SITERWELL GS886F

SITERWELL Hardwired Interconnected Smoke and Carbon Monoxide Detector Combo

Model: GS886F

1. Introduktion

This manual provides essential information for the proper installation, operation, and maintenance of your SITERWELL Hardwired Interconnected Smoke and Carbon Monoxide Detector Combo. This device is designed to provide early warning of both smoke and carbon monoxide hazards in residential environments. Please read this manual thoroughly before installation and retain it for future reference.

SITERWELL Interconnected Combination Smoke and Carbon Monoxide Detector with key features highlighted.

Billede 1: Overview of the SITERWELL Interconnected Combination Smoke and Carbon Monoxide Detector, highlighting its features such as wireless or hardwired interconnection, 2 AA battery backup, audible alarm, self-check function, low battery warning, and 2-in-1 sensor.

2. Vigtige sikkerhedsoplysninger

SITERWELL Smoke and Carbon Monoxide Detector installed on a ceiling with UL Certified logos.

Image 2: A SITERWELL detector mounted on a ceiling, with UL Certified and UL Listed marks, indicating compliance with safety standards.

3. Pakkens indhold

Bekræft at alle varer er til stede i din pakke:

Three SITERWELL Hardwired Interconnected Smoke and Carbon Monoxide Detector Combo units.

Image 3: Three SITERWELL Hardwired Interconnected Smoke and Carbon Monoxide Detector Combo units, showing their design and wiring.

4. Produktfunktioner

4.1. 2-in-1 Protection with Unique Voice Alert

This device integrates both smoke and carbon monoxide detection into a single unit. It provides an audible warning exceeding 85 decibels. The unique voice alert feature distinguishes between smoke and carbon monoxide hazards, announcing either "Fire!" (with 3 long beeps) or "Warning, Carbon Monoxide, Evacuate" (with 4 quick beeps), enabling a more organized response to emergencies.

SITERWELL detector on a ceiling with voice alert bubbles indicating 'Fire!' and 'Warning, Carbon Monoxide, Evacuate'.

Image 4: A SITERWELL detector installed on a ceiling, illustrating its 2-in-1 sensor and unique voice alert capabilities for both fire and carbon monoxide.

4.2. Hardwired and Wireless Interconnection

The detector supports both hardwired and wireless interconnection with up to 12 compatible units. When one alarm is triggered, all interconnected alarms will sound, ensuring everyone in the building is notified of the emergency. This feature is crucial for comprehensive safety coverage across larger homes or multiple floors.

Diagram showing multiple SITERWELL detectors interconnected across a floor plan, indicating a 328ft range.

Image 5: A floor plan illustrating how multiple SITERWELL detectors can be interconnected, covering an area of up to 328 feet, ensuring all units alarm simultaneously.

4.3. AC Power with 2 AA Battery Backup

The detector operates primarily on 120V AC power. It is equipped with a 2 AA battery backup system to ensure continuous operation during power outages, maintaining your safety even when the main power supply is interrupted.

Top image shows a detector connected to AC wiring, bottom image shows the battery compartment with two AA batteries.

Image 6: The top panel shows the detector connected via AC wiring, while the bottom panel displays the battery compartment with two AA batteries, illustrating the dual power source.

4.4. Self-Check Function

This SITERWELL detector includes a self-check feature that automatically monitors its operational status. If the detector experiences a malfunction, it will notify you promptly, eliminating the need for frequent manual testing to confirm functionality.

A SITERWELL detector with a green indicator light, signifying the self-check function is active, with a couple in a kitchen.

Image 7: The self-check function is indicated by a green light on the detector, ensuring it is working correctly without manual intervention.

4.5. 10-Year Sensor Life

The detector is equipped with a high-quality sensor designed for a 10-year operational life, providing long-term, uninterrupted protection.

eksploderede view of the SITERWELL detector showing internal components and a '10-Year' label on the sensor.

Billede 8: En eksploderet view of the detector highlights its internal components, emphasizing the 10-year sensor life for extended protection.

