Indledning
Thank you for choosing the Lefton Temperature Display Shower Set, Model SST2203-2. This manual provides detailed instructions for the safe and efficient installation, operation, and maintenance of your new shower system. Please read this manual thoroughly before installation and retain it for future reference.
Produkt overview
The Lefton SST2203-2 is a modern shower system designed for enhanced comfort and functionality. It features a temperature display, dual shower heads (rainfall and handheld), a waterfall faucet, and an integrated spray gun, all controlled by a 4-in-1 system.
Nøglefunktioner:
- Integrated Temperature Display for precise water temperature monitoring.
- Dual Shower Heads: Large rainfall shower head and a versatile handheld shower.
- Waterfall Faucet for a unique bathing experience.
- Convenient Spray Gun for targeted cleaning.
- 4-in-1 Control System for easy switching between water outlet modes.
- Adjustable Hot & Cold Water mixing.
- Durable Brass construction with a polished finish.
Komponenter inkluderet:
- Lefton Shower System SST2203 (Main Unit)
- Regnbrusehoved
- Håndbruserhoved med slange
- Sprøjtepistol
- Monteringshardware
- Brugermanual

Specifikationer
| Attribut | Detalje |
|---|---|
| Mærke | Lefton |
| Modelnummer | SST2203 |
| Farve | Grå |
| Materiale | Brass, Silicone |
| Finish Type | Poleret |
| Antal håndtag | 1 |
| Monteringstype | Vægmontering |
| Produktdimensioner | 1 x 1 x 33.5 tommer |
| Varens vægt | 15.87 pund |
| Installationsmetode | Vægmonteret |
| Batterier påkrævet? | Ingen |
Opsætning og installation
Professional installation is recommended for this shower system. Ensure all local plumbing codes are followed. Turn off the main water supply before beginning installation.
Kontrol før installation:
- Kontroller, at alle komponenter er til stede og ubeskadigede.
- Ensure adequate water pressure is available.
- Confirm wall structure can support the weight of the shower system.
Installationstrin:
- Mål og markér: Use the provided template or measure carefully to mark drilling points on the wall for the main shower column and control unit. Refer to the dimension diagram for recommended heights.
- Bore huller: Bor huller på de markerede steder, og isæt vægankre om nødvendigt.
- Monter styreenhed: Secure the main control unit to the wall using the provided screws. Ensure it is level.
- Tilslut vandledninger: Connect the hot and cold water supply lines to the corresponding inlets on the control unit. Use appropriate sealants and ensure connections are tight to prevent leaks.
- Installer brusesøjle: Attach the vertical shower column to the control unit and secure it to the upper wall bracket.
- Attach Shower Heads: Connect the rainfall shower head to the top of the column and the handheld shower head hose to its designated outlet on the control unit.
- Install Spray Gun: Connect the spray gun hose to its outlet.
- Test system: Turn on the main water supply and check for any leaks. Test all functions (rainfall, handheld, waterfall, spray gun, temperature display).


Betjeningsvejledning
The Lefton SST2203-2 shower system offers intuitive controls for a personalized showering experience.
Temperaturkontrol:
- The main handle on the control unit adjusts the water temperature. Rotate it to achieve the desired hot or cold mix.
- The digital display will show the current water temperature in real-time.
- For safety, a temperature lock feature may be present to prevent accidental scalding. Refer to the specific markings on your unit for adjustment.

Water Outlet Mode Selection:
The control panel features distinct buttons for selecting different water outlet modes:
- Regnbyge: Press the button with the rainfall icon to activate the overhead shower.
- Håndbruser: Press the button with the handheld shower icon to use the flexible handheld shower.
- Vandfaldshane: Press the button with the waterfall icon to engage the integrated waterfall spout.
- Sprøjtepistol: Press the button with the spray gun icon to activate the high-pressure spray gun.




Opretholdelse
Regular cleaning and maintenance will ensure the longevity and optimal performance of your Lefton shower system.
Rensning:
- Use a soft cloth and mild soap or a non-abrasive bathroom cleaner to wipe down all surfaces.
- Undgå slibende rengøringsmidler, skuresvampe eller barske kemikalier, da disse kan beskadige overfladen.
- Rinse thoroughly with water and dry with a soft cloth to prevent water spots.
Descaling Shower Nozzles:
Over time, mineral deposits (limescale) can build up in the shower head nozzles, affecting water flow. Many Lefton shower heads feature flexible silicone nozzles for easy cleaning.
- Gently rub the silicone nozzles on the rainfall and handheld shower heads to dislodge any mineral buildup.
- For stubborn deposits, a solution of white vinegar and water can be used. Soak the shower head (if detachable) or apply the solution with a cloth, then rinse thoroughly.

Fejlfinding
If you encounter issues with your shower system, refer to the following common problems and solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Ingen vandgennemstrømning eller lavt tryk | Main water supply off, clogged nozzles, kinked hose, low household water pressure. | Check main water supply. Clean shower head nozzles (see Maintenance). Inspect hoses for kinks. Consult a plumber for household water pressure issues. |
| Water temperature is incorrect or inconsistent | Incorrect temperature setting, issues with hot/cold water supply, faulty thermostatic cartridge. | Adjust temperature handle. Check hot and cold water supply valves. If problem persists, contact customer support; a professional may need to inspect the cartridge. |
| Lækager fra forbindelser | Loose connections, damaged seals/washers. | Turn off water supply. Tighten connections carefully. Replace any damaged washers or seals. |
| Digital temperature display not working | No power (if battery-operated, though this model is not), sensor issue. | Ensure water flow is active. If the display remains off, contact customer support. |
| Difficulty switching between modes | Debris in diverter mechanism, worn diverter. | Flush the system by running water through all outlets. If buttons are stiff or unresponsive, contact customer support. |
Garanti og support
Lefton products are manufactured to high-quality standards. For specific warranty details, please refer to the warranty card included with your purchase or visit the official Lefton webwebsted.
Kundesupport:
Should you have any questions, require technical assistance, or need to report an issue, please contact Lefton customer service:
- E-mail: kunde@leftonhome.com (24/7 Service)
- Ring til: 1 (601) 564 0548 (English Only, Monday - Friday: 9:00 AM - 6:00 PM PST)

For more information about Lefton products, visit our official brand store: Lefton Brand Store