N1 Critical N1C.L1500

N1 Critical N1C.L1500 1500VA/1350W Lithium-ion rack/tower UPS brugermanual

Model: N1C.L1500

1. Introduktion

The N1 Critical N1C.L1500 is a high-performance 1500VA/1350W Uninterruptible Power Supply (UPS) designed to provide reliable power protection for critical electronic equipment. Featuring advanced Lithium-Ion (LiFePO4) battery technology, this UPS offers extended battery life, higher power density, and improved thermal performance compared to traditional VRLA battery systems. It supports both rackmount and tower configurations, making it versatile for various IT environments.

2. Sikkerhedsinstruktioner

Please read and follow all safety instructions carefully before installing, operating, or servicing the UPS. Failure to comply with these instructions may result in electric shock, fire, or serious injury.

3. Pakkens indhold

Kontroller, at alle genstande er til stede ved udpakning:

4. Produktet er slutview

4.1 Frontpanel

The front panel features the LCD display and control buttons for monitoring and configuring the UPS.

N1 Critical N1C.L1500 UPS Front View

Figur 4.1: Forside view of the N1 Critical N1C.L1500 UPS, showing the integrated LCD display and control buttons.

N1 Critical N1C.L1500 UPS LCD Display

Figure 4.2: Close-up of the N1 Critical N1C.L1500 UPS LCD display, indicating input voltage, battery status, and operational modes.

4.2 Bagpanel

The rear panel provides all necessary connections for input power, protected equipment, and communication interfaces.

N1 Critical N1C.L1500 UPS Rear View with Outlets and Ports

Figur 4.3: Bagside view of the N1 Critical N1C.L1500 UPS, showing six NEMA 5-15R outlets, AC input, circuit protector, USB port, EPO port, and an intelligent slot.

5. Opsætning

5.1 Placering

The N1C.L1500 UPS can be installed in either a rackmount or tower configuration.

Ensure the installation location is well-ventilated, free from excessive heat or moisture, and has stable ambient temperatures.

5.2 Tilslutning til strøm

  1. Connect the supplied input power cord to the AC Input port on the rear panel of the UPS.
  2. Plug the other end of the input power cord into a grounded 120V AC wall outlet.

5.3 Tilslutning af udstyr

  1. Ensure all equipment to be connected to the UPS is turned off.
  2. Plug your critical equipment (computers, servers, network devices) into the NEMA 5-15R outlets on the rear panel of the UPS.
  3. Do not connect surge suppressors or power strips to the UPS outlets, as this may overload the UPS.

5.4 Første opstart

  1. After connecting the UPS to utility power and your equipment, press and hold the power button on the front panel for a few seconds until the UPS powers on.
  2. LCD-displayet lyser, og UPS'en udfører en selvtest.
  3. Once the self-test is complete, the UPS will enter normal operating mode, providing conditioned power to your connected devices.

6. Betjeningsvejledning

6.1 Tænd/sluk

6.2 Forståelse af LCD-skærmen

The LCD display provides real-time information about the UPS status, including input/output voltage, batteriopladningsniveau, belastningsprocenttage, and various operational modes or warnings. Refer to Figure 4.2 for a visual reference.

6.3 Batteribackupdrift

Under en magt outage eller betydelig volumentage fluctuation, the UPS will automatically switch to battery power, providing continuous power to connected equipment. An audible alarm may sound, and the display will indicate battery mode. The duration of backup power depends on the connected load and battery charge level.

6.4 Kommunikationsfunktioner

7. Vedligeholdelse

7.1 Pleje af batterier

The N1C.L1500 utilizes Lithium-Ion (LiFePO4) batteries, which offer a significantly longer lifespan (10-15 years) and better thermal tolerance compared to traditional lead-acid batteries. These batteries are not user-replaceable. For battery service or replacement, contact qualified service personnel.

7.2 Rengøring

Periodically clean the exterior of the UPS with a soft, dry cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow. Do not use liquid or aerosol cleaners.

7.3 Opbevaring

If storing the UPS for an extended period, ensure it is fully charged before storage. Store in a cool, dry environment. Recharge the UPS every 3-6 months to maintain battery health.

8. Fejlfinding

This section provides solutions to common issues you may encounter with the UPS.

ProblemMulig årsagLøsning
UPS'en tænder ikkeNo AC input power; UPS not fully charged; Power button not pressed correctly.Check AC power connection and outlet; Allow UPS to charge for several hours; Press and hold power button firmly.
UPS'en er ofte i batteritilstandUstabil strøm fra elnettet; Følsomhedsindstillingen er for høj.Check utility power quality; Adjust UPS sensitivity setting via software (if available).
Advarsel om overbelastningTilsluttet udstyr overstiger UPS'ens kapacitet.Disconnect non-essential equipment; Reduce the total load to within UPS capacity.
Battery fault indicatorProblem med det interne batteri.Contact N1 Critical support for assistance. Do not attempt to replace the battery yourself.

9. Specifikationer

Technical specifications for the N1 Critical N1C.L1500 UPS:

10. Garanti og support

For warranty information, technical support, or service inquiries, please refer to the official N1 Critical webwebstedet eller kontakt deres kundeserviceafdeling. Gem din købskvittering for at validere garantien.

Relaterede dokumenter - N1C.L1500

Preview Riello UPS NextEnergy: Højeffektiv, skalerbar strømbeskyttelse
Discover the Riello UPS NextEnergy series, a range of advanced Uninterruptible Power Supplies (UPS) designed for mission-critical applications. Offering up to 97% efficiency, transformerless design, and flexible installation, NextEnergy ensures reliable power for data centers, communication networks, and industrial facilities. Explore features like Active Eco mode, peak shaving, and smart battery management.
Preview Vertiv Liebert GXT5 UPS: Intelligent og effektiv strømbeskyttelse | Produkt overview
Udforsk Vertiv Liebert GXT5 UPS-serien, der tilbyder intelligent og effektiv strømbeskyttelse til missionskritiske applikationer.view detaljer om dens funktioner, specifikationer, familie overview, servicepakker, tilbehør og monteringsmuligheder, hvilket fremhæver dets kompakte design, høje effektivitet og avancerede administrationsfunktioner.
Preview N1C LK-serien UPS 5-10kVA driftsmanual
Omfattende betjeningsmanual til N1C LK-serien af ​​5-10 kVA afbrydelsesfri strømforsyningssystemer (UPS). Dækker installation, funktioner, driftstilstande, fejlfinding og specifikationer for pålidelig kritisk strømbeskyttelse.
Preview Vertiv Liebert GXT5 UPS: 15-20 kVA strømbeskyttelse til missionskritiske applikationer
Udforsk Vertiv Liebert GXT5 UPS-serien, der tilbyder 15-20 kVA intelligent, effektiv og pålidelig strømbeskyttelse til missionskritiske applikationer. Funktionerne omfatter online dobbeltkonvertering, effektfaktor med én funktion, høj effektivitet og avancerede styringsfunktioner.
Preview Schrack AVARA Multi Power Modular UPS Brugermanual: 15/25/42 kW til 1 MW
Comprehensive user manual for the Schrack AVARA Multi Power modular UPS series (USMPM 10 – 100 kVA), covering specifications, applications, system configurations, and technical data for models ranging from 15 kW to 1 MW. Essential guide for critical load protection in data centers, e-business, and telecommunications.
Preview KOHLER PW 3000/P1: High-Efficiency Single-Phase UPS | 10 & 20 kVA
Explore the KOHLER PW 3000/P1, a high-efficiency single-phase uninterruptible power supply (UPS) designed for critical power protection. Offering 10 & 20 kVA capacities, advanced features, and 96.6% efficiency, it's ideal for servers, networks, and telecommunications. Learn about its technical specifications, features, and support.