4.6. Kompakt design

The detector features a compact design, measuring 6.1 inches (155 mm) in diameter and 1.6 inches (41.8 mm) in thickness, allowing for discreet installation.

SITERWELL detector shown with dimensions: 6.1 inches (155 mm) diameter and 1.6 inches (41.8 mm) thickness.

Image 9: The compact design of the SITERWELL detector is shown with its dimensions, indicating a diameter of 6.1 inches (155 mm) and a thickness of 1.6 inches (41.8 mm).

5. Opsætning og installation

5.1. Valg af placering

Install detectors on every level of your home, including basements and attics, and inside every sleeping area. For optimal smoke detection, mount on the ceiling or high on a wall, at least 4 inches (10 cm) from any wall or ceiling intersection. For carbon monoxide detection, place the unit at a height where it can be heard by sleeping occupants, typically within 5 feet (1.5 meters) of the floor.

Diagram showing recommended placement of detectors in a living room, garage, and hallway.

Image 10: Recommended placement of detectors in various rooms such as the living room, garage, and hallway for optimal coverage.

5.2. Montering af detektoren

  1. Twist the mounting bracket counter-clockwise to detach it from the detector unit.
  2. Position the mounting bracket on the ceiling or wall at your chosen location. Mark the screw holes.
  3. Bor forhuller og isæt vægankre om nødvendigt.
  4. Fastgør monteringsbeslaget med de medfølgende skruer.

5.3. Wiring (Hardwired Connection)

ADVARSEL: Turn off power at the circuit breaker before wiring. Improper wiring can cause electric shock or fire.

5.4. Batteriinstallation

Open the battery compartment on the back of the detector. Insert two AA batteries, ensuring correct polarity (+ and -). Close the battery compartment securely.

5.5. Attaching the Detector

Align the detector with the mounting bracket and twist clockwise until it locks into place. Restore power at the circuit breaker.

Diagram showing the components of the SITERWELL detector including LED indicator, buzzer, fire retardant material, test/silence button, sounder, and air vents.

Image 11: Labeled components of the SITERWELL detector, including the LED indicator, buzzer, fire retardant materials, test/silence button, sounder, and air vents.

6. Betjeningsvejledning

6.1. Power-Up

Upon initial power-up (AC power and batteries installed), the detector will perform a self-test. The LED indicator will flash, and the unit may emit a short chirp or voice prompt.

6.2. LED-indikatorstatus

The 3-color LED indicator provides visual status:

SITERWELL detector with a 3-color LED indicator showing Alarm (Red), Low Battery (Yellow), and Normal (Green) states.

Image 12: The 3-color LED indicator on the SITERWELL detector, illustrating its different states: Red for Alarm, Yellow for Low Battery, and Green for Normal operation.

6.3. Test af detektoren

Tryk og hold på Test/Stilhed button for a few seconds. The alarm will sound, and the voice alert will announce its function (e.g., "Fire!" or "Warning, Carbon Monoxide, Evacuate"). This confirms the unit is functioning correctly. Test weekly.

6.4. Silence Feature

In case of a nuisance alarm (e.g., from cooking smoke), press the Test/Stilhed button to temporarily silence the alarm for approximately 10 minutes. The detector will automatically reset after this period if the hazard has cleared. If the hazard persists, the alarm will reactivate.

7. Vedligeholdelse

7.1. Regelmæssig rengøring

Clean your detector at least once a month. Use a soft brush attachment on your vacuum cleaner to remove dust and debris from the vents. Do not use cleaning solvents or spray directly onto the unit.

7.2. Udskiftning af batteri

When the detector indicates a low battery (yellow LED and/or chirping), replace both AA batteries immediately. Use only specified AA alkaline batteries. Refer to section 5.4 for battery installation steps.

7.3. End-of-Life Indication

After approximately 10 years of operation, the detector will indicate its end-of-life with a specific chirp pattern or voice message. Replace the unit immediately when this occurs to ensure continued protection.

