1. Introduktion

The DIGITEN TTC-1003 is a versatile 3-stage outlet temperature controller designed for precise environmental management. It features two temperature-controlled outlets and one timer-controlled outlet, allowing for independent regulation of heating, cooling, and lighting cycles. This device is suitable for a wide range of applications, including reptile habitats, incubators, greenhouses, mushroom cultivation, and home brewing. This manual provides detailed instructions for the safe and effective operation of your TTC-1003 controller.

DIGITEN TTC-1003 Reptile Temperature Controller with three outlets and two temperature probes.

Figure 1: DIGITEN TTC-1003 Temperature Controller

2. Sikkerhedsoplysninger

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product.

3. Produktet er slutview

3.1 Komponenter

3.2 Nøglefunktioner

DIGITEN TTC-1003 controller highlighting timing function, C/F switchable, high/low temperature alarm, and heating/cooling mode.

Figure 2: Key Features of the TTC-1003

4. Opsætningsvejledning

4.1 Indledende placering

  1. Choose a dry, stable location for the controller unit, away from direct sunlight or heat sources.
  2. The unit can be wall-mounted using the integrated hanging slot on the back.
DIGITEN TTC-1003 controller mounted on a wall, showing its compact design.

Figure 3: Wall-Mounted Installation

4.2 Connecting Probes and Devices

  1. Plug the two temperature sensor probes into the designated ports on the top of the controller.
  2. Position the sensor probes in the environment where temperature monitoring is required. Ensure they are not directly exposed to heating elements or water if not intended.
  3. Plug your heating or cooling devices into OUT1 and OUT2. These outlets are temperature-controlled.
  4. Plug your lighting or other timed devices into OUT3. This outlet is timer-controlled.
  5. Plug the controller's power cord into a standard electrical outlet. The LCD display will illuminate.
DIGITEN TTC-1003 controller used in various applications including reptile habitats, aquariums, brewing, greenhouses, germination, and incubators.

Figur 4: Eksample Applications and Connections

5. Betjeningsvejledning

The controller features a large LCD display and three buttons: SÆT, UR, og OP/NED pile.

5.1 Indstilling af aktuel tid

  1. Tryk og hold på UR button for 3 seconds until the hour digit flashes.
  2. Brug OP/NED pile for at justere timen.
  3. Trykke UR igen for at gå til minutcifferet, og juster derefter med OP/NED pile.
  4. Trykke UR for at bekræfte og afslutte.

5.2 Temperature Control (Outlets 1 & 2)

Outlets 1 and 2 are independently controlled for temperature. Each can be set for heating or cooling mode with specific ON/OFF temperatures and operating times.

  1. Tryk og hold på SÆT button for 3 seconds to enter programming mode. The display will show 'OUT1' or 'OUT2' and the first setting will flash.
  2. Brug OP/NED pile to select 'OUT1' or 'OUT2'. Press SÆT for at bekræfte.
  3. Indstil ON-tid: The 'ON' time will flash. Use OP/NED pile for at indstille timen, og tryk derefter på SÆT to set minutes. This is the time when temperature control for this outlet begins.
  4. Sluk-tidspunkt: The 'OFF' time will flash. Use OP/NED pile for at indstille timen, og tryk derefter på SÆT to set minutes. This is the time when temperature control for this outlet ends.
  5. Set ON Temperature: The 'ON Temp' will flash. Use OP/NED pile to set the temperature at which the connected device turns ON.
  6. Set OFF Temperature: The 'OFF Temp' will flash. Use OP/NED pile to set the temperature at which the connected device turns OFF.
  7. Determine Mode (Heating/Cooling):
    • If ON Temp < OFF Temp: The controller operates in Opvarmningstilstand. The device turns on when the temperature drops to ON Temp and turns off when it reaches OFF Temp.
    • If ON Temp > OFF Temp: The controller operates in Køletilstand. The device turns on when the temperature rises to ON Temp and turns off when it reaches OFF Temp.
  8. Trykke SÆT to cycle through additional settings (High Alarm, Low Alarm, Calibration) or press UR for at gemme og afslutte.
LCD display showing programming for Outlet 1 in heating mode and Outlet 2 in cooling mode, with time and temperature settings.

Figure 5: Temperature Control Programming Example

5.3 Timer Control (Outlet 3)

Outlet 3 operates as a simple timer, allowing for two independent ON/OFF periods within a 24-hour cycle.

  1. Tryk og hold på SÆT button for 3 seconds to enter programming mode.
  2. Brug OP/NED pile to select 'OUT3'. Press SÆT for at bekræfte.
  3. Indstil første tændingstidspunkt: The 'ON' time for the first period will flash. Adjust with OP/NED pile og bekræft med SÆT.
  4. Indstil første slukningstidspunkt: The 'OFF' time for the first period will flash. Adjust with OP/NED pile og bekræft med SÆT.
  5. Gentag trinene for Second ON Time og Second OFF Time if a second timed period is desired. If not, set the second ON time to be the same as the second OFF time to disable it.
  6. Trykke UR for at gemme og afslutte.
LCD display showing programming for Outlet 3 with two time periods for cycle function.

