Fireangel FA6720-R

FireAngel FA6720-R Varmealarm Brugermanual

Model: FA6720-R

1. Introduktion

This manual provides essential information for the installation, operation, and maintenance of your FireAngel FA6720-R Heat Alarm. Please read these instructions carefully before installation and retain them for future reference. This heat alarm is designed to detect significant increases in temperature, providing early warning of fire in areas where traditional smoke alarms may be unsuitable due to normal environmental conditions.

The FA6720-R model features a 10-year sealed-for-life battery and patented Thermistor heat sensing technology. It is an ideal replacement for the HT-630 model.

2. Sikkerhedsoplysninger

Vigtige sikkerhedsinstruktioner:

  • This heat alarm is designed for domestic use and leisure accommodation vehicles.
  • Mal ikke alarmen.
  • Do not obstruct the alarm's vents.
  • Test the alarm weekly and after any battery replacement or system changes.
  • Never ignore any alarm. Investigate the cause immediately.
  • The alarm contains a sealed-for-life battery that is not replaceable. Do not attempt to open the unit.
  • This device is certified to BS 5446-2:2003 and holds CE and UKCA marks.

3. Produktet er slutview

The FireAngel FA6720-R Heat Alarm is specifically designed for environments where smoke alarms are prone to false alarms, such as kitchens, garages, and lofts. It responds to heat rather than smoke, humidity, or cooking fumes.

FireAngel FA6720-R Heat Alarm front view

Billede: Forside view of the FireAngel FA6720-R Heat Alarm, showing the test button and FireAngel logo.

Nøglefunktioner:

  • 10 års forseglet batteri: Provides continuous power for the lifetime of the alarm, eliminating the need for battery changes.
  • Thermistor Heat Sensing Technology: Detects rapid temperature increases, ideal for areas with high humidity or fumes.
  • False Alarm Prevention: Not triggered by humidity, cooking fumes, or dust.
  • Sleep Easy Function: Allows temporary silencing of low battery alerts for 8 hours during the night.
  • Test/Stilhed knap: For easy testing and temporary silencing of false alarms.
  • Nem installation: Designed for quick and simple ceiling mounting.
FireAngel FA6720-R Heat Alarm features

Image: Visual representation of the FA6720-R Kitchen Heat Alarm highlighting its 10-year lifetime battery and immunity to humidity, cooking fumes, or dust.

4. Installation

4.1 Valg af placering:

Heat alarms are suitable for areas where smoke alarms are not recommended due to potential false alarms. Recommended locations include:

  • Køkkener
  • Garager
  • Lofts

Retningslinjer for placering:

  • Mount the alarm on the ceiling.
  • Ensure the alarm is sited at least 300 mm (12 inches) from light fittings and walls.
  • Avoid placing near air vents, fans, or areas with extreme temperature fluctuations.
FireAngel FA6720-R Heat Alarm placement guidelines

Image: Diagram illustrating suitable placement areas for the heat alarm, including kitchens, garages, and lofts, and specifying minimum distances from walls and light fittings.

4.2 Monteringsvejledning:

  1. Forbered monteringsoverfladen: Ensure the ceiling surface is clean and flat.
  2. Attach the Baseplate: Secure the removable baseplate to the ceiling using the provided screws and wall plugs. The baseplate is identical to the HT-630 model, simplifying replacement.
  3. Monter alarmen: Align the alarm with the baseplate. Push and twist the alarm clockwise onto the baseplate until it clicks securely into place.
  4. Test alarmen: After installation, press the test button to ensure the alarm is functioning correctly.
FireAngel FA6720-R Heat Alarm easy installation steps

Image: Step-by-step visual guide for installing the heat alarm, showing how to mount the baseplate and twist the alarm into place.

5. Betjeningsvejledning

5.1 Normal drift:

Once installed, the FA6720-R heat alarm is continuously monitoring for rapid temperature increases. The red LED indicator will flash periodically (approximately every 45 seconds) to indicate normal operation.

5.2 Testing the Alarm:

It is recommended to test your heat alarm weekly to ensure proper functionality.

  • Tryk og hold den store TEST/STILLE button located on the front of the alarm.
  • The alarm will sound a loud, pulsating siren at a reduced volume.
  • Slip knappen. Alarmen burde stoppe med at lyde.
  • Hvis alarmen ikke lyder, skal du se afsnittet Fejlfinding.

5.3 Alarm Condition:

If the ambient temperature in the room reaches between 54°C and 65°C, the alarm will sound a continuous, loud siren. The red LED will flash rapidly. Evacuate the premises immediately and call emergency services.

FireAngel FA6720-R Heat Alarm compact design and temperature range

Image: Illustration of the alarm's compact design, noting its activation temperature range of 54°C to 65°C and the Sleep Easy function.

5.4 Silencing False Alarms:

In the event of a false alarm (e.g., from excessive cooking fumes that might still trigger it if very dense), press the TEST/STILLE button to temporarily silence the alert for 10 minutes. The alarm will automatically reset after this period.

