SKS Air-x-plorer 10.0

SKS Germany Air X-Plorer 10.0 Gulvpumpe Brugsanvisning

Model: Air-x-plorer 10.0

Indledning

Thank you for choosing the SKS Germany Air X-Plorer 10.0 Floor Pump. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new floor pump. Please read these instructions carefully before first use and retain them for future reference.

Produktegenskaber

SKS Germany Air X-Plorer 10.0 Floor Pump, front view

Figur 1: Front view of the SKS Germany Air X-Plorer 10.0 Floor Pump, showcasing its design and integrated pressure gauge.

Opsætning

  1. Udpakning: Carefully remove the pump from its packaging. Inspect for any signs of damage.
  2. Placering: Place the pump on a flat, stable surface. Ensure the base is fully supported to prevent tipping during use.
  3. Slangestyring: The hose is typically stored securely on the pump. Unclip it from its storage position before use.
SKS Germany Air X-Plorer 10.0 Floor Pump, angled view with hose and base

Figur 2: Vinklet view of the pump, showing the hose neatly stored and the stable base.

Betjeningsvejledning

1. Preparing the Tire Valve

2. Attaching the MV EASY Head

The MV EASY head is designed for universal compatibility. It automatically adapts to Presta, Schrader, and Dunlop valves.

  1. Push the MV EASY head firmly onto the tire valve.
  2. Flip the orange lever on the MV EASY head to the locked position (usually perpendicular to the valve stem) to secure it.
Close-up of SKS MV EASY valve head

Figur 3: Nærbillede view of the MV EASY valve head, showing its design for universal valve compatibility.

Side view of SKS MV EASY valve head with orange lever

Figur 4: Side view of the MV EASY valve head, highlighting the orange locking lever in its open position.

3. Inflating the Tire

  1. Place your feet on the pump's base to stabilize it.
  2. Hold the handle firmly and push it down smoothly and completely.
  3. Pull the handle back up to its full extension. Repeat this pumping motion.
  4. Monitor the pressure gauge on the base of the pump. Inflate the tire to the recommended pressure specified by the tire manufacturer (usually found on the tire sidewall).

4. Detaching the MV EASY Head

  1. Once the desired pressure is reached, flip the orange lever on the MV EASY head back to the unlocked position.
  2. Carefully pull the head straight off the valve stem.
  3. For Presta-ventiler skal du skrue knurled nut back down to seal the valve. Replace any valve caps.

Opretholdelse

Fejlfinding

ProblemMulig årsagLøsning
Pumpen pumper ikke dækket op.Valve head not properly attached or locked. Valve stem not open (Presta).Ensure the MV EASY head is pushed firmly onto the valve and the orange lever is in the locked position. For Presta valves, ensure the knurled nut is unscrewed and briefly pressed.
Air leaks from valve head during pumping.Improper attachment. Worn valve head seal.Re-attach the MV EASY head, ensuring a tight seal and locked lever. Inspect the rubber seal inside the valve head for wear and replace if necessary.
Pressure gauge not registering.Valve head not properly attached. Gauge malfunction.Verify proper valve head attachment. If the issue persists, contact customer support.
Pump handle feels loose or sticky.Internal lubrication needed or internal component wear.Contact customer support for guidance on internal maintenance or repair.

Specifikationer

MærkeSKS
ModelnavnAir-x-plorer 10.0
Varenummer11762
MaterialeLegeret stål
FarveSort
Varens vægt4.5 pund (2.04 kg)
Maksimalt tryk144 PSI / 10 bar
Air Volume per Stroke476cc
Højde710 mm
Slange længde1200 mm
Måler diameter63 mm
VentilkompatibilitetPresta, Schrader, Dunlop (MV EASY head)
DriftstilstandManuel
FabrikantSKS Germany

Garanti og support

The SKS Germany Air X-Plorer 10.0 Floor Pump comes with a 2-year manufacturer's defect warranty. Denne garanti dækker fejl i materialer og udførelse ved normal brug.

For warranty claims, technical support, or inquiries regarding replacement parts, please contact SKS Germany customer service through their official website or your point of purchase. Please have your proof of purchase and the product model name (Air-x-plorer 10.0) available when contacting support.

Relaterede dokumenter - Air-x-plorer 10.0

Preview SKS Air-X-Plorer 10.0 Gulvpumpe Manual
Officiel manual til SKS Air-X-Plorer 10.0 gulvpumpen, der beskriver vedligeholdelses- og reparationsprocedurer for måler, tætningsmanchet, genvindingssystem og ventiltætninger.
Preview SKS Airkompressor Compact 10.0 Gulvpumpe Manual - Vedligeholdelse og Reparation
Officiel manual til SKS Airkompressor Compact 10.0 gulvpumpe (model 11660). Indeholder detaljerede instruktioner til udskiftning af trykmåler, gummitætningsmanchet, genvindingssystem og ventilpakninger. Indeholder information om ventilkompatibilitet (Schrader, Presta, Dunlop) og maksimalt tryk.
Preview SKS SKSIR360IS Elektrisk induktionskomfur brugermanual
Officiel brugermanual til SKS SKSIR360IS elektrisk induktionskomfur, der indeholder omfattende instruktioner om installation, betjening, sikkerhed, vedligeholdelse og fejlfinding for optimal brug.
Preview SKS Indbygget Køleskab Installationsmanual
Omfattende installationsmanual til SKS indbygget køleskab (modellerne SKSFD4826SP, SKSFD4826MT). Indeholder detaljerede instruktioner, sikkerhedsretningslinjer og specifikationer for korrekt installation.
Preview SKS Dual Fuel Range brugermanual - SKSDR360-serien
Omfattende brugermanual til SKS Dual Fuel-serien, der dækker installation, betjening, sikkerhed og vedligeholdelse af modellerne SKSDR360GS, SKSDR360SS og SKSDR360SIS.
Preview SKS Gaskomfur Brugermanual: SKSGR360GS, SKSGR360S
Omfattende brugermanual til SKS gaskomfurer (modeller SKSGR360GS, SKSGR360S), der dækker sikkerhed, installation, betjening, vedligeholdelse og fejlfinding. Vigtig vejledning til korrekt brug af apparatet.