1. Introduktion
Thank you for choosing the Akicon Range Hood Insert 48 Inch, Model 19IL. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new kitchen appliance. Please read all instructions carefully before use and retain this manual for future reference.

Billede: Forside view of the Akicon Range Hood Insert 48 Inch.
2. Sikkerhedsoplysninger
For at mindske risikoen for brand, elektrisk stød eller personskade skal du overholde følgende:
- Install this range hood in accordance with all local codes and ordinances.
- Afbryd altid strømmen til emhætten ved afbryderen eller sikringsboksen før service.
- Sørg for tilstrækkelig ventilation for at forhindre tilbagetræk af forbrændingsgasser fra andre brændselsapparater.
- Clean grease filters frequently. Grease accumulation can lead to fire.
- Never leave surface units unattended at high settings. Boil-overs cause smoking and greasy spill-overs that may ignite.
- Brug køkkengrej af passende størrelse på hver overflade.
3. Pakkens indhold
Kontroller, at alle varer er inkluderet i pakken:
- Indsæt emhætte
- Installationsskruer
- Baffelfiltre
- Installationsmanual
- LED Lights (extra 3pcs of 3000K warm Dimmable LED lights included)
4. Specifikationer
| Feature | Specifikation |
|---|---|
| Model info | 19IL |
| Luftmængde kapacitet | 1200 kubikfod pr. minut (CFM) |
| Materiale | Rustfrit stål |
| Støjniveau | Less than 65 Decibels (at highest speed) |
| Monteringstype | Indbygget montering / Indsatsmontering |
| Kontroltype | Tryk knap |
| Voltage | 120 volt (AC) |
| Antal hastigheder | 4 |
| Lyskildetype | LED (3pcs of 5500K, extra 3pcs of 3000K dimmable) |
| Filtertype | Baffel (tåler opvaskemaskine) |
| Produktdimensioner | 19 x 46.4 x 12.6 cm (D x B x H) |
| Varens vægt | 72.8 pund |
| Certificering | ETL Certificeret |

Image: Dimensional diagram of the Akicon Range Hood Insert 48 Inch (Model NX-19IL-48).
5. Opsætning og installation
Installation of the Akicon Range Hood Insert requires careful attention to detail and adherence to safety guidelines. It is recommended that installation be performed by a qualified professional.
5.1 Kontrol før installation
- Unpack the range hood and inspect for any shipping damage.
- Ensure all necessary components listed in Section 3 are present.
- Verify that the installation area meets the dimensional requirements shown in the specifications diagram.
- Confirm that the electrical supply matches the product specifications (120V AC).
5.2 Mounting the Insert
The range hood is designed for built-in or insert mounting. Refer to the detailed installation instructions provided in the separate Installation Manual included with your product for specific steps on cutting the opening, securing the unit, and connecting the ductwork.
A professional instruction manual and video are available to assist with installation. Please consult these resources for comprehensive guidance.
6. Betjeningsvejledning
The Akicon Range Hood Insert features a user-friendly push-button control panel for easy operation of its functions.
6.1 Kontrolpanel overview

Billede: Detaljeret view of the control panel and key features.
6.2 Justering af ventilatorhastighed
- Press the Power button to turn the fan on/off.
- Use the '+' and '-' buttons to cycle through the 4 fan speeds (1-4). The current speed will be displayed numerically.
- The 48-inch model offers a maximum airflow of 1200 CFM.
6.3 Dimmable LED Lights
- Press the Light button to turn the LED lights on/off.
- Press and hold the Light button for 3 seconds to adjust the brightness. There are four brightness levels available.
6.4 Forsinket automatisk nedlukning
- While the fan is running, press and hold the '-' button for 3 seconds to activate the delayed shutdown timer.
- The display will flash a number (1-9), indicating minutes. Use the '+' and '-' buttons to set the desired delay time (1 to 9 minutes).
- Once set, the fan and lights will automatically turn off after the selected delay.
6.5 Betjeningsvideo
Video: This video demonstrates the operation of the control buttons for the Akicon 19IL Series Insert Range Hood, including power, speed adjustment, dimmable LED lights, and delayed automatic shutdown function.
7. Vedligeholdelse
Regelmæssig vedligeholdelse sikrer optimal ydeevne og levetid for din emhætte.
7.1 Rengøring af baffelfiltre
- The stainless steel baffle filters are dishwasher-safe and easily removable for cleaning.
- To remove, locate the handles on each filter, pull down slightly, and slide out.
- Clean filters in a dishwasher or by hand with warm, soapy water. Ensure they are completely dry before re-installing.
- After 30 hours of operation, the cleaning reminder indicator "C" will flash, signaling that the grease filters need cleaning. Press and hold the "+" button for more than 3 seconds in a non-operation status to eliminate the flashes and reset the timer.

Image: Dishwasher-safe baffle filters for easy cleaning.
7.2 Udvendig rengøring
- Clean the exterior surfaces with a soft cloth and a non-abrasive stainless steel cleaner.
- Avoid using abrasive pads or harsh chemicals that could scratch or damage the finish.
8. Fejlfinding
If you experience issues with your range hood, consult the following common troubleshooting tips:
- Ventilatoren kører ikke: Check if the power cord is securely plugged in and if the circuit breaker is on. Ensure the power button on the control panel has been pressed.
- Dårlig sugeevne: Verify that the baffle filters are clean and properly installed. Check for any obstructions in the ductwork. Ensure the fan speed is set appropriately for cooking conditions.
- Lys virker ikke: Check if the light button has been pressed. Ensure the LED lights are securely in place. If individual lights are out, they may need replacement.
- Overdreven støj: Ensure the unit is securely mounted and all screws are tightened. Check for any loose parts or obstructions in the fan blades.
For persistent issues, please contact Akicon Customer Support.
9. Garanti og support
9.1 Garantioplysninger
This Akicon Range Hood Insert comes with a 3 års begrænset garantiSe venligst garantikortet, der er inkluderet i din pakke, for at se de fulde vilkår og betingelser.
9.2 Kundesupport
For any questions, problems, or missing parts, please contact Akicon Customer Service:
- Timer: 8-6 EST, mandag-fredag
- Ring til: +1(302)213-4406
- E-mail: service@akiconshop.com
- Webwebsted: WWW.AKICONSHOP.COM