ACR PLB-410 RLS

ACR ResQLink 410 RLS Personal Locator Beacon User Manual

Indledning

The ACR ResQLink 410 RLS is a compact, buoyant personal locator beacon designed to alert search and rescue services in emergency situations. It features Return Link Service (RLS), GPS, Galileo GNSS, and MEOSAR compatibility for global coverage and accurate positioning. This manual provides essential information for the proper setup, operation, and maintenance of your ResQLink 410 RLS.

ACR ResQLink 410 RLS Personal Locator Beacon
The ACR ResQLink 410 RLS Personal Locator Beacon, a compact device for emergency signaling.

Produkt overview Video

Denne video giver en overview of the new ACR ResQLink RLS Personal Locator Beacons, highlighting their key features and benefits.

Opsætning

Registrering

Before initial use, it is mandatory to register your ACR ResQLink 410 RLS with the appropriate national authority (e.g., NOAA in the USA). Registration ensures that search and rescue services have access to your emergency contact information and vessel details, which is crucial for a timely and effective rescue. Failure to register may delay rescue efforts. Follow the instructions provided in the packaging or visit the manufacturer's website for detailed registration steps.

Batteriinstallation/-kontrol

The ResQLink 410 RLS comes with two Lithium Metal batteries pre-installed. These batteries have a 5-year life. Regularly check the battery expiration date printed on the device. If the battery is nearing its expiration or has been activated, it must be replaced by an authorized service center to ensure proper functionality.

Initial Activation Test

It is recommended to perform a self-test upon receiving your beacon and periodically thereafter to ensure it is functioning correctly. Refer to the 'Self-Test Function' in the Operating Instructions section for detailed steps.

Activation Guide Video

This video demonstrates the activation process for ACR ResQlink 400 and 425 series PLBs, which is similar to the 410 RLS model.

Betjeningsvejledning

Nødaktivering

  1. Udplacering af antenne: Slide the antenna cover to expose and fully extend the antenna. Ensure it is positioned at a 90-degree angle to the device, pointing towards the sky.
  2. Activate Beacon: Press and hold the 'ON' button for approximately 2 seconds until the red LED light begins to flash and the strobe light activates. The device will immediately begin to acquire GPS coordinates.
  3. Confirm RLS: Once GPS is acquired, the red LED light will turn green, indicating that your distress message has been sent and Return Link Service (RLS) confirmation is being processed.
  4. Bevar stilling: Keep the beacon in an open area with a clear view of the sky until rescue personnel arrive. Do not turn it off until you have been rescued.
ACR ResQLink 410 RLS in hand
The ACR ResQLink 410 RLS held in hand, ready for deployment.

Deaktivering

To deactivate the beacon, press and hold the power button for 3 seconds. The device will power off. Once deactivated, retract the antenna and secure the cover.

Selvtest funktion

The self-test function allows you to verify the beacon's operational status without sending a distress signal. To perform a self-test, ensure the antenna is deployed, then press the 'TEST' button (often indicated by a 'T' or checkmark) for 1 second. The display will show 'TEST' and then 'GPS' as it attempts to acquire a signal. A successful test will typically show 'PASS' or a green light, indicating the beacon is ready for use.

Opretholdelse

To ensure your ResQLink 410 RLS remains in optimal working condition, perform regular checks:

Fejlfinding

No GPS Signal Acquisition

Sørg for, at fyret har en klar og uhindret bane view of the sky. Obstructions like dense foliage, buildings, or being inside a vessel can prevent GPS signal acquisition. Move to an open area if possible.

Beacon Not Activating

Verify that the antenna is fully deployed and the activation button is pressed and held for the specified duration (typically 2 seconds for activation). Check the battery status if the device fails to respond.

Falske alarmer

If the beacon is accidentally activated, immediately deactivate it by pressing and holding the power button for 3 seconds. Contact your national search and rescue authority (e.g., NOAA) to report the false alarm and prevent unnecessary deployment of resources.

Specifikationer

FeatureDetalje
Produktdimensioner4.52 x 2.03 x 1.49 tommer
Varens vægt1 pund
VaremodelnummerPLB-410 RLS
Batterier2 Lithium Metal batterier påkrævet (medfølger)
ForbindelsesteknologierRF
GPSGPS aktiveret
Særlige funktionerReturn Link Service
Human Interface InputKnapper
FarveSort, Gul
Hvad er der i æskenBelt Clip, PFD Oral Inflation Tube Clip, Attachment Strap
FabrikantACR elektronik
Dato først tilgængelig14. juni 2022

Garantioplysninger

The ACR ResQLink 410 RLS typically comes with a manufacturer's warranty. For specific details regarding warranty coverage, duration, and claims procedures, please refer to the official warranty documentation included with your product or visit the ACR Electronics webwebsted. Gem din købsbevis af garantihensyn.

Support og kontakt

For technical assistance, product inquiries, or to report an emergency beacon activation, please contact ACR Electronics customer support. You can find contact information on the official ACR Electronics webwebsted.

ACR Electronics Official Webwebsted: www.acrartex.com

Relaterede dokumenter - PLB-410 RLS

Preview ACR ResQLink PLB installationsvejledning til Atlas 190 UML redningsvest
Trinvise instruktioner til montering af en ACR ResQLink personlig lokaliseringssignal (PLB) på en Atlas 190 UML redningsvest, der sikrer sikker og korrekt funktionalitet.
Preview ACR ResQlink AIS monteringsvejledning til Atlas 190 Hammar redningsvest
Trin-for-trin-guide til montering af en ACR ResQlink AIS personlig lokaliseringssignal (PLB) på en Mustang Survival Atlas 190 Hammar redningsvest, der sikrer korrekt og sikker installation i nødsituationer.
Preview Instruktioner til ACR AISLink MOB til ELITE 190 oppustelig redningsvest
Trin-for-trin-guide til, hvordan man monterer en ACR AISLink MOB-enhed på en ELITE 190 oppustelig redningsvest, hvilket sikrer sikker og korrekt funktion.
Preview ACR Kelowna gaskomfurmanual: Installation, drift og vedligeholdelse
Omfattende bruger- og installationsmanual til ACR Kelowna gaskomfur (model 12H, G20 ved 20 mbar), der dækker opsætning, betjening, tekniske specifikationer, rengøring, vedligeholdelse, fejlfinding, fejlkoder og garantioplysninger.
Preview Monterings- og installationsvejledning til ACR RCL-300A søgelys
Omfattende vejledning til montering og installation af ACR RCL-300A søgelyssystemet, inklusive URC-300 mastercontroller og URC-102 punktpude, med detaljerede ledningsføringsinstruktioner og funktioner.
Preview ACR Electric SEREN Komfur Installations- og Brugermanual
Omfattende installations- og brugermanual til ACR Electric SEREN komfurserien (SEREN-70, SEREN-130, SEREN-150), der dækker opsætning, betjening, vedligeholdelse, fejlfinding og garantioplysninger.