1. Introduktion og overview
The IDEAL 61-347 Digital Multimeter is a versatile and robust tool designed for accurate electrical measurements. This auto-ranging True RMS (TRMS) multimeter is suitable for a wide range of applications, from basic electrical checks to more complex diagnostics.
It measures AC/DC current, AC/DC voltage, frequency, resistance, continuity, capacitance, and diodes. Additionally, it can measure temperature using the included K-Type thermocouple and detect voltage presence via its non-contact sensor.
The unit features a backlit display for clear readings in various lighting conditions, an illuminated red LED, and audible tones for critical alerts.

Figure 1.1: IDEAL 61-347 Multimeter with included soft case, test leads, batteries, and K-Type thermocouple.
2. Sikkerhedsoplysninger
Always prioritize safety when working with electrical equipment. The IDEAL 61-347 Multimeter is UL certified CAT III 1000V and CAT IV 600V, indicating its suitability for various electrical environments. Adhere to all local and national electrical codes and safety regulations.
2.1 Important Safety Features
- Lead advarsel: The multimeter provides an audible tone and displays "LEAd" if the test leads are incorrectly inserted for the selected measurement function.
- Fuse Notification: If a fuse is blown, the meter will display "FUSE" to alert the user before testing, preventing inaccurate readings or potential hazards.
- Non-Contact Voltage (NCV) Sensor: Registrerer tilstedeværelsen af AC voltage between 40V and 600V without direct contact, enhancing safety during initial checks.
- Industrial Grade Over Molding: Enhances grip and provides additional drop protection for durability.

Figure 2.1: The multimeter displaying a "LEAd" warning, indicating incorrect lead placement for the selected function.

Figure 2.2: The multimeter displaying a "FUSE" notification, indicating a blown fuse.
3. Produktfunktioner og komponenter
The IDEAL 61-347 Multimeter is designed with user convenience and functionality in mind. Familiarize yourself with its key components and features:
- Stort baggrundsbelyst LCD-display: Provides clear, easy-to-read measurements, even in low-light conditions.
- Drejeskive: Selects measurement functions (Voltage, Current, Resistance, Continuity, Capacitance, Diode, Frequency, Temperature, NCV).
- Funktionsknapper: Include SEL (Select), RANGE, MIN/MAX, HOLD, and Backlight.
- Test Lead Ports: Clearly labeled ports for current (A, µA/mA) and common (COM) measurements.
- Probe Storage: Integrated probe tip holders on the rubber boot allow for convenient storage and hands-free measurement.
- Hanging Strap Mount: Compatible with IDEAL hanging straps (sold separately) for suspending the meter from nails, screws, or magnetic surfaces.

Figur 3.1: Forside view of the IDEAL 61-347 Multimeter, highlighting the display, rotary dial, and function buttons.

Figur 3.2: Tilbage view of the multimeter, illustrating the integrated probe storage points.

Figure 3.3: Detail of the test lead probe tips, including removable CAT IV 600V caps.
3.1 Produkt overview Video
Watch this official video from IDEAL Electrical introducing their new line of electrical testers, which includes the 61-347 Multimeter. This video highlights key features and benefits across the product line.
Video 3.1: En overview of IDEAL's new line of electrical testers, showcasing features like TightSight displays, integrated flashlights, probe holders, magnetic hanging straps, and safety