1. Introduktion
Thank you for choosing the JFA Power Supply and Charger 200A X-LI. This intelligent ventilation battery charge system is designed to provide stable and efficient power for various applications, particularly for automotive sound systems, maintaining up to 10,000 WRMS of sound playing. It features advanced functions such as the Super-X voltage boost, Intelligent Charge System (ICS), and comprehensive battery diagnosis. This manual provides essential information for the safe and effective operation, setup, maintenance, and troubleshooting of your device. Please read it thoroughly before use.
2. Vigtige sikkerhedsoplysninger
ADVARSEL: Manglende overholdelse af disse sikkerhedsinstruktioner kan resultere i brand, elektrisk stød, personskade eller beskadigelse af produktet eller ejendom.
- Always disconnect the power supply from the AC outlet before making any connections or disconnections.
- Ensure the product is placed in a well-ventilated area. Do not block ventilation openings.
- Udsæt ikke enheden for vand, fugt eller ekstreme temperaturer.
- This product is designed for specific voltage inputs (90-140Vac / 170-240Vac). Verify your power source matches the device's requirements.
- Avoid short circuits at the output terminals. The device has protection, but prolonged short circuits can cause damage.
- Forsøg ikke at åbne eller reparere enheden. Overlad al service til kvalificeret personale.
- Opbevares utilgængeligt for børn.
3. Produktet er slutview
The JFA 200A X-LI features a compact design with an intuitive display and robust connectivity options. Key components include:
- Digital skærm: Viser outputvolumentage, current, and operational status.
- Kontrolknapper: For selecting output voltage and activating functions like Super-X.
- Ventilationssystem: Intelligent fan with dynamic PWM control for optimal cooling.
- Input/output terminaler: For AC power input and DC power output to the battery/system.
Figur 1: Forside view of the JFA Power Supply and Charger 200A X-LI, highlighting the digital display and control panel. The device is black with red accents on the sides, featuring the JFA logo and X-LINE branding.
Figur 2: Side view of the JFA Power Supply and Charger 200A X-LI, illustrating the integrated ventilation fan on the left side and the compact, robust casing-design.
4. Opsætning
4.1 Udpakning
Carefully remove the power supply from its packaging. Inspect the device for any signs of damage during transit. Retain the packaging for future storage or transport.
4.2 Placering
Place the JFA 200A X-LI on a stable, flat surface. Ensure there is adequate space around the unit for proper ventilation. Do not place it on soft surfaces that could block the fan or air vents. Avoid direct sunlight, heat sources, and areas with high humidity or dust.
4.3 Tilslutning til vekselstrøm
- Verify that your AC power source is within the acceptable range for the device: 90 to 140Vac or 170 to 240Vac (Automatic Bi-volt).
- Connect the provided AC power cord to the input port on the power supply.
- Sæt den anden ende af netledningen i en jordet stikkontakt.
4.4 Connecting to Battery/Audio System
- Ensure the power supply is turned off and disconnected from the AC outlet before making DC connections.
- Connect the positive (+) output terminal of the power supply to the positive (+) terminal of your battery or audio system.
- Connect the negative (-) output terminal of the power supply to the negative (-) terminal of your battery or audio system.
- Ensure all connections are secure and free from corrosion. Loose connections can cause overheating or poor performance.
5. Betjeningsvejledning
5.1 Tænd/sluk
Once all connections are secure, plug the AC power cord into the wall outlet. The device will power on automatically. To turn off, simply disconnect the AC power cord from the wall outlet.
5.2 Selecting Output Voltage
The JFA 200A X-LI allows you to select from several output voltage options to suit your application. Use the control buttons on the front panel to cycle through the available voltages:
- 12.6V
- 13.0V
- 13.4V
- 13.8V
- 14.0V
- 14.4V
Den valgte voltage will be displayed on the digital screen.
5.3 Intelligent Charge System (ICS) and 3-Stage Opladning
The device features an Intelligent Charge System (ICS) with settings for 13.8V / 14.4V cyclic charging, and a customizable 3-stage slow charge system:
- Højde: Initial charging phase.
- Absorption: Charging at a constant voltage for at oplade batteriet helt.
- Udligning: Balancerer cellevolumentages in a battery.
The system automatically manages the charging process to optimize battery life and performance.
5.4 Super-X Function (15V Boost)
The Super-X function allows the power supply to temporarily raise the output voltage to 15V. This provides maximum performance to connected amplifiers for short durations. Consult your amplifier's specifications before activating this function to ensure compatibility and prevent damage.
