LINGXIAO 48WUA1001C-II

Produktbrugsanvisning

LINGXIAO SPA Pump - Model: 48WUA1001C-II

1. Produktet er slutview

The LINGXIAO 48WUA1001C-II SPA Pump is a high-performance, two-speed motor designed for hot tubs and spas. It offers reliable operation and is engineered for compatibility with various OEM models, providing an efficient replacement solution.

1.1. Nøglefunktioner

  • Modelkompatibilitet: Designed to be identical to original SPA factory pumps for perfect compatibility.
  • Two-Speed Operation: Features a low speed (0.35HP, 3.8A) for continuous filtration and a high speed (1.5HP, 10.3A) for powerful jet action.
  • Holdbar motor: Equipped with a pure copper winding motor, 80,000 capacitor charge-discharge cycle tested, and a thermal protector from Texas Instruments for long service life.
  • Stille drift: Incorporates Anti-Creep Bearings for reduced noise during operation.
  • Certificeringer: UL, CUL, ETL certified for safety and quality.
  • Easy Plumbing: Connects to 2-inch plumbing and includes a free set of 2-inch unions for quick installation.

1.2. Produktkomponenter

The LINGXIAO SPA Pump consists of the main pump body, the motor housing, and connection unions. The pump is designed for easy integration into existing spa systems.

LINGXIAO 2 Speed Hot Tub SPA Pump with two white unions

Figure 1: LINGXIAO 2 Speed Hot Tub SPA Pump (Model: 48WUA1001C-II) with included unions.

2. Opsætning og installation

2.1. Sikkerhedsforanstaltninger

  • Always turn off the power to the hot tub at the circuit breaker before beginning any installation or maintenance.
  • Ensure the hot tub is drained before disconnecting the old pump.
  • Kontakt en kvalificeret elektriker, hvis du er usikker på den elektriske ledningsføring.
  • Brug passende personlige værnemidler (PPE) under installationen.

2.2. Kontrol før installation

Before installing, verify that the new pump's specifications match your existing system. This model operates at 115V/60Hz. Confirm that your hot tub's plumbing and electrical connections are compatible.

2.3. Adjusting Discharge Location

The pump's discharge can be adjusted to one of three locations (12 o'clock, 3 o'clock, 9 o'clock) to fit your plumbing configuration. The factory default is 12 o'clock. To adjust, loosen the four indicated screws on the pump housing, rotate the wet end to the desired position, and then securely tighten the screws.

Diagram showing how to adjust the pump's discharge location by loosening screws and rotating the wet end.

Figure 2: Adjusting the pump's discharge location.

Video 1: Visual guide on adjusting the pump's discharge location and general features.

2.4. VVS-tilslutning

Connect the pump to your hot tub's 2-inch plumbing using the provided unions. Ensure all connections are tight and leak-free. It is recommended to use plumbing sealant for a secure fit.

Diagram showing the pump connected to 2-inch plumbing with water flow indicated.

Figure 3: Plumbing connection with 2-inch unions.

2.5. Elektriske ledninger

This pump is a two-speed model designed for 115V/60Hz circuits. Proper wiring is critical for safe and correct operation. Refer to the diagram below and the instructional video for detailed wiring steps.

  • Turn off power first.
  • Ensure the corresponding voltage of the circuit (115V/60Hz).
  • Tilslut Red wire (High speed) til terminal H.
  • Tilslut White wire (Neutral wire) til terminal C.
  • Tilslut Black wire (Low speed) til terminal L.
  • Tilslut Green wire (Ground wire) til terminalen Jord.
Detailed wiring diagram for the 115V two-speed SPA pump, showing connections for high speed, low speed, neutral, and ground.

Figure 4: 115V Two-Speed Wiring Diagram.

Video 2: Comprehensive guide on wiring the LINGXIAO 48WUA series SPA pump for two-speed operation.

3. Betjening

3.1. Indledende opstart

After successful installation and wiring, fill your hot tub with water. Ensure all valves are open and there are no airlocks in the system. Turn on the power to the hot tub. The pump should prime itself and begin circulating water.

3.2. Two-Speed Functionality

This pump offers two operational speeds:

  • Lav hastighed: Ideal for continuous filtration and heating, drawing approximately 3.8 Amps and providing 0.35 HP.
  • Høj hastighed: Provides maximum power for jets and hydrotherapy, drawing approximately 10.3 Amps and delivering 1.5 HP.

Switch between speeds using your hot tub's control panel.

3.3. Strømningshastighed

The pump is capable of delivering a maximum flow rate of 122 Gallons Per Minute (GPM) at high speed and a minimum flow rate of 53 GPM at low speed, ensuring efficient water circulation and powerful jet performance.

Diagram illustrating the flow rates of the SPA pump at low and high speeds, showing 53 GPM minimum and 122 GPM maximum.

Figure 5: Pump Flow Rates.

4. Vedligeholdelse

4.1. Regelmæssig kontrol

  • Periodically inspect the pump for any signs of leaks around the unions or pump seals.
  • Listen for unusual noises during operation, which could indicate a bearing issue or debris in the wet end.
  • Ensure the motor's cooling fan is free from obstructions to prevent overheating.