5.5 Sleep Easy Function (Low Battery Warning):

When the battery is nearing the end of its life, the alarm will emit a short chirp approximately every 45 seconds, accompanied by a flash of the red LED. If this occurs during the night, you can activate the Sleep Easy function:

  • Tryk på TEST/STILLE knap.
  • The low battery chirp will be silenced for 8 hours. The red LED will continue to flash.
  • The alarm will still detect heat during Sleep Easy mode.
  • Replace the alarm unit as soon as possible, and within 30 days of the first low battery warning.

6. Vedligeholdelse

Your FireAngel FA6720-R Heat Alarm requires minimal maintenance to ensure optimal performance.

  • Ugentlig test: Test the alarm weekly as described in Section 5.2.
  • Rensning: Gently vacuum the alarm's vents and exterior casing monthly using a soft brush attachment to remove dust and debris. Do not use cleaning solvents or wet cloths.
  • Batteri: The alarm features a sealed-for-life 10-year battery. It does not require replacement. The entire unit must be replaced at the end of its 10-year lifespan or when the low battery warning persists.

7. Fejlfinding

ProblemMulig årsagLøsning
Alarmen lyder ikke under testen.Enhedsfejl eller levetidsafslutning.Ensure the test button is pressed firmly. If it still doesn't sound, replace the unit immediately.
Alarmen bipper hvert 45. sekund.Advarsel om lavt batteri.Activate Sleep Easy function if at night (press test button). Replace the entire alarm unit within 30 days.
Falske alarmer forekommer ofte.Alarm placed too close to heat sources, steam, or in an unsuitable environment.Review placement guidelines (Section 4.1). Relocate the alarm if necessary. Use the silence button for temporary silencing.
Alarm sounds continuously without apparent heat source.Actual fire event or unit malfunction.Evakuer straks. If no fire is present, press the silence button. If it continues, replace the unit.

8. Specifikationer

FeatureDetalje
ModelnummerFA6720-R
AlarmtypeVarmealarm
Sensortypethermistor
Strømkilde10-Year Sealed Lithium Battery (CR123A equivalent, non-replaceable)
Aktiveringstemperatur54°C - 65°C (129°F - 149°F)
Produktmål (D x B x H)4.65" x 4.65" x 1.61" (118.1 mm x 118.1 mm x 41.3 mm)
Varens vægt4.6 ounce (131 gram)
CertificeringerCE, UKCA, BS 5446-2:2003, KM 694292
UPC816317006228
FireAngel FA6720-R Heat Alarm certifications

Image: The FireAngel FA6720-R Heat Alarm displaying UKCA and CE marks, indicating compliance with safety standards.

9. Garanti og support

The FireAngel FA6720-R Heat Alarm comes with a 5 års garanti fra købsdatoen, dækker defekter i materialer og udførelse ved normal brug. Gem venligst din købsbevis i tilfælde af garantikrav.

For technical support, warranty claims, or further information, please visit the official FireAngel webwebstedet eller kontakt deres kundeserviceafdeling. Se produktemballagen for specifikke kontaktoplysninger.

Enden på livet: After 10 years from the date of manufacture, the alarm will indicate its end of life with persistent chirps that cannot be silenced. At this point, the entire unit must be replaced.

Relaterede dokumenter - FA6720-R

Preview FireAngel HW1 Mains Powered Heat Alarm User Manual
Comprehensive user manual for the FireAngel HW1 Mains Powered Heat Alarm with 9V battery backup. Includes installation, positioning, silencing features, interconnecting options, maintenance, troubleshooting, and warranty information.
Preview FireAngel Røg- og Varmealarm Brugermanual: FA6611, FA6615, FA6620, FA6720
Omfattende brugermanual til FireAngel FA6611, FA6615, FA6620 optiske røgalarmer og FA6720 varmealarm. Dækker installation, vedligeholdelse, fejlfinding, garanti og bortskaffelse.
Preview FireAngel ZW-MODUL Installationsvejledning
Omfattende vejledning til installation og konfiguration af FireAngel ZW-MODULE trådløst forbindelsesmodul til Z-Wave-kompatible røg- og varmealarmer. Indeholder oplysninger om opsætning, batteriudskiftning, fejlfinding og garanti.
Preview FireAngel Røg- og Varmealarm Brugermanual: FA6611, FA6615, FA6620, FA6720
Brugermanual til FireAngel optiske røgalarmer (FA6611, FA6615, FA6620) og varmealarmer (FA6720). Indeholder detaljerede oplysninger om placering, installation, vedligeholdelse, fejlfinding, lydløshed og "sleep easy"-funktioner, garanti og bortskaffelsesinstruktioner for at sikre brandsikkerhed i hjemmet.
Preview FireAngel: Vigtig information til beboere i hjemmet om branddetektering og alarmsystemer
Vejledning til husejere om brug, vedligeholdelse og forståelse af FireAngel branddetekterings- og alarmsystemer, herunder handlinger under alarmer, undgåelse af falske alarmer og rutinemæssige kontroller.
Preview FireAngel: Vejledning til at undgå falske brandalarmer i beskyttede boliger
FireAngel giver vigtig vejledning til beboere og udlejere af beskyttede boliger om forebyggelse af falske brandalarmer, sikring af effektiv brandberedskabsindsats og beboernes sikkerhed.