5.5 Battery Diagnosis (CCA Meter)
The JFA 200A X-LI includes an exclusive battery diagnosis function. In just 10 seconds, it can perform a real analysis of the battery's load accumulation capacity using a CCA (Cold Cranking Amps) meter. This helps assess the health and performance of your connected battery.
5.6 Forståelse af displayaflæsninger
Det digitale display giver information i realtid:
- Voltmeter: Viser den aktuelle udgangsvolumentage. Accuracy: 99%.
- Amperemeter: Displays the current output amperage. Accuracy: 96%.
Monitor these readings to ensure stable operation and proper charging.
6. Vedligeholdelse
6.1 Rengøring
Regularly clean the exterior of the power supply with a soft, dry cloth. Do not use liquid cleaners or aerosols. Ensure the device is unplugged before cleaning.
6.2 Ventilation Checks
Periodically check the ventilation openings and fan for any dust or debris accumulation. Use a soft brush or compressed air to gently clear any obstructions. A clear ventilation path is crucial for the intelligent ventilation system to operate effectively and prevent overheating.
6.3 Opbevaring
If storing the device for an extended period, disconnect it from all power sources and store it in a cool, dry place, away from direct sunlight and extreme temperatures. It is recommended to use the original packaging for protection.
7. Fejlfinding
This section addresses common issues you might encounter with your JFA Power Supply and Charger 200A X-LI.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | No AC power; Loose power cord; Faulty outlet. | Check AC power connection. Try a different outlet. Ensure power cord is fully inserted. |
| Ingen output voltage/strøm. | Loose DC connections; Output short circuit; Overload protection activated. | Check positive and negative DC connections. Inspect for short circuits. Reduce load if overloaded. |
| Enheden overophedes. | Blokeret ventilation; For stor belastning; Høj omgivelsestemperatur. | Ensure ventilation openings are clear. Reduce load. Move device to a cooler environment. |
| Inaccurate Voltmeter/Ammeter readings. | Calibration issue; External interference. | While accuracy is high, if persistent issues, contact support. Ensure no strong electromagnetic interference nearby. |
| Batteriet oplades ikke korrekt. | Forkert voltage setting; Battery fault; Loose connections. | Verify correct output voltage is selected. Use battery diagnosis function. Check battery health. Secure connections. |
Beskyttelsesfunktioner:
The JFA 200A X-LI is equipped with several protection mechanisms:
- Excess of Charge Protection: Prevents overcharging of connected batteries.
- Short in Output Protection: Automatically shuts down in case of a short circuit at the output terminals.
- Temperaturbeskyttelse: Prevents damage from overheating by reducing output or shutting down.
If a protection feature is activated, disconnect the power supply, resolve the underlying issue, and then reconnect.
8. Specifikationer
| Feature | Detalje |
|---|---|
| Indgang AC | 90 til 140Vac / 170 til 240Vac (automatisk bi-volt) |
| Consumption with maximum charge | 3000W |
| Maksimal udgangsstrøm | 200 Amperes |
| Udgang Voltage Valgbar | 12.6V / 13.0V / 13.4V / 13.8V / 14.0V / 14.4V |
| Intelligent Charging System (ICS) | 13.8 / 14.4 cyklisk |
| 3-Stage Slow Charge System | Customizable (Elevation / Absorption / Equalization) |
| Smart køler | Smart ventilation system - PWM dynamic control |
| Voltmeter nøjagtighed | 99 % |
| Amperemeter nøjagtighed | 96 % |
| Beskyttelser | Excess of charge / Short in output / Temperature |
| Produktmål (B x H x D) | 317 mm x 172 mm x 95 mm (ca. 12.48 x 6.77 x 3.74 tommer) |
| Varens vægt | 2.650 Kg (approx. 5.84 pounds) |
| Modelnummer | 200AX |
| ASIN | B0BHFBFHJR |
9. Garanti og support
This product is manufactured by JFA and is subject to the manufacturer's standard warranty terms. Please refer to the warranty card included with your purchase or visit the official JFA website for detailed warranty information, including coverage period and conditions.
For technical support, service, or inquiries regarding your JFA Power Supply and Charger 200A X-LI, please contact the manufacturer or your authorized dealer. Have your product model number (200AX) and ASIN (B0BHFBFHJR) ready when contacting support.
For mere information kan du besøge produktside på Amazon.