvorlige forbrændinger på hud og øjne og kræver kun professionel brug. Sikkerhedsdatablad tilgængeligt.
Preview GGM Gastro Varmetallerken med 2 Varmepladeramps Reservedelsliste og eksploderet oversigt View
Detaljeret stykliste og eksploderet liste view Diagram for GGM Gastro varmeplade med 2 varmeelementeramps (Model WPE2). Indeholder produktkoder for hver komponent.
Preview GGM Gastro Espressomaskine Rengøringstabletter - Kraftig Rengøring til Alle Espressomaskiner
GGM Gastro Espressomaskine Rengøringstabletter giver effektiv rengøring af espressomaskiner til hjemmet og industrien. Fjern kafferester, forebyg lugte og vedligehold dit udstyr med disse brugervenlige tabletter. Indeholder sikkerhedsinstruktioner og ingredienser.