8. Fejlfinding

ProblemMulig årsagLøsning
Detector chirps periodically (yellow LED)Lavt batteriUdskift begge AA-batterier.
False alarms (smoke)Cooking fumes, steam, dust, high humidityPress silence button. Ventilate the area. Relocate detector if nuisance alarms persist. Clean the detector.
Detector does not respond to test buttonNo power, dead batteries, unit malfunctionCheck AC power. Replace batteries. If still unresponsive, replace the unit.
Alarm sounds continuously without apparent hazardDust accumulation, sensor faultClean the detector thoroughly. If alarm persists, replace the unit.
Interconnected units do not all alarmWiring issue, wireless connection problem, too many unitsCheck yellow wire connections. Ensure units are within wireless range (328ft). Verify no more than 12 units are interconnected.

9. Specifikationer

SpecifikationDetalje
ModelnummerGS886F
Strømkilde120V AC with 2 AA Battery Backup
SensortypeFotoelektrisk (røg), Elektrokemisk (CO)
Alarmhøjde85 dB ved 3 meters afstand
SammenkoblingUp to 12 units (Hardwired or Wireless)
Wireless RangeOp til 100 meter i fri luft
Driftstemperatur40°F (4.4°C) til 100°F (37.8°C)
Driftsfugtighed10 % til 95 % RH (ikke-kondenserende)
Dimensioner6.1 inches (155 mm) diameter, 1.6 inches (41.8 mm) thickness
MaterialeABS + PC brandhæmmende materialer
CertificeringerUL 217, UL 2034
DækningsområdeOp til 40 kvadratmeter (430 sq ft)

10. Garanti og support

The SITERWELL Hardwired Interconnected Smoke and Carbon Monoxide Detector Combo features a 10-year sensor life, indicating the expected operational lifespan of its detection components. For specific warranty terms and conditions, or technical support, please refer to the contact information provided with your purchase documentation or visit the official SITERWELL webwebsted.

Vigtig bemærkning: Only purchase from SITERWELL's official website or authorized resellers to ensure genuine quality and support. Unauthorized use of SITERWELL branding and product information is prohibited and subject to legal action.

Various SITERWELL products with a shield logo and text warning against counterfeit products.

Image 13: A visual warning against counterfeit products, emphasizing the importance of purchasing from official SITERWELL sources for genuine quality and support.

Relaterede dokumenter - GS886F

Preview Siterwell GS886F Røg- og kuliltedetektor Brugsanvisning
Omfattende instruktionsmanual til den fastforbundne, sammenkoblede Siterwell GS886F røg- og kuliltedetektor, der dækker installation, betjening, vedligeholdelse og fejlfinding.
Preview Siterwell GS886F-H02 Kombineret røg- og kuliltealarm brugermanual
Omfattende brugermanual til Siterwell GS886F-H02 kombineret røg- og kuliltealarm. Dækker installation, betjening, vedligeholdelse, sikkerhed og fejlfinding for forbedret beskyttelse af hjemmet.
Preview Siterwell GS886F Combo Smoke and Carbon Monoxide Alarm Instruction Manual
Comprehensive instruction manual for the Siterwell GS886F Combo Smoke/CO Alarm, covering installation, operation, maintenance, safety, and troubleshooting. Includes details on alarm signals, battery replacement, and warranty information.
Preview Siterwell A8612B-6AR Kombineret røg-/CO-alarm brugermanual og installationsvejledning
Omfattende vejledning til Siterwell A8612B-6AR kombineret røg- og kuliltealarm, der dækker installation, betjening, vedligeholdelse, fejlfinding og sikkerhedsoplysninger.
Preview Installationsvejledning til fastforbundet kombineret røg-/CO-alarm - Model A8612B-6AR
En hurtig installationsvejledning til den fastmonterede kombinerede røg-/CO-alarm, model A8612B-6AR, der dækker produktdetaljer, installationstrin, ledningsføring, sammenkobling og alarmindikatorer.
Preview GS886W Kombineret røg- og CO-alarm: Installations-, betjenings- og sikkerhedsvejledning
Omfattende brugsanvisning til Siterwell GS886W Combo røg- og kuliltealarm. Lær om installation, betjening, test, vedligeholdelse og sikkerhedsretningslinjer.