This manual provides comprehensive instructions for the installation, operation, and maintenance of the Axis Communications D8208-R Industrial 8-Port Managed PoE++ Switch. This device is designed for robust industrial environments, offering reliable network connectivity and Power over Ethernet (PoE++) capabilities for connected devices. Please read this manual thoroughly before using the product to ensure proper and safe operation.
2. Sikkerhedsoplysninger
Overhold følgende sikkerhedsforanstaltninger for at forhindre skader på produktet og sikre brugerens sikkerhed:
- Strømkilde: Use only the specified power supply for this device. Ensure the power source meets the voltage og nuværende krav.
- Miljø: Install the switch in an environment that complies with its operating temperature and humidity specifications. Avoid exposure to direct sunlight, excessive heat, moisture, or corrosive substances.
- Ventilation: Sørg for tilstrækkelig ventilation omkring enheden for at forhindre overophedning. Bloker ikke ventilationsåbningerne.
- Installation: Installationen skal udføres af kvalificeret personale i overensstemmelse med lokale el-forskrifter og -regler.
- Opretholdelse: Do not attempt to open or service the device yourself. Refer all servicing to qualified service personnel.
- Kabler: Use appropriate and certified cables for all connections.
3. Pakkens indhold
Verify that all items are present in the package. If any item is missing or damaged, contact your supplier.
- AXIS D8208-R Industrial 8-Port Managed PoE++ Switch
- Hurtig installationsvejledning
- Mounting Kit (e.g., DIN rail clip, screws)
- Terminal Block Connectors (for power input)
4. Produktet er slutview
The AXIS D8208-R is a robust industrial switch designed for demanding applications. It features multiple Ethernet ports with Power over Ethernet capabilities and advanced management features.
4.1 Frontpanelets layout

Figur 1: Front view of the AXIS D8208-R Industrial Switch. This image displays the front panel of the switch, highlighting the various Ethernet ports, power input terminals, LED indicators, and the console port. Ports 1-4 are 1G PoE++ ports, ports 5-8 include 1G and 2.5G PoE++ capabilities, and ports 9-10 are 10G SFP+ ports.

Figur 2: Detaljeret front view of the AXIS D8208-R Industrial Switch. This image provides a closer look at the port configuration and LED indicators. It shows the two 10G SFP+ uplink ports (9 and 10) at the bottom, the console port, and the reset button. The power input terminals are visible on the right side.
4.2 Components Description
- Ethernet-porte (1-4): 1 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- Ethernet-porte (5-8): 1 Gigabit and 2.5 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- 10G Ports (9-10): 10 Gigabit SFP+ uplink ports for high-speed connections.
- Power Input (P1, P2): Redundant power input terminals for enhanced reliability.
- Konsolport: RJ45 port for local management and configuration via a serial connection.
- Nulstil knap: Used to reset the device to factory defaults or reboot.
- LED-indikatorer:
- SYS: Systemstatusindikator.
- P1, P2: Power input status indicators.
- ALM: Alarmindikator.
- RM, RC: Redundancy Management / Redundancy Control indicators.
5. Opsætning
5.1 Montering
The AXIS D8208-R is designed for DIN rail mounting.
- Attach the DIN rail clip (if not pre-installed) to the rear of the switch using the provided screws.
- Hook the top edge of the DIN rail clip onto the DIN rail.
- Push the bottom of the switch firmly towards the DIN rail until it clicks into place.
- Sørg for, at kontakten er sikkert fastgjort til DIN-skinnen.
5.2 Strømtilslutning
The switch supports redundant power inputs (P1 and P2) for increased reliability.
- Ensure the power source is turned off before making any connections.
- Connect the positive (+) and negative (-) wires from your DC power supply to the corresponding terminals on the provided terminal block connector for P1.
- Insert the terminal block connector into the P1 power input port on the switch.
- (Optional) For redundant power, repeat steps 2 and 3 for the P2 power input.
- Once all connections are secure, turn on the power supply. The P1 and/or P2 LEDs should illuminate.
5.3 Netværksforbindelse
Connect network devices and uplink connections.
- Standard Devices: Connect your network devices (e.g., IP cameras, access points) to ports 1-8 using standard Ethernet cables. These ports will provide PoE++ power if the connected device supports it.
- Uplink: For high-speed uplink to your core network, insert compatible SFP+ transceivers into ports 9 and 10, then connect fiber optic cables.
5.4 Indledende konfiguration
The switch can be configured via a web-based interface or a command-line interface (CLI) through the console port.
