1. Introduktion

This manual provides essential information for the proper installation, operation, and maintenance of your FireAngel FA6120 Optical Smoke Alarm. The FA6120 is designed for early detection of slow-burning fires, featuring an advanced optical sensor and a sealed 10-year battery for continuous protection. It serves as a direct replacement for older FireAngel ST-622/ST-620 models.

2. Produktet er slutview

The FireAngel FA6120 is a compact, optical smoke alarm engineered for reliable home fire safety. Its key features include:

  • Optisk sensor: Detects smoke from slow-burning fires, reducing false alarms from cooking fumes.
  • 10 års forseglet batteri: Provides continuous power for the entire lifespan of the alarm, eliminating the need for battery replacement.
  • Test/Stilhed knap: Allows for easy testing of the alarm's functionality and temporary silencing of nuisance alarms or low battery warnings.
  • Sleep Easy™ Function: Temporarily silences low battery warnings for 8 hours, ideal for nighttime alerts, while maintaining smoke detection capability.
FireAngel FA6120 Optical Smoke Alarm front view

Figur 1: Front view of the FireAngel FA6120 Optical Smoke Alarm, showing the central test/silence button and FireAngel branding.

3. Sikkerhedsoplysninger

Din sikkerhed er altafgørende. Følg venligst følgende retningslinjer:

  • The FA6120 smoke detector is CE marked and certified to EN 14604:2005+AC:2008 standards, and carries the Q-label, ensuring high safety and performance.
  • The integrated battery is sealed and non-replaceable. Do not attempt to open the unit or replace the battery.
  • Avoid placing the alarm near bathrooms or kitchens, as steam and cooking fumes can trigger nuisance alarms.
  • Regularly test your smoke alarm as described in the Operating Instructions section.

4. Opsætning og installation

The FireAngel FA6120 is designed for easy installation. Follow these steps to properly mount your smoke alarm:

  1. Vælg placering: Select a suitable location on the ceiling, ensuring it is at least 300 mm (12 inches) away from luminaires (light fixtures) and walls. Smoke alarms are suitable for habitable recreational vehicles. Do not install in kitchens or bathrooms due to potential nuisance alarms from steam or cooking fumes.
  2. Monter bundplade: Use the provided screws (not supplied with the alarm, typically standard mounting screws) to fix the removable base plate securely to the ceiling. The base plate is identical to that of the ST622 model, allowing for easy replacement.
  3. Tilslut alarm: Once the base plate is mounted, push the smoke alarm onto the base plate and turn it clockwise until it clicks firmly into place.
Installation steps for FireAngel FA6120 smoke alarm

Figur 2: Visual guide for installing the FireAngel FA6120, showing the removable base plate and the twist-on attachment method.

Placement guidelines for FireAngel smoke alarms

Figur 3: Illustration of recommended placement, indicating a minimum distance of 300mm from walls and light fixtures, suitability for RVs, and unsuitability for kitchens/bathrooms.

5. Betjeningsvejledning

Understanding how to operate your smoke alarm ensures its effectiveness.

5.1. Test af alarmen

To ensure your alarm is functioning correctly, press and hold the large central Test/Silence button. A loud alarm sound will confirm its proper operation. Test your alarm weekly.

5.2. Silencing Nuisance Alarms

In the event of a false alarm (e.g., from cooking fumes or steam), press the Test/Silence button to temporarily silence the alarm for 10 minutes. Ensure the cause of the false alarm is identified and resolved.

5.3. Sleep Easy™ Function

If a low battery alert sounds during the night, you can activate the Sleep Easy™ function. Press the Test/Silence button to silence the low battery chirp for 8 hours. The red LED will continue to flash, indicating the low battery status. The alarm will still detect smoke during this period. Remember to replace the alarm within 30 days of the first low battery alert, as the battery is sealed and non-replaceable.

6. Vedligeholdelse

Proper maintenance helps ensure the longevity and reliability of your smoke alarm.

