1. Introduktion
This user manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your SHARP UL-C09EA-W Portable Air Conditioner. Please read this manual thoroughly before using the appliance and retain it for future reference.
The SHARP UL-C09EA-W is a versatile portable air conditioning unit designed to cool rooms up to 26 square meters, featuring a cooling capacity of 2.6 kW (9,000 BTU). It also includes a dehumidifier function and multiple fan speeds to ensure an ideal indoor climate.
2. Sikkerhedsoplysninger
Overhold altid følgende sikkerhedsforanstaltninger for at mindske risikoen for brand, elektrisk stød eller personskade.
- Sørg for, at strømforsyningen matcher voltage specified on the appliance's rating label (240V AC).
- Betjen ikke enheden med en beskadiget strømledning eller stik.
- Hold apparatet væk fra varmekilder og direkte sollys.
- Bloker ikke luftindtag eller -udtag.
- Ensure proper ventilation when operating the unit.
- Stik ikke genstande ind i ventilationsåbningerne.
- Tag stikket ud af enheden, før du rengør eller udfører vedligeholdelse.
- Dette apparat er ikke beregnet til brug af personer (inklusive børn) med nedsatte fysiske, sensoriske eller mentale evner, eller mangel på erfaring og viden, medmindre de har fået opsyn eller instruktion i brugen af apparatet af en person, der er ansvarlig for deres sikkerhed.
- Børn skal være under opsyn for at sikre, at de ikke leger med apparatet.
3. Produktet er slutview
3.1 Komponenter



3.2 Kontrolpanel og fjernbetjening
The unit features an intuitive LED display on the top panel and comes with a remote control for convenient operation.

The remote control (included with 2x AAA batteries) provides full functionality from a distance, allowing you to adjust settings without directly interacting with the unit.
4. Opsætning
Korrekt opsætning er afgørende for effektiv drift af dit bærbare klimaanlæg.
- Udpakning: Carefully remove the unit and all accessories from the packaging. Retain packaging for future storage or transport.
- Placering: Place the air conditioner on a flat, stable surface. Ensure there is adequate space around the unit for proper airflow (at least 20 cm from walls or furniture). The unit is equipped with castors for easy mobility.
- Installation af udstødningsslange:
- Fastgør udstødningsslangen til den dertil beregnede udgang på bagsiden af enheden.
- Connect the funnel adapter to the other end of the exhaust hose.
- Extend the exhaust hose to a window or other suitable opening to vent hot air outside. Ensure the hose is as straight and short as possible to maximize efficiency.
- Window Kit (Optional/Recommended): For optimal performance, use a window sealing kit (not explicitly listed as included, but implied by "Fenster" installation method) to prevent hot air from re-entering the room.
- Strømtilslutning: Sæt netledningen i en jordet stikkontakt (240V AC).

5. Betjeningsvejledning
Your SHARP UL-C09EA-W offers various functions for customized comfort.
5.1 Tænd/sluk
Tryk på Magt knappen på kontrolpanelet eller fjernbetjeningen for at tænde eller slukke enheden.
5.2 Valg af tilstand
Tryk på Mode knap til at gennemgå tilgængelige driftstilstande:
- Køletilstand: For active cooling of the room. Set your desired temperature between 16°C and 35°C.
- Affugterfunktion: Removes excess moisture from the air, improving comfort in humid conditions.
- Ventilatortilstand: Cirkulerer luft uden afkøling.
5.3 Justering af ventilatorhastighed
I køle- eller ventilatortilstand skal du trykke på Blæserhastighed button to select from three fan speeds: High, Medium, or Low. The noise level varies with fan speed (60-64 dB(A)).
5.4 Temperaturindstilling
Brug Temperatur op (+) og Temperatur ned (-) buttons to adjust the desired room temperature in Cooling Mode.
5.5 Timer funktion
The timer function allows you to set a specific time for the unit to turn on or off automatically.
5.6 Dvaletilstand
Activate Sleep Mode for quieter operation and gradual temperature adjustments during nighttime hours, promoting a comfortable sleeping environment.
5.7 Auto Restart Memory
I tilfælde af en magt outage, the unit will automatically restart with the last used settings once power is restored.
5.8 Børnelås
The child lock feature prevents accidental changes to settings, ensuring continuous operation as desired.
6. Vedligeholdelse
Regelmæssig vedligeholdelse sikrer optimal ydeevne og forlænger levetiden på dit klimaanlæg.
- Rengøring af luftfilteret: The air filter should be cleaned regularly (e.g., every two weeks or as needed) to maintain air quality and cooling efficiency.
- Tag stikket ud af stikkontakten før rengøring.
- Remove the air filter (refer to the full manual for location).
- Vask filteret med lunkent vand og et mildt rengøringsmiddel. Skyl grundigt, og lad det lufttørre helt, før det sættes i igen.
- Rengøring af enhedens yderside: Tør ydersiden af enheden af med en blød, damp klæde. Brug ikke skrappe kemikalier eller slibende rengøringsmidler.
- Afløbsvand: The unit may accumulate condensed water, especially in dehumidifier mode. Refer to the full manual for instructions on how to drain the water reservoir.
- Sæsonbestemt opbevaring: If storing the unit for an extended period, ensure it is thoroughly cleaned and dried. Drain all water, clean the filter, and store it in a dry, upright position.
7. Fejlfinding
Før du kontakter kundesupport, bedes du læse følgende almindelige problemer og løsninger på disse:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | Ingen strøm, netledning frakoblet, afbryder udløst. | Kontroller strømforbindelsen, sørg for at stikkontakten fungerer, nulstil afbryderen. |
| Utilstrækkelig køling. | Luftfilter snavset, udstødningsslange ikke korrekt installeret, rum for stort, vinduer/døre åbne. | Clean air filter, ensure exhaust hose is sealed, close windows/doors, check room size against unit capacity. |
| Enheden er støjende. | Unit not on a flat surface, fan speed too high, internal components vibrating. | Ensure unit is on a level surface, reduce fan speed, check for obstructions. |
| Vandlækage. | Drain plug open, water tank full (if applicable), unit tilted. | Ensure drain plug is closed, empty water tank, place unit on a level surface. |
If the problem persists after attempting these solutions, please contact SHARP customer support.
8. Specifikationer
| Feature | Specifikation |
|---|---|
| Modelnummer | UL-C09EA-W |
| Kølekapacitet | 2.6 kW / 9,000 BTU |
| Anbefalet rumstørrelse | Up to 26 sq m |
| Strømforbrug | 1,000 W |
| Energieffektivitetsklasse | A |
| Kølemiddel | R290 |
| Voltage | 240 volt (vekselstrøm) |
| Noise Level (High/Medium/Low) | 64/62/60 dB(A) |
| Airflow (High/Medium/Low) | 250 / 230 / 210 m³/hr |
| Driftstemperaturområde (køling) | 16 til 35 °C |
| Produktmål (L x B x H) | 32 x 28.6 x 70 cm |
| Produktets vægt | 24.5 kilo |
| Særlige funktioner | LED Display, Sleep Mode, 3 Fan Speeds, Remote Control, Exhaust Pipe & Funnel, Timer Function, Dehumidifier, Auto Restart Memory, Child Lock, Swing Mode |


9. Garanti og support
Your SHARP UL-C09EA-W Portable Air Conditioner comes with a warranty. Please refer to the included warranty card ("Garantiekarte") for detailed terms and conditions regarding your product's warranty coverage.
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact SHARP customer support. Contact information can typically be found on the warranty card or the official SHARP webwebsted.