4.2. Rensning

Keep the exterior of the pump clean and free of dust and debris. Do not spray water directly onto the motor or electrical components.

4.3. Vinterklargøring

In climates where temperatures drop below freezing, it is essential to properly winterize your hot tub and pump to prevent freeze damage. This typically involves draining the pump and plumbing lines completely.

5. Fejlfinding

This section provides solutions to common issues you might encounter with your SPA pump.

5.1. Almindelige problemer

  • Pumpen starter ikke:
    • Kontroller, om afbryderen er udløst.
    • Verify all electrical connections are secure and correctly wired (refer to Section 2.5).
    • Ensure the hot tub's control panel is sending power to the pump.
  • Low Pressure or No Water Flow:
    • Check for airlocks in the plumbing system; try bleeding air from the pump or jets.
    • Inspect the hot tub filter for clogs and clean or replace if necessary.
    • Ensure all valves in the plumbing system are fully open.
    • Check for debris or obstructions in the pump's wet end or impeller.
  • Overdreven støj:
    • A loud grinding or squealing noise may indicate worn bearings.
    • Vibration can be caused by loose mounting bolts; ensure the pump is securely fastened.
    • Air cavitation (sucking air) can cause noise; check water level and ensure no air leaks in the suction line.

5.2. Kontakt support

If you encounter issues that cannot be resolved using the troubleshooting steps above, please contact LINGXIAO PUMP Support through Amazon 'Ask a question'. Our technical support team is available to assist you within 24 hours.

6. Tekniske specifikationer

SpecifikationDetalje
MærkeLINGXIAO
Model48WUA1001C-II
Voltage115 volt (AC)
Power (High Speed)1.5 HK
Power (Low Speed)0.35 HK
Amperage (High Speed)10.3A
Amperage (Low Speed)3.8A
Maksimal flowhastighed122 gallon pr. Minut
Minimum flowhastighed53 gallon pr. Minut
Produktdimensioner8 cm L x 13 cm B x 8 cm H
Varens vægt26 pund
MaterialeCoiling iron
FabrikantLX

7. Garanti og support

7.1. Garantioplysninger

The LINGXIAO 48WUA1001C-II SPA Pump comes with a 1-års garanti fra købsdatoen. Denne garanti dækker fabrikationsfejl og sikrer, at produktet opfylder de specificerede ydeevnestandarder under normal brug.

7.2. Kundesupport

For any questions, technical assistance, or warranty claims, please do not hesitate to contact LINGXIAO PUMP Support. You can reach us through the 'Ask a question' feature on Amazon. We are committed to providing prompt and helpful support within 24 hours to resolve any issues you may encounter.

Relaterede dokumenter - 48WUA1001C-II

Preview LINGXIAO Variable Speed ​​Pumps Instruktionsmanual - Relaax-serien
Omfattende instruktionsmanual til LINGXIAO Relaax-serien af ​​poolpumper med variabel hastighed (Relaax130-VS, Relaax220-VS, Relaax390-VS), der dækker installation, drift, vedligeholdelse, sikkerhed, fejlfinding og tekniske specifikationer.
Preview Hot Spring Limelight Collection Lynstartguide: Opsætning, vedligeholdelse og sikkerhed
En omfattende hurtigstartguide til Hot Spring Limelight Collection-spaer, der dækker indledende opsætning, vandpleje, vigtige vedligeholdelsestips, vigtige sikkerhedsinstruktioner og elektriske krav til sikker drift.
Preview VEVOR SPA-PUMPE 48WUA1501C-II/48WUA2002C-II Installations- og betjeningsmanual
Omfattende installations-, betjenings-, sikkerheds- og fejlfindingsvejledning til VEVOR SPA PUMP-modellerne 48WUA1501C-II og 48WUA2002C-II. Lær, hvordan du korrekt installerer, tilslutter og vedligeholder din spapumpe for optimal ydeevne.
Preview VEVOR Spa Pumps Instruction Manual - Models 48HT1501-II, 56HT300-II, 56HT400-II
Comprehensive instruction manual for VEVOR Spa Pumps (Models 48HT1501-II, 56HT300-II, 56HT400-II), covering installation, safety, operation, maintenance, and troubleshooting. Learn how to properly install and use your VEVOR spa pump for optimal performance.
Preview Bullfrog Spas brugermanual: Installation, drift og vedligeholdelse
Omfattende brugermanual til Bullfrog Spas serie I, serie II og SportX-serie spabade. Dækker installation, betjening, sikkerhed, vedligeholdelse og fejlfinding af din Bullfrog Spa.
Preview 2003 Dimension One Spas brugermanual - Sikkerheds-, betjenings- og vedligeholdelsesvejledning
This comprehensive owner's manual for the 2003 Dimension One Spas hot tub models provides essential safety instructions, detailed operation guides, routine maintenance procedures, and troubleshooting tips. Learn about features like the Jet System Selector Valve, Water Management Systems (UltraPure, CrystalZone), and Dynamic Massage Sequencer. Ensure safe and optimal use of your spa with this indispensable guide.