Indledning
Thank you for choosing the SKS Germany Air X-Plorer 10.0 Floor Pump. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new floor pump. Please read these instructions carefully before first use and retain them for future reference.
Produktegenskaber
- Maksimalt tryk: 144 psi / 10 bar, suitable for various tire types.
- Ventilkompatibilitet: Equipped with the new MV EASY head, compatible with Presta, Schrader, and Dunlop valves.
- Luftvolumen: Delivers 476cc of air pressure per stroke for efficient inflation.
- Dimensioner: Height 710mm, Hose Length 1200mm, Gauge 63mm for clear pressure readings.
- Konstruktion: Features a durable steel tube, stable steel base, and a comfortable soft-touch grip.
- Oprindelse: Manufactured in Germany, ensuring quality and precision.

Figur 1: Front view of the SKS Germany Air X-Plorer 10.0 Floor Pump, showcasing its design and integrated pressure gauge.
Opsætning
- Udpakning: Carefully remove the pump from its packaging. Inspect for any signs of damage.
- Placering: Place the pump on a flat, stable surface. Ensure the base is fully supported to prevent tipping during use.
- Slangestyring: The hose is typically stored securely on the pump. Unclip it from its storage position before use.

Figur 2: Vinklet view of the pump, showing the hose neatly stored and the stable base.
Betjeningsvejledning
1. Preparing the Tire Valve
- Presta ventil: Skru den lille knurled nut at the top of the valve stem. Press down briefly to release a small amount of air, ensuring the valve is open.
- Schrader ventil: No special preparation is needed.
- Dunlop Valve: Ensure the valve cap is removed.
2. Attaching the MV EASY Head
The MV EASY head is designed for universal compatibility. It automatically adapts to Presta, Schrader, and Dunlop valves.
- Push the MV EASY head firmly onto the tire valve.
- Flip the orange lever on the MV EASY head to the locked position (usually perpendicular to the valve stem) to secure it.

Figur 3: Nærbillede view of the MV EASY valve head, showing its design for universal valve compatibility.

Figur 4: Side view of the MV EASY valve head, highlighting the orange locking lever in its open position.
3. Inflating the Tire
- Place your feet on the pump's base to stabilize it.
- Hold the handle firmly and push it down smoothly and completely.
- Pull the handle back up to its full extension. Repeat this pumping motion.
- Monitor the pressure gauge on the base of the pump. Inflate the tire to the recommended pressure specified by the tire manufacturer (usually found on the tire sidewall).
4. Detaching the MV EASY Head
- Once the desired pressure is reached, flip the orange lever on the MV EASY head back to the unlocked position.
- Carefully pull the head straight off the valve stem.
- For Presta-ventiler skal du skrue knurled nut back down to seal the valve. Replace any valve caps.
Opretholdelse
- Rensning: Wipe the pump body and hose with a damp cloth after use to remove dirt and grime. Avoid harsh chemicals.
- Hose and Head Inspection: Periodically check the hose for cracks or damage and the valve head for wear. Replace if necessary to ensure optimal performance.
- Opbevaring: Store the pump in a dry place, away from direct sunlight and extreme temperatures. Ensure the hose is neatly stored to prevent kinks.
Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Pumpen pumper ikke dækket op. | Valve head not properly attached or locked. Valve stem not open (Presta). | Ensure the MV EASY head is pushed firmly onto the valve and the orange lever is in the locked position. For Presta valves, ensure the knurled nut is unscrewed and briefly pressed. |
| Air leaks from valve head during pumping. | Improper attachment. Worn valve head seal. | Re-attach the MV EASY head, ensuring a tight seal and locked lever. Inspect the rubber seal inside the valve head for wear and replace if necessary. |
| Pressure gauge not registering. | Valve head not properly attached. Gauge malfunction. | Verify proper valve head attachment. If the issue persists, contact customer support. |
| Pump handle feels loose or sticky. | Internal lubrication needed or internal component wear. | Contact customer support for guidance on internal maintenance or repair. |
Specifikationer
| Mærke | SKS |
| Modelnavn | Air-x-plorer 10.0 |
| Varenummer | 11762 |
| Materiale | Legeret stål |
| Farve | Sort |
| Varens vægt | 4.5 pund (2.04 kg) |
| Maksimalt tryk | 144 PSI / 10 bar |
| Air Volume per Stroke | 476cc |
| Højde | 710 mm |
| Slange længde | 1200 mm |
| Måler diameter | 63 mm |
| Ventilkompatibilitet | Presta, Schrader, Dunlop (MV EASY head) |
| Driftstilstand | Manuel |
| Fabrikant | SKS Germany |
Garanti og support
The SKS Germany Air X-Plorer 10.0 Floor Pump comes with a 2-year manufacturer's defect warranty. Denne garanti dækker fejl i materialer og udførelse ved normal brug.
For warranty claims, technical support, or inquiries regarding replacement parts, please contact SKS Germany customer service through their official website or your point of purchase. Please have your proof of purchase and the product model name (Air-x-plorer 10.0) available when contacting support.