Figure 6: Timer Control Programming Example for Outlet 3

5.4 Valg af temperaturenhed (°C/°F)

To switch between Celsius and Fahrenheit, briefly press the Pil op button while in normal operating mode.

5.5 High/Low Temperature Alarms (AH/AL)

You can set high and low temperature alarms for Outlets 1 and 2 to be notified if the temperature goes outside your desired range.

  1. Enter programming mode for OUT1 or OUT2 (as described in 5.2).
  2. After setting ON/OFF temperatures, press SÆT until 'AH' (High Alarm) flashes. Use OP/NED pile to set the desired high temperature limit.
  3. Trykke SÆT until 'AL' (Low Alarm) flashes. Use OP/NED pile to set the desired low temperature limit.
  4. Trykke UR for at gemme og afslutte.

6. Vedligeholdelse

Regular maintenance ensures the longevity and accuracy of your DIGITEN TTC-1003 controller.

Close-up of the waterproof temperature probe submerged in water.

Figure 7: Waterproof Temperature Probe

7. Fejlfinding

If you encounter issues with your controller, refer to the table below for common problems and solutions.

ProblemMulig årsagLøsning
Skærmen er tom eller tænder ikke.Ingen strømforsyning.Check if the controller is properly plugged into a live outlet. Verify the power outlet is functional.
Heating/Cooling device (OUT1/OUT2) not turning on/off.Incorrect temperature settings (ON Temp/OFF Temp).
Incorrect time period settings.
Enhedsfejl.
Review and adjust ON/OFF temperatures and time periods. Ensure the ON/OFF temperatures are set correctly for heating (ON < OFF) or cooling (ON > OFF). Test the connected device directly in a wall outlet.
Timed device (OUT3) not turning on/off.Incorrect ON/OFF times for OUT3.Verify the programmed ON/OFF times for Outlet 3. Ensure the current time on the controller is accurate.
Temperaturaflæsningerne er unøjagtige.Probe placement or damage.
Kalibrering nødvendig.
Ensure probes are correctly positioned and not directly touching heating elements. Check probes for visible damage. Use the calibration setting (refer to section 5.5) to adjust the temperature reading if necessary (within +/- 12°F). Note that readings are typically accurate within 1-2°F.
Indstillinger går tabt efter strømafbrydelsetage.This should not occur as the device has memory backup.If settings are consistently lost, contact customer support.

8. Specifikationer

FeatureDetalje
ModelnavnTTC-1003
MærkeDIGITEN
Temperaturkontrolområde14°F ~ 248°F (-10°C ~ 120°C)
Voltage100-240V AC
Nominel strøm15A Maks
Wattage2200W
Display TypeLCD med baggrundsbelysning
KontroltypeTryk knap
ForbindelsesteknologiForbundet
Varens vægt1.03 pund (ca. 0.47 kg)
Pakkedimensioner6.54 x 6.34 x 2.05 tommer

9. Garanti og support

9.1 Produktgaranti

DIGITEN provides a one-year warranty for any quality problems with this product. Please retain your proof of purchase for warranty claims.

9.2 Kundesupport

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact DIGITEN customer support. You can find contact information and additional resources by visiting the official DIGITEN store:

Visit the DIGITEN Store on Amazon

Relaterede dokumenter - TTC-1003

Preview Digiten TTC-1003 Temperaturregulator med Timer Brugermanual
Brugermanual til Digiten TTC-1003 temperaturregulator med timer, en termostat med 3 udgange designet til kæledyrsopdrættere og miljøstyring. Lær om dens funktioner, specifikationer og hvordan du konfigurerer varme-, køle- og timerfunktioner for optimal kæledyrskomfort.
Preview Brugermanual og specifikationer til Digiten DTC-101 / DTC-151 digital temperaturregulator
Omfattende guide til de digitale temperaturregulatorer Digiten DTC-101 og DTC-151, med detaljerede oplysninger om funktioner, opsætning, betjening, tekniske specifikationer og fejlfinding for præcis temperaturstyring.
Preview Brugermanual til DIGITEN WTC100/WTC200 trådløs termostat
Brugermanual til de trådløse DIGITEN WTC100 og WTC200 termostater, der indeholder oplysninger om opsætning, betjening, specifikationer og fejlfinding til temperaturstyring i køle- og varmeapplikationer.
Preview DIGITEN DHTC-1011 Temperatur- og fugtighedsregulator Brugermanual
Brugermanual til DIGITEN DHTC-1011 temperatur- og fugtighedsregulatoren, med detaljerede oplysninger om funktioner, specifikationer, indstillingsvejledning og fejlfinding.
Preview DIGITEN WTC1001 Trådløs Termostat Brugermanual og Specifikationer
Omfattende guide til DIGITEN WTC1001 trådløs termostat, der dækker funktioner, specifikationer, betjening, installation, garanti og FCC-overholdelse. Lær, hvordan du styrer dine varme- og kølesystemer effektivt.
Preview Brugermanual til DIGITEN DTC-310 og DTC-315 termostat
Brugermanual til de elektroniske temperaturregulatorer DIGITEN DTC-310 og DTC-315, med detaljerede oplysninger om funktioner, specifikationer, opsætning og fejlfinding.