- Web Interface: Connect a computer to any Ethernet port on the switch. The switch will typically obtain an IP address via DHCP or use a default static IP. Refer to the Quick Installation Guide for the default IP address and login credentials.
- Konsolport: Connect a serial cable from your computer to the console port on the switch. Use a terminal emulation program (e.g., PuTTY) with the specified serial settings (e.g., 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control) to access the CLI.
6. Betjening
6.1 LED-indikatorer
Monitor the LED indicators for the operational status of the switch.
| LED | Status | Beskrivelse |
|---|---|---|
| SYS | Grøn (fast) | Systemet fungerer normalt. |
| SYS | Grøn (blinker) | System is booting or performing an operation. |
| P1 / P2 | Grøn (fast) | Corresponding power input is active. |
| ALM | Red (Solid/Flashing) | An alarm condition exists (e.g., power failure, port error). Check system logs. |
| Port-lysdioder | Grøn (fast) | Link etableret. |
| Port-lysdioder | Grøn (blinker) | Data activity. |
6.2 Administration og konfiguration
The AXIS D8208-R is a managed switch, offering a range of configuration options for network optimization and security.
- Web-baseret GUI: Få adgang til kontaktens web interface via a standard web browser to configure VLANs, QoS, port settings, PoE management, security features, and more.
- CLI: For advanced users, the Command Line Interface provides granular control over all switch functions.
- SNMP: The switch supports SNMP for integration with network management systems.
7. Vedligeholdelse
7.1 Rengøring
To maintain optimal performance, periodically clean the exterior of the switch.
- Sørg for, at strømmen er afbrudt før rengøring.
- Brug en blød, tør klud til at tørre de udvendige overflader af.
- Brug ikke flydende rengøringsmidler eller aerosolrengøringsmidler, da de kan beskadige enheden.
- Hold ventilationsåbningerne fri for støv og snavs.
7.2 firmwareopdateringer
Tjek regelmæssigt Axis Communications website for the latest firmware updates. Firmware updates can provide new features, performance improvements, and security enhancements.
- Download den relevante firmware file from the official Axis Communications support page for your model.
- Follow the instructions provided with the firmware update package for the correct update procedure, typically performed via the web interface.
8. Fejlfinding
If you encounter issues with your AXIS D8208-R switch, refer to the following common troubleshooting steps.
- Ingen strøm:
- Check power cable connections to the switch and the power source.
- Verify the power supply is functioning correctly and providing the correct voltage.
- Ensure the P1/P2 LEDs are illuminated.
- Ingen netværksforbindelse:
- Check Ethernet cable connections for both the switch and the connected device.
- Verify the link/activity LEDs on the respective port are active.
- Ensure the connected device is powered on and configured correctly.
- Check switch configuration (VLANs, port status) via the web interface eller CLI.
- PoE-enhed tænder ikke:
- Ensure the connected device is PoE compatible and within the switch's PoE budget.
- Check the PoE status for the port in the switch's management interface.
- Verify the Ethernet cable is a standard Cat5e/6 or higher.
- Adgang Web Interface Fails:
- Confirm your computer's IP address is in the same subnet as the switch, or that DHCP is functioning.
- Try accessing the switch via the console port to verify its IP configuration.
- Ryd din browsers cache, eller prøv en anden browser.
- Gendan fabriksindstillinger: If issues persist and you need to restore default settings, press and hold the reset button for approximately 10-15 seconds until the SYS LED changes behavior, then release. Advarsel: Dette vil slette alle brugerdefinerede konfigurationer.
9. Specifikationer
| Feature | Detalje |
|---|---|
| Mærke | Axis Communications |
| Modelnummer | 02621-001 |
| Produktnavn | AXIS D8208-R Industrial 8-Port Managed PoE++ Switch |
| Havne | 8 x PoE++ Ethernet (1G/2.5G), 2 x 10G SFP+ |
| Strømindgang | Redundant DC power input (terminal blocks) |
| Varens vægt | 3.37 pund (ca. 1.53 kg) |
| Pakkedimensioner | 1.97 x 0.79 x 0.79 tommer (ca. 5 x 2 x 2 cm) |
| Fabrikant | AXIS - ACCESS CONTROL |
| Dato først tilgængelig | 29. maj 2024 |
10. Garanti og support
For detailed warranty information, technical support, and additional resources, please visit the official Axis Communications webwebsted.
Webwebsted: www.axis.com
Contact Axis Communications support for assistance with product installation, configuration, or troubleshooting beyond the scope of this manual.