Indledning
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Akai 12000BTU Split Air Conditioner, Model ACMA-A12T3N. Please read this manual thoroughly before using the appliance and retain it for future reference.
The Akai 12000BTU Split Air Conditioner features a T3 Rotary Compressor, designed for high cooling capacity and energy efficiency. It includes an anti-dust filter to improve air quality and humidity control functions.
Vigtige sikkerhedsinstruktioner
Følg altid grundlæggende sikkerhedsforanstaltninger ved brug af elektriske apparater for at reducere risikoen for brand, elektrisk stød og personskade.
- Sørg for, at strømforsyningen matcher voltage angivet på enheden.
- Betjen ikke klimaanlægget med våde hænder.
- Do not insert objects into the air outlet or inlet.
- Hold børn væk fra enheden.
- Afbryd strømmen før rengøring eller servicering.
- Installation skal udføres af kvalificeret personale.
Produktkomponenter
The Akai 12000BTU Split Air Conditioner consists of an indoor unit and an outdoor unit. Key components include:
- Indendørs enhed: Air filter, evaporator, fan, control panel, display.
- Udendørs enhed: Compressor (T3 Rotary), condenser, fan.
- Fjernbetjening: For operating various functions.

Figur 1: Forside view of the Akai 12000BTU Split Air Conditioner indoor unit. It is white with the AKAI logo in red at the center and a digital display on the right showing '26'.

Figur 2: Vinklet view of the Akai 12000BTU Split Air Conditioner indoor unit, showing its side profile and the air outlet louvers at the bottom. The AKAI logo and '26' display are visible.
Opsætning og installation
Installation of this split air conditioner requires specialized tools and knowledge. It is strongly recommended that installation be performed by a certified technician to ensure proper function and safety.
Kontrol før installation:
- Bekræft strømforsyningen voltage and circuit breaker capacity.
- Ensure the installation location for both indoor and outdoor units allows for proper airflow and drainage.
- Check for structural integrity of the wall where the indoor unit will be mounted.
Installationstrin (Overview for Technician):
- Mount the indoor unit plate on the wall.
- Drill a hole for the refrigerant piping and drain hose.
- Connect refrigerant pipes and electrical wiring between indoor and outdoor units.
- Secure the outdoor unit on a stable base.
- Perform vacuuming and refrigerant charging.
- Check for leaks and test operation.
Warning: Improper installation can lead to electric shock, fire, water leakage, and other hazards. Do not attempt self-installation.
Betjeningsvejledning
Your Akai air conditioner can be operated using the supplied wireless remote control.
Fjernbetjeningsfunktioner:
- Power knap: Tænder/slukker enheden.
- Mode knap: Cycles through modes: Cool, Dry, Fan, Heat (if applicable), Auto.
- Temperaturknapper (▲/▼): Justerer den ønskede temperatur.
- Ventilatorhastighedsknap: Vælger ventilatorhastighed (Auto, Lav, Mellem, Høj).
- Sving knap: Styrer den vertikale lamelbevægelse.
- Timer knap: Sets ON/OFF timer.
- Sove mode: Justerer temperaturen for en behagelig søvn.
Grundlæggende betjening:
- Tryk på Power-knappen for at tænde enheden.
- Press the Mode button to select your desired operating mode (e.g., Cool).
- Use the Temperature buttons to set the desired room temperature.
- Juster ventilatorhastigheden efter behov.
For optimal performance, keep doors and windows closed while the air conditioner is operating.
Vedligeholdelse og pleje
Regelmæssig vedligeholdelse sikrer effektiv drift og forlænger levetiden på dit klimaanlæg.
Rengøring af luftfilteret:
The anti-dust filter should be cleaned every two weeks or more frequently depending on usage and air quality.
- Turn off the air conditioner and disconnect power.
- Åbn frontpanelet på indendørsenheden.
- Fjern luftfiltrene.
- Rengør filtrene med en støvsuger, eller vask dem med lunkent vand og et mildt rengøringsmiddel.
- Rinse thoroughly and allow to dry completely in a shaded area before reinstalling.
- Reinstall the filters and close the front panel.
Cleaning the Indoor Unit:
Wipe the indoor unit with a soft, dry cloth. For stubborn dirt, use a damp cloth with a mild detergent, then wipe dry. Do not use harsh chemicals, abrasives, or hot water.
Vedligeholdelse af udendørsenhed:
The outdoor unit should be inspected and cleaned periodically by a qualified technician to remove debris from the condenser coils and ensure proper drainage.
Caution: Never attempt to clean the internal components of the air conditioner without professional assistance. Risk of electric shock.
Fejlfinding Guide
Før du kontakter service, skal du se på følgende almindelige problemer og løsninger:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden starter ikke | Ingen strøm, afbryderen er udløst, og fjernbetjeningens batterier er døde. | Check power supply, reset breaker, replace remote batteries. |
| Utilstrækkelig køling | Dirty air filter, blocked outdoor unit, doors/windows open, temperature setting too high. | Clean air filter, clear obstructions from outdoor unit, close doors/windows, lower temperature setting. |
| Vandlækage fra indendørsenhed | Tilstoppet afløbsslange, forkert installation. | Check and clear drain hose. If issue persists, contact service. |
| Usædvanlig støj | Loose parts, foreign object in fan, compressor noise (normal during startup/shutdown). | If persistent or loud, turn off unit and contact service. |
Hvis problemet fortsætter efter at have forsøgt disse løsninger, bedes du kontakte kvalificeret servicepersonale.
Produktspecifikationer
| Feature | Specifikation |
|---|---|
| Mærke | AKAI |
| Modelnummer | ACMA-A12T3N |
| Kølekapacitet | 12000 BTU (1 Ton) |
| Kompressor type | T3 Rotary Compressor |
| Voltage | 230 volt |
| Wattage | 3700 watt |
| Støjniveau (indendørs) | 55 decibel |
| Produktmål (indendørsenhed) | 79 x 19.9 x 27 cm |
| Varens vægt | 24 kilo |
| Særlige funktioner | Anti-dust filter, Humidity control, Energy-efficient design |
Garantioplysninger
This Akai air conditioner comes with a minimum 1-year manufacturer warranty. Please refer to the warranty card included with your product for specific terms, conditions, and registration details. Keep your purchase receipt as proof of purchase for warranty claims.
The warranty typically covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, neglect, unauthorized repairs, or acts of nature.
Kundesupport
For technical assistance, service requests, or inquiries regarding your Akai 12000BTU Split Air Conditioner, please contact Akai customer support.
Contact details can typically be found on the Akai official webwebstedet eller på garantikortet, der fulgte med dit produkt.
When contacting support, please have your model number (ACMA-A12T3N) and purchase date readily available.