Produkt overview
The Blueridge DIY Quick Connect Mini Split system is designed for efficient heating and cooling without the need for professional HVAC installation. This system features a pre-charged R410 quick-connect line set, allowing for a straightforward installation process using common tools. It is suitable for various applications, including bonus rooms, garages, home offices, and sheds, providing year-round comfort with its inverter heat pump technology.

Figure 1: Complete Blueridge DIY Mini Split System including the indoor air handler, outdoor condenser, pre-charged line set, and various installation components like remotes and sealing materials.
Sikkerhedsoplysninger
Read all instructions carefully before installation and operation. Failure to follow safety guidelines may result in property damage, personal injury, or death. Keep this manual for future reference.
- Ensure the power supply is disconnected before performing any installation or maintenance.
- Brug kun den angivne voltage (220V) for this unit.
- Do not attempt to modify the system or its components.
- Sørg for korrekt ventilation omkring udendørsenheden.
- Keep children and pets away from the units during operation and maintenance.
Komponenter inkluderet
The Blueridge DIY Mini Split system includes the following main components:
- 36,000 BTU Single Zone Do It Yourself Wall Mounted Ductless Indoor Air Handler
- 36,000 BTU 18 SEER Single Zone 220V Do It Yourself Ductless Mini Split Outdoor Condenser
- Installation Kit (includes pre-charged line set, remote controls, and other necessary accessories)

Figur 2: Detaljeret view of the Premium Installation Kit, which includes insulation, rubber mounting feet, mounting screws, wall sleeve kit, electrical whip, disconnect box, neoprene, repair tape, thread sealant, WiFi connection, pre-flared and charged copper line set, and remote controls.
Opsætning og installation
The Blueridge DIY Mini Split system is designed for easy installation without specialized HVAC tools or training. The key to its simplicity is the pre-charged R410 quick-connect line set, eliminating the need for vacuum pumps or refrigerant charging.
Installationstrin:
- Monter indendørsenheden: Select an appropriate location on an interior wall, ensuring sufficient clearance for airflow and maintenance. Secure the mounting plate and then the indoor air handler.
- Monter udendørsenheden: Choose a stable, level location outdoors, ensuring adequate space for air circulation and drainage. The outdoor condenser is designed for durability.

Figure 3: The 36,000 BTU outdoor condenser unit, engineered for easy installation without soldering or a vacuum pump, and designed for quiet operation.
- Connect the Line Set: Carefully uncoil the pre-charged quick-connect line set. Connect one end to the indoor unit and the other to the outdoor unit. Ensure the connections are tight and secure. No special tools are required for these connections.
- Open the Valves: Once the line set is securely connected, open the valves on the outdoor unit. The pre-charged refrigerant will automatically release into the system.
- Elektriske forbindelser: Connect the system to a dedicated 220V power supply as per local electrical codes. An electrical whip and disconnect box are included in the installation kit.
For detailed dimensions and clearances, refer to the size reference guide.

Figure 4: Size reference guide providing dimensions for both the indoor air handler (approximately 14"H x 49.5"W x 11"D) and the outdoor condenser (approximately 32"H x 37"W x 16"D).
Betjeningsvejledning
Your Blueridge Mini Split system offers various operating modes and convenient control options.
Kontrolmuligheder:
- Fjernbetjening: Use the included wireless remote control to adjust temperature, mode, fan speed, and other settings.
- WiFi-app-kontrol: Connect your system to your home WiFi network to control it remotely using the dedicated Blueridge app on your Apple or Android smart device. This allows for control from anywhere with an internet connection.
Driftstilstande:
- Køletilstand: Provides efficient cooling, ideal for warmer climates or seasons.
- Opvarmningstilstand: Utilizes inverter heat pump technology to provide effective heating, even in low ambient temperatures down to -13 degrees Fahrenheit. This makes the system suitable for year-round climate control.
- Sove mode: This mode adjusts temperature settings automatically during sleep hours to optimize comfort and energy savings.
- Automatisk genstart: I tilfælde af en magt outage, the unit will automatically resume its previous operating settings once power is restored.

Figure 5: The indoor wall-mount air handler, featuring easy installation, high efficiency, Wi-Fi capability, and quiet operation.

Figure 6: The Blueridge indoor and outdoor units, emphasizing the SEER 18 rating for higher energy efficiency, contributing to lower electrical bills.
Opretholdelse
Regular maintenance ensures optimal performance and longevity of your Blueridge Mini Split system.
- Rengøring af luftfilter: Clean the indoor unit's air filters regularly (e.g., monthly or bi-monthly, depending on usage and air quality). Refer to the specific instructions in your detailed user manual for filter removal and cleaning.
- Rengøring af udendørsenhed: Keep the outdoor condenser coil free of debris, leaves, and dirt. The Gold Fin Condenser is designed to resist long-term corrosion, especially beneficial in coastal environments.
- Afløbskontrol: Periodically check the condensate drain line for blockages to ensure proper water drainage from the indoor unit.
Fejlfinding
Dette afsnit indeholder løsninger på almindelige problemer, du kan støde på. Kontakt kundesupport ved mere komplekse problemer.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke | Ingen strøm, afbryder udløst, fjernbetjeningens batteri lavt. | Kontroller strømforsyningen, nulstil afbryderen, udskift fjernbetjeningens batterier. |
| Utilstrækkelig køling/opvarmning | Dirty air filters, blocked outdoor unit, incorrect mode setting. | Clean air filters, clear debris from outdoor unit, verify mode. |
| Usædvanlig støj | Loose parts, debris in fan, unit not level. | Inspect for loose components, remove debris, ensure unit is level. |
| Vandlækage fra indendørsenhed | Blocked condensate drain line. | Clear the condensate drain line. |
Specifikationer
| Attribut | Værdi |
|---|---|
| Mærke | Blueridge |
| Modelnummer | 453097400 |
| Kapacitet | 3 tons (36,000 BTU) |
| Sæsonbestemt energieffektivitetsforhold (SEER) | 18 |
| Voltage | 220 volt |
| Støjniveau | 34 dB |
| Kølemiddel | R 410A (Pre-charged) |
| Varens vægt | 303 pund |
| Produktmål (udendørsenhed) | 16" D x 37" B x 32" H |
| Særlige funktioner | Remote Controlled, Inverter Compressor, WiFi Enabled, Heating And Cooling Function, Low Ambient Heating/Cooling (-13°F) |
| Materiale Type | Metal (Gold Fin Condenser) |
Garanti og support
Blueridge is committed to providing reliable support for your DIY Mini Split system.
- Livsvarig teknisk support: U.S.-based experts are available to assist you with any technical questions or issues throughout the lifespan of your product.
- Replacement Part Availability: A wide range of replacement parts are available to ensure the long-term serviceability of your unit.
For assistance, please refer to the contact information provided with your product documentation or visit the official Blueridge support webwebsted.