1. Introduktion og overview
The Fluke 87V Max True-RMS Digital Multimeter is a robust and reliable instrument designed for professional electrical troubleshooting. Its durable construction, including an IP67 waterproof and dustproof rating, makes it suitable for demanding industrial and outdoor environments, particularly in solar energy applications. This manual provides essential information for the safe and effective use of your Fluke 87V Max multimeter.

Figure 1: Fluke 87V MAX DMM and PVLEAD1 MC4 Test Leads Kit. This image shows the multimeter and its specialized MC4 test leads, highlighting its suitability for solar applications.
2. Hvad er der i æsken
Upon unboxing your Fluke 87V Max, verify that all components are present:
- Fluke 87V Max Multimeter
- Test Leads (TL175 soft, flexible, retractable leads)
- Alligator Clips (screw onto leads)
- Temperatursonde
- Removable Holster (doubles as a test probe holder)

Figure 2: All components included with the Fluke 87V Max. This image displays the multimeter, test leads, alligator clips, and other accessories that come with the product.
3. Opsætning
Before first use, ensure the multimeter is properly set up and test leads are connected securely.
- Batteri installation: The Fluke 87V Max typically comes with batteries pre-installed. If not, refer to the battery compartment on the rear of the device for proper installation. Ensure correct polarity.
- Attaching the Holster: The removable holster provides protection and can be used as a test probe holder. Slide the multimeter into the holster until it fits snugly.
- Tilslutning af testledninger: Insert the banana plugs of the test leads into the appropriate input jacks on the multimeter. For most measurements, the black lead connects to the COM (common) jack and the red lead connects to the VÅHz or mA/µA jack, depending on the measurement type. For current measurements up to 10A, use the 10A MAX FUSED jack.
- MC4 Test Lead Bundle: For solar PV array measurements, connect the specialized MC4 test leads to the meter. These leads are designed for direct connection to MC4 connectors found on solar panels.

Figure 3: A person connecting MC4 test leads. This image illustrates the process of connecting the specialized MC4 test leads, crucial for solar photovoltaic system measurements.
4. Operating the Multimeter
The Fluke 87V Max offers a wide range of measurement functions. Always select the correct function and range before making a measurement.
4.1. Grundlæggende målinger
- Voltage (V): Turn the rotary switch to VÅHz. Select AC or DC voltage using the yellow function button if necessary. Connect leads in parallel with the circuit.
- Nuværende (A): Turn the rotary switch to mA/µA or 10A. Select AC or DC current. Connect leads in series with the circuit. Ensure the correct input jack is used (400mA FUSED or 10A MAX FUSED).
- Resistance (Å): Turn the rotary switch to VÅHz and press the yellow button to select resistance. Connect leads across the component.
- Kontinuitet: Turn the rotary switch to VÅHz and press the yellow button to select continuity. The meter will beep if there is a continuous path.
4.2. Avancerede funktioner
- True-RMS: The 87V Max is a True-RMS meter, providing accurate readings for non-sinusoidal waveforms, which are common in modern electrical systems.
- Min/Max/Average: Press the MIN MAX button to capture minimum, maximum, and average readings over time.
- Peak Min/Max: Use this function to capture transient peaks as fast as 250 µs.
- Frequency (Hz) and Duty Cycle (%): Measure the frequency and duty cycle of AC signals.
- Kapacitans: Measure the capacitance of capacitors.
- Temperatur: Use the included temperature probe to measure temperature.

Figure 4: The Fluke 87V Max in an operational setting. This image shows the multimeter being used to take measurements within an electrical panel, demonstrating its practical application.
5. Vedligeholdelse
Proper maintenance ensures the longevity and accuracy of your Fluke 87V Max multimeter.
- Rensning: Rengør sagen med adamp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and free of scratches.
- Udskiftning af batteri: When the battery indicator appears on the display, replace the batteries promptly. Refer to the battery compartment for instructions. Always use the specified battery type.
- Inspektion af testledninger: Regularly inspect test leads for any signs of damage, such as cuts, cracks, or frayed insulation. Replace damaged leads immediately to ensure safety and accurate measurements.
- Opbevaring: Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided holster or a suitable carrying case for protection.

Figure 5: The Fluke 87V Max in a wet environment. This image shows the multimeter and a tool bag exposed to rain, demonstrating its IP67 rating for water and dust resistance.

Figure 6: The Fluke 87V Max undergoing a water spray test. This image visually confirms the multimeter's waterproof capabilities, reinforcing its durability in challenging conditions.
6. Fejlfinding
If you encounter issues with your Fluke 87V Max, consider the following common troubleshooting steps:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Intet display eller svagt display | Lavt eller dødt batteri | Udskift batterierne. |
| Forkerte aflæsninger | Incorrect function/range selected; Damaged test leads; Dirty input jacks | Verify function/range; Inspect and replace leads; Clean input jacks. |
| No continuity beep | Open circuit; Incorrect function selected | Check circuit for breaks; Ensure continuity function is selected. |
| Måleren tænder ikke | Batteries incorrectly installed; Faulty unit | Reinstall batteries correctly; Contact Fluke support if issue persists. |
7. Specifikationer
Key technical specifications for the Fluke 87V Max True-RMS Digital Multimeter:
- Produktdimensioner: 10.25 x 6.5 x 5 tommer
- Varens vægt: 16 ounces (1 pund)
- Modelnummer: FLK-87VMAX-PVLEAD1
- Fabrikant: Fluke
- Strømkilde: Corded Electric (refers to internal power source, not external cord)
- Stil: w/ MC4 Test Lead Bundle
- Farve: Gul
- Faldmodstand: Withstands drops up to 4-meters (13 feet)
- Miljøvurdering: Waterproof, dustproof IP67 case
- Sikkerhedsvurdering: CAT III 1000 V / CAT IV 600 V
- Prøveemner: MC4 test lead sets designed for 4mm banana plugs, rated to CAT III 1000 V / CAT IV 600 V
8. Garanti og support
Fluke products are known for their reliability and durability. For specific warranty information and technical support, please refer to the official Fluke website or contact their customer service department. Keep your purchase receipt as proof of ownership.
For further assistance or to register your product, visit the Official Fluke Webwebsted.