  • Ugentlig test: Test your smoke alarm weekly by pressing the Test/Silence button.
  • Rensning: Gently vacuum the alarm's casing once a month using a soft brush attachment to remove dust and cobwebs. Do not use cleaning solvents or sprays.
  • Batteri: The alarm features a sealed 10-year lithium battery that does not require replacement. When the alarm reaches the end of its 10-year lifespan or consistently indicates a low battery, the entire unit must be replaced.

7. Fejlfinding

Se tabellen nedenfor for almindelige problemer og løsninger på disse:

ProblemMulig årsagLøsning
Alarmen lyder periodisk eller uden nogen åbenlys grund.Nuisance alarm from steam, cooking fumes, or dust.Press the Test/Silence button to silence for 10 minutes. Clean the alarm. Relocate if consistently triggered by environmental factors.
Alarm chirps periodically (e.g., every 30-60 seconds).Advarsel om lavt batteri.If at night, use Sleep Easy™ function. Replace the entire alarm unit within 30 days.
Alarmen lyder ikke, når der trykkes på testknappen.Alarm malfunction or end of life.Ensure the alarm is correctly mounted. If still unresponsive, replace the unit immediately.

8. Specifikationer

FeatureDetalje
ModelnummerFA6120-INT
MærkeIldEngel
SensortypeOptisk
StrømkildeSealed Lithium Battery (1 CR123A equivalent)
Batterilevetid10 Years (non-replaceable)
Alarmens lydniveau85 dB(A) ved 3 meter
Dimensioner (H x D)3.15 cm x 11.81 cm
Vægt138 gram
MaterialePlast
CertificeringerCE, EN 14604:2005+AC:2008, Q-label
Inkluderede komponenter1 x Baseplate, 1 x Instruction Manual, 1 x Optical Smoke Alarm with Sealed Lithium Battery

9. Garanti og support

The FireAngel FA6120 Optical Smoke Alarm comes with a 1-year availability for spare parts, as per EU regulations. For specific warranty details, technical support, or further assistance, please refer to the contact information provided in the packaging or visit the official FireAngel website. Always ensure you have your model number (FA6120-INT) ready when contacting support.

Relaterede dokumenter - FA6120-INT

Preview FireAngel Røg- og Varmealarm Brugermanual: FA6611, FA6615, FA6620, FA6720
Brugermanual til FireAngel optiske røgalarmer (FA6611, FA6615, FA6620) og varmealarmer (FA6720). Indeholder detaljerede oplysninger om placering, installation, vedligeholdelse, fejlfinding, lydløshed og "sleep easy"-funktioner, garanti og bortskaffelsesinstruktioner for at sikre brandsikkerhed i hjemmet.
Preview FireAngel ST-625-INT Røgalarm Brugermanual
Omfattende brugermanual til FireAngel ST-625-INT røgalarmen, der dækker installation, funktioner, vedligeholdelse og garanti. Denne vejledning indeholder vigtige sikkerhedsoplysninger og betjeningsinstruktioner.
Preview FireAngel ST-622-BNLT Optisk Røgdetektor - 10 års batteri
Detaljerede specifikationer og produktbeskrivelse for den optiske røgdetektor FireAngel ST-622-BNLT. Har 10 års batterilevetid, Thermoptek-teknologi, Smart Silence og et insektbestandigt kammer. Lær om dens tekniske detaljer og fordele.tages.
Preview FireAngel Røg- og Varmealarm Brugermanual: FA6611, FA6615, FA6620, FA6720
Omfattende brugermanual til FireAngel FA6611, FA6615, FA6620 optiske røgalarmer og FA6720 varmealarm. Dækker installation, vedligeholdelse, fejlfinding, garanti og bortskaffelse.
Preview FireAngel WST-630N Trådløs Interlink Røgalarm Brugermanual
Omfattende brugermanual til den trådløse FireAngel WST-630N røgalarm. Lær om Thermoptek-teknologi, installation, betjening og sikkerhedsfunktioner til pålidelig branddetektering i hjemmet.
Preview FireAngel SCB10 Kombination af røg- og kuliltealarm brugermanual
Brugermanual til FireAngel SCB10, en kombineret røg- og kuliltealarm, der indeholder omfattende instruktioner om installation, betjening, vedligeholdelse og sikkerhed til brug i private hjem.