MAXWELL 2MX18AXVJU+CTX09AXVJU+CTX09AXVJU

Daikin 2-Zone CIRRA Series Mini Split Air Conditioner Heat Pump System

Model: 2MX18AXVJU+CTX09AXVJU+CTX09AXVJU

Mærke: MAXWELL

1. Produktet er slutview

The Daikin 2-Zone CIRRA Series Mini Split Air Conditioner Heat Pump System is designed for multi-room applications, providing individual comfort in a space-saving design. This system allows connection of two wall-mounted indoor units to a single outdoor unit, offering a compact and efficient solution for various spaces. It features advanced technologies for enhanced performance and durability.

Daikin 2-Zone Mini Split System Components

Figure 1.1: Complete Daikin 2-Zone Mini Split System, showing two indoor units, one outdoor condenser, two remote controls, two pre-flared line sets, two communication cables, and a wall mounting bracket kit.

Nøglefunktioner:

Daikin 2-Zone System Components Diagram

Figure 1.2: Diagram illustrating the main components included in your system: two wall-mount indoor units, two remote controls, two pre-flared line sets, two communication cables, an outdoor unit bracket, and an R410A pre-charged outdoor condenser.

2. Opsætning og installation

Proper installation is crucial for optimal performance and longevity of your Daikin Mini Split System. It is highly recommended that installation be performed by a qualified HVAC professional.

Komponenter inkluderet:

Maxwell 15 ft. Installation Kit

Figure 2.1: The Maxwell 15 ft. installation kit, which includes pre-flared refrigerant lines and electrical communication cables, essential for connecting the indoor and outdoor units.

Wall Mounting Bracket for Outdoor Unit

Figure 2.2: The robust wall mounting bracket and associated hardware, designed to securely support the outdoor condenser unit.

Installation Steps (Summary - Refer to full installation manual for detailed instructions):

  1. Vælg placering: Choose appropriate locations for indoor units (wall-mounted) and the outdoor condenser, ensuring proper airflow and drainage.
  2. Mount Indoor Units: Securely attach the mounting plates to the wall and install the indoor units.
  3. Install Outdoor Condenser: Mount the outdoor unit using the provided wall bracket or a suitable ground-level pad.
  4. Tilslut kølemiddelledninger: Carefully connect the pre-flared refrigerant lines between the indoor and outdoor units. Ensure proper torque to prevent leaks.
  5. Elektriske ledninger: Connect the communication cables and power supply according to local electrical codes and the wiring diagram in the detailed manual.
  6. Vakuum og opladning: Evacuate the refrigerant lines to remove air and moisture. The system comes pre-charged, but additional refrigerant may be needed depending on line length.
  7. Test drift: Power on the system and test all modes (cooling, heating, fan) to ensure correct operation.

3. Betjeningsvejledning

Your Daikin Mini Split System is controlled via the included wireless remote controls, one for each indoor unit. Familiarize yourself with the remote's functions for optimal comfort.

Daikin Mini Split fjernbetjening

Figure 3.1: The wireless remote control for the Daikin Mini Split indoor unit, featuring buttons for power, temperature adjustment, mode selection (Cool, Heat, Fan), and special functions like Eco+ and Sleep.

Grundlæggende betjening:

Avancerede funktioner:

4. Vedligeholdelse

Regular maintenance ensures efficient and reliable operation of your Daikin Mini Split System. Always disconnect power before performing any maintenance.

Vedligeholdelse af indendørsenhed:

Vedligeholdelse af udendørsenhed:

5. Fejlfinding

This section provides solutions for common issues. For complex problems, contact a qualified technician.

ProblemMulig årsagLøsning
Enheden tænder ikkeIngen strøm; Fjernbetjeningens batterier er lave; Afbryderen er udløst.Kontroller strømforsyningen; Udskift fjernbetjeningens batterier; Nulstil afbryderen.
Utilstrækkelig køling/opvarmningDirty air filters; Blocked outdoor unit; Low refrigerant; Incorrect mode setting.Clean filters; Clear obstructions; Contact technician for refrigerant check; Verify mode.
Usædvanlig støjLøse dele; Blokering af ventilator; Støj fra kølemiddelflow (normalt).Check for loose parts; Remove obstructions; If noise persists, contact technician.
Vandlækage fra indendørsenhedTilstoppet afløbsledning; Forkert installation.Rengør afløbsledningen; kontakt en fagmand for inspektion.

6. Specifikationer

Detailed technical specifications for the Daikin 2-Zone CIRRA Series Mini Split System.

Daikin Dual-Zone System Specification Diagram

Figure 6.1: Detailed diagram showing dimensions of both indoor and outdoor units, along with key specifications such as power supply, operating ranges, rated capacity, piping connections, refrigerant type, and pre-charged piping length.

SpecifikationVærdi
MærkenavnMAXWELL
Model info2MX18AXVJU+CTX09AXVJU+CTX09AXVJU
Varens vægt145 pund
Produktdimensioner9 x 31 x 11 cm (indendørs enhed)
Effektivitet (SEER)17.0
Kapacitet1.5 Tons (Total)
Støjniveau51 dB (Outdoor)
InstallationstypeOpdelt system
Særlige funktionerAnti-Corrosion Treatment, Automatic Defrosting, Eco+ Mode, Quick Warming Function
Voltage230 volt
Wattage5125 watt
Dækning af gulvareal800 kvadratmeter
Driftskølingsområde50° - 115°F
Driftsvarmeområde5° - 65°F
Sæsonbestemt varmeydelsesfaktor (HSPF)9.00
Energy Guide Label for Daikin 2MX18AXVJU

Figure 6.2: The official Energy Guide label for the Daikin 2MX18AXVJU model, indicating a Cooling Efficiency Rating (SEER) of 17.00 and a Heating Efficiency Rating (HSPF) of 9.00.

7. Garanti og support

Garantioplysninger:

This Daikin Mini Split System comes with a 10-Year Daikin Manufacturer Warranty. Please retain your proof of purchase for warranty claims. For specific warranty terms and conditions, refer to the documentation provided with your product or contact Daikin customer service.

Kundesupport:

For technical assistance, troubleshooting beyond this manual, or warranty service, please contact MAXWELL customer support. You can typically find contact information on the product packaging, the official MAXWELL webwebstedet eller gennem dit købssted.

When contacting support, please have your product model number (2MX18AXVJU+CTX09AXVJU+CTX09AXVJU) and serial number ready to expedite the process.

Relaterede dokumenter - 2MX18AXVJU+CTX09AXVJU+CTX09AXVJU

Preview Maxwell WAFR24 beslag monteringsvejledning
Detaljeret installationsvejledning til Maxwell WAFR24 justerbart tagmonteret beslag, inklusive en liste over tilbehør og trinvise monteringsvejledninger.
Preview RC12-HD Vertikalt ankerspil - Installations-, drifts- og vedligeholdelsesmanual
Omfattende manual til Maxwell RC12-HD vertikalt ankerspil, der dækker installation, betjening, vedligeholdelse, specifikationer, fejlfinding og reservedele. Indeholder detaljerede diagrammer og ledningsdiagrammer.
Preview CFT 100 Digital Timer and Counter (2-in-1) User Manual
User manual for the CFT 100 digital timer and counter, covering features, panel description, ordering information, dimensions, wiring, parameter settings, and RS-485 communication protocols.
Preview Maxwell 25700 Automatisk Digitalt Multimeter Brugermanual
Brugermanual til Maxwell 25700 automatisk digitalt multimeter med berøringsfri voluminiumsmålingtage-detektion, omfattende målefunktioner og sikkerhedsretningslinjer.
Preview Maxwell MW-1441 W ismaskine - Brugermanual og instruktioner
Officiel brugermanual og instruktioner til Maxwell MW-1441 W ismaskine. Lær, hvordan du samler, bruger, rengør og foretager fejlfinding på dit apparat. Indeholder opskrifter og tekniske specifikationer.
Preview MAXWELL MX 25 313 ​​digitalt multimeter brugermanual
Omfattende brugermanual til MAXWELL MX 25 313 ​​digitalt multimeter, der dækker funktioner, tekniske specifikationer, sikkerhedsoplysninger og betjeningsinstruktioner for nøjagtig volumenmåling.tage, strøm, modstand og flere målinger.