1. Introduktion
This manual provides comprehensive instructions for the AIDA Wireless Caregiver Pager System, Model BTSWD-SOS-201. This system is designed to provide reliable communication between a caregiver and an individual requiring assistance, such as the elderly, patients, or children. Please read this manual thoroughly before operating the device to ensure proper function and safety.

Image 1.1: AIDA Wireless Caregiver Pager System, including the plug-in receiver and two portable SOS call buttons.
2. Produktkomponenter
The AIDA Wireless Caregiver Pager System includes the following items:
- 1 x stikkontaktmodtager
- 2 x SOS Call Buttons (Transmitters)
- 2 x Lanyards for Call Buttons
- 1 x Mini-skruetrækker (til batteriudskiftning)
- 1 x Brugermanual (dette dokument)
3. Specifikationer
Se tabellen nedenfor for detaljerede produktspecifikationer:
| Feature | Specifikation |
|---|---|
| Produktbeskrivelse | Caregiver Personsøger |
| Sender størrelse | 3.18" x 1.3" x 0.46" (81 x 33 x 11.7 mm) |
| Modtager størrelse | 3.18" x 2.36" x 1.3" (81 x 60 x 33 mm) |
| Lanyard Length | 17.7in / 45cm (whole lanyard) |
| Working Voltage of Plug-in Receiver | AC 110-240V |
| Antal klokkespil | 58 |
| Volumenområde | 0-110 dB, 5 niveauer |
| Kan udvides | Ja |
| Arbejdsfrekvens | 433.92 MHz |
| Driftstemperatur | -10°C til +55°C (14°F til 131°F) |
| Sender batteri | CR2016 Lithium battery * 2 |
| Vandtæt vurdering | IP55 (Call Buttons) |
| Maksimal rækkevidde | 600 fod (åbent område) |

Image 3.1: Visual representation of product specifications.
4. Opsætningsvejledning
4.1. Receiver Placement
Plug the receiver into a standard electrical outlet in a central location where the sound can be easily heard by the caregiver. Ensure it is within the 600-foot operating range of the call buttons.
4.2. Selecting a Ringtone
Before pairing, you can select your preferred ringtone for the receiver:
- Plug the receiver into an electrical socket.
- Press the Forward Button (Z) or Backward Button (Z with arrow pointing left) on the side of the receiver to cycle through the 58 available ringtones.
- Stop on your desired ringtone.

Image 4.1: Receiver with musical notes illustrating the 58 chime options.
4.3. Justering af lydstyrke
The receiver has 5 adjustable volume levels (0 dB to 110 dB):
- Locate the Volume Control button on the side of the receiver.
- Press the Volume Control button repeatedly to cycle through the 5 volume levels until your desired loudness is reached.

Image 4.2: Visual representation of the 5 volume levels.
4.4. Parring af opkaldsknapper med modtager
Follow these steps to pair the call buttons with the receiver:
- Trin 1: Plug the receiver into an electrical socket. Select your favorite ringtone before pairing using the Forward or Backward buttons.
- Trin 2: Press and hold the Volume Control button on the receiver for approximately 5 seconds until a "Ding-dong" sound is heard and the LED indicator starts flashing. This indicates the receiver is in pairing mode.
- Trin 3: While the receiver's LED is flashing, press the SOS call button (transmitter) once. The receiver will play the selected ringtone automatically, confirming successful pairing.
Repeat these steps for any additional call buttons you wish to pair. Each button can be assigned a different chime if desired by selecting a new chime before pairing each button.

Image 4.3: Pairing process for the AIDA Caregiver Pager.
5. Betjeningsvejledning
The AIDA Wireless Caregiver Pager System is simple to operate:
- Sådan bærer du opkaldsknappen: The SOS call button can be worn around the neck using the included lanyard, or placed in an easily accessible location such as a bedside table, bathroom, or wheelchair.
- Indledning af et opkald: When assistance is needed, simply press the red SOS button on the call transmitter.
- Receiving the Alert: Upon pressing the SOS button, the receiver will sound the selected chime and its LED indicator will flash, alerting the caregiver.

Image 5.1: A person activating the SOS button during an emergency.

Image 5.2: The receiver alerting a caregiver in another room.
5.1. Driftsområde
The system offers an ultra-long range of up to 600 feet in an open area. This ensures reliable signal transmission throughout most homes and yards, allowing caregivers freedom of movement while remaining reachable.

Image 5.3: Illustration of the 600-foot operating range.
6. Vedligeholdelse
6.1. Call Button Battery Replacement
The SOS call buttons are powered by two CR2016 Lithium batteries. When the button's indicator light no longer flashes or the range decreases significantly, it's time to replace the batteries.
- Trin 1: Use the included mini screwdriver to unscrew the two small screws on the back cover plate of the call button. Carefully remove the back cover.
- Trin 2: Gently push the old batteries out and replace them with two new CR2016 Lithium batteries, ensuring correct polarity (+/-).
- Trin 3: Place the back cover panel back onto the call button and tighten the screws securely.

Image 6.1: Battery replacement steps for the SOS call button.
6.2. Rensning
Wipe the receiver and call buttons with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the devices are dry before use.
6.3. Waterproof and Dustproof (Call Buttons)
The call buttons are rated IP55 waterproof and dustproof, meaning they are protected against dust ingress and low-pressure water jets from any direction. This makes them suitable for use in bathrooms or outdoors in light rain. However, they are not designed for submersion in water.

Image 6.2: IP55 waterproof and dustproof features of the call button.
7. Fejlfinding
- Ingen alarm fra modtager:
- Sørg for, at modtageren er korrekt tilsluttet en fungerende stikkontakt.
- Check if the call button batteries need replacement (refer to Section 6.1).
- Verify that the call button is paired with the receiver (refer to Section 4.4).
- Ensure the call button is within the 600-foot operating range of the receiver. Obstacles like thick walls or metal structures can reduce range.
- Receiver Volume Too Low/High:
- Juster lydstyrken ved hjælp af lydstyrkeknappen på modtageren (se afsnit 4.3).
- Unwanted Chime Sound:
- Change the ringtone using the Forward or Backward buttons on the receiver (refer to Section 4.2).
- Opkaldsknappen svarer ikke:
- Replace the batteries in the call button (refer to Section 6.1).
- Re-pair the call button with the receiver (refer to Section 4.4).
8. Sikkerhedsoplysninger
- Forsøg ikke selv at skille enhederne ad eller reparere dem. Kontakt kundesupport for at få hjælp.
- Keep the devices away from extreme temperatures, direct sunlight, and open flames.
- Bortskaf gamle batterier i henhold til lokale regler.
- This device is an aid and should not replace direct supervision or professional medical care.
9. Garanti og support
The AIDA Wireless Caregiver Pager System comes with a 1-year warranty. Additionally, it is backed by a 30-day free return policy and free lifetime technical online support available within 24 hours.
For any questions, technical assistance, or warranty claims, please contact the seller or AIDA customer support directly. Refer to your purchase documentation for specific contact details.