1. Introduktion
Thank you for choosing the Mirage Life 12+ Mini Split Air Conditioner. This manual provides comprehensive instructions for the safe and efficient installation, operation, and maintenance of your new unit. Please read this manual thoroughly before using the appliance and keep it for future reference. Proper use and care will ensure optimal performance and longevity of your air conditioner.
2. Sikkerhedsoplysninger
Your safety and the safety of others are very important. Please read and follow all safety messages outlined in this manual to prevent serious injury or property damage. Always adhere to local electrical codes and regulations.
Generelle forholdsregler:
- Only qualified personnel should perform installation, repair, or maintenance. Improper installation can result in electric shock, fire, or water leakage.
- Ensure the power supply matches the unit's specifications (110V). Do not use extension cords or multi-outlet adapters.
- Stik ikke fingre eller genstande ind i luftindtaget/-udtaget.
- Betjen ikke enheden med våde hænder.
- Hold brændbare materialer væk fra enheden.
- If the unit emits smoke or an unusual smell, immediately turn off the power and contact a service technician.
3. Produktet er slutview
The Mirage Life 12+ is a 1-ton mini split air conditioner designed for efficient cooling and heating. It consists of an indoor unit, an outdoor unit, and a remote control for convenient operation.
Komponenter:
- Indendørs enhed: Mounted inside the room, responsible for air distribution.
- Udendørs enhed: Mounted outside, responsible for heat exchange.
- Fjernbetjening: Used to control the unit's functions and settings.

Figur 3.1: Forside view of the Mirage Life 12+ Mini Split indoor unit. This image shows the sleek white design of the indoor air handler, featuring the 'Mirage' logo on the left and 'LIFE 12+' branding on the right.

Figur 3.2: Vinklet view of the Mirage Life 12+ Mini Split indoor unit. This perspective highlights the depth and side profile of the indoor unit, providing a better understanding of its physical form.

Figure 3.3: Remote control for the Mirage Life 12+ Mini Split. The remote features a digital display at the top showing the set temperature, and various buttons for functions like ON/OFF, Mode, Temp, Fan Speed, Swing, Timer, Sleep, Turbo, and Display.

Figure 3.4: Dimensions of the Mirage Life 12+ Mini Split indoor unit. This image illustrates the unit's measurements: 171cm in length, 59cm in depth, and 92cm in height.
4. Opsætning og installation
Installation should only be performed by a qualified and certified HVAC technician. Incorrect installation can lead to serious issues, including electric shock, fire, and water leakage.
4.1 Tjekliste før installation:
- Beliggenhed: Choose a location for the indoor unit that allows for even air distribution and easy drainage. The outdoor unit should be placed in a well-ventilated area, away from direct sunlight and obstructions.
- Strømforsyning: Ensure a dedicated 110V power circuit is available for the unit.
- Værktøjer: Gather all necessary tools, including drills, wrenches, vacuum pump, manifold gauge, and safety equipment.
4.2 Installation af indendørsenhed:
- Montering af monteringsplade: Securely fasten the mounting plate to the wall, ensuring it is level and can support the unit's weight.
- Bor væghul: Drill a hole (typically 65mm-75mm diameter) through the wall for the refrigerant piping and drainage hose.
- Kølemiddelrørtilslutning: Connect the refrigerant pipes (liquid and gas lines) to the indoor unit. Ensure connections are tight to prevent leaks.
- Drainage Hose Connection: Connect the drainage hose, ensuring it slopes downwards to allow for proper water flow.
- Elektriske ledninger: Connect the electrical wires according to the wiring diagram provided with the unit.
- Monter indendørsenhed: Carefully mount the indoor unit onto the mounting plate.
4.3 Installation af udendørsenhed:
- Placering og montering: Place the outdoor unit on a stable, level surface or a dedicated mounting bracket. Ensure adequate clearance for airflow.
- Kølemiddelrørtilslutning: Connect the refrigerant pipes from the indoor unit to the outdoor unit.
- Vacuuming and Charging: Evacuate the refrigerant lines using a vacuum pump to remove air and moisture. If necessary, charge the system with the correct amount of R-32 refrigerant.
- Elektriske forbindelser: Connect the power supply and communication wires to the outdoor unit as per the wiring diagram.
4.4 Elektriske forbindelser:
The Mirage Life 12+ operates on 110 Volts. All electrical wiring must comply with national and local electrical codes. Ensure the circuit breaker is off before making any electrical connections. Use appropriate gauge wiring for the power supply.
5. Betjeningsvejledning
Your Mirage Life 12+ Mini Split is controlled via the wireless remote control. Familiarize yourself with the remote's functions for optimal use.
5.1 Fjernbetjeningsfunktioner:
- ON/OFF knap: Tryk for at tænde eller slukke for enheden.
- MODE knap: Skifter mellem driftstilstande: Auto, Køling, Tørring, Ventilator, Varme.
- TEMP +/- knapper: Justerer den ønskede temperaturindstilling.
- FAN SPEED knap: Selects fan speed: Auto, Low, Medium, High.
- SWING knap: Styrer den lodrette luftstrømsretning (lamellernes udsving).
- TIMER TIL/FRA-knapper: Sets the time for the unit to automatically turn on or off.
- SLEEP knap: Aktiverer dvaletilstand for stille drift og energibesparelse under søvn.
- TURBO knap: Activates rapid cooling or heating for quick temperature adjustment.
- DISPLAY-knap: Turns the indoor unit's display light on or off.
5.2 driftstilstande:
- Cool tilstand: Til afkøling af rummet. Indstil den ønskede temperatur.
- Varmetilstand: Til opvarmning af rummet. Indstil den ønskede temperatur.
- Tør tilstand: Reducerer luftfugtigheden i rummet.
- Ventilatortilstand: Cirkulerer luft uden afkøling eller opvarmning.
- Automatisk tilstand: The unit automatically selects the operating mode (Cool, Heat, Fan) based on the room temperature and your set temperature.
5.3 Setting Temperature:
Tryk på TEMP + or TEMP - buttons on the remote control to increase or decrease the desired temperature. The temperature range is typically between 16°C and 30°C (60°F and 86°F).
5.4 Timerfunktion:
To set the timer for automatic ON/OFF, press the TIMER TIL or TIMER FRA knap. Brug TEMP +/- buttons to adjust the desired time, then press the timer button again to confirm.
6. Vedligeholdelse
Regular maintenance ensures the efficient and long-lasting operation of your Mirage Life 12+ Mini Split. Always turn off the power supply to the unit before performing any maintenance.
6.1 Regelmæssig rengøring:
- Luftfiltre: Clean the air filters every two weeks or more frequently if the unit is used heavily or in dusty environments. Remove the filters, wash them with lukewarm water and mild detergent, rinse thoroughly, and allow them to dry completely before reinserting.
- Indoor Unit Surface: Wipe the indoor unit's surface with a soft, dry cloth. For stubborn dirt, use a damp cloth with mild detergent, then wipe dry. Do not use harsh chemicals or abrasive cleaners.
- Udendørs enhed: Periodically clear any debris (leaves, dirt) from around the outdoor unit. Ensure the coils are free from obstructions. For thorough cleaning of outdoor coils, it is recommended to contact a professional.
6.2 Seasonal Maintenance:
- Før sommer/vinter: Få en kvalificeret tekniker til at inspicere kølemiddelniveauer, elektriske forbindelser og systemets samlede ydeevne.
- Afløbskontrol: Ensure the drainage hose is not clogged and water can flow freely.
7. Fejlfinding
Før du kontakter kundesupport, bedes du se følgende tabel for almindelige problemer og løsninger på disse.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | No power supply; Circuit breaker tripped; Remote control batteries dead. | Check power connection; Reset circuit breaker; Replace remote control batteries. |
| Utilstrækkelig køling/opvarmning. | Snavsede luftfiltre; Tilstoppet udendørsenhed; Forkert indstilling af tilstand; Lavt kølemiddelniveau. | Rengør luftfiltre; Fjern blokeringer fra udendørsenheden; Vælg korrekt tilstand; Kontakt en tekniker for kølemiddelkontrol. |
| Usædvanlig støj. | Loose parts; Fan obstruction; Compressor issue. | Check for loose parts; Remove any obstructions; Contact technician. |
| Vandlækage fra indendørsenheden. | Clogged drainage hose; Improper installation. | Clear drainage hose; Contact technician for re-installation check. |
| Fjernbetjening virker ikke. | Dead batteries; Obstruction between remote and unit; Remote out of range. | Replace batteries; Remove obstructions; Operate within range. |
8. Tekniske specifikationer
| Feature | Værdi |
|---|---|
| Mærke | Mirage |
| Modelnummer | 2 (MMI12HABWCATME1/MMI12HABWCATMI1) |
| Farve | Hvid |
| Produktdimensioner | 59 x 171 x 92 cm |
| Kapacitet | 1 ton |
| Strøm/Wattage | 110 |
| Voltage | 110 volt |
| Støjniveau | 60 dB |
| Særlige funktioner | Hurtig afkøling |
| Varens vægt | 40 kg |
| Kølemiddel | R-32 |
| Strømkilde | El-kabel |
| Garantitype | Livstid |
9. Garanti og kundesupport
The Mirage Life 12+ Mini Split Air Conditioner comes with a Livstidsgaranti, as specified by the manufacturer. Please retain your proof of purchase for warranty claims.
For technical assistance, troubleshooting beyond this manual, or warranty service, please contact Mirage customer support. Refer to the product packaging or the official Mirage webhjemmeside for de seneste kontaktoplysninger.
Note: Unauthorized service or repairs may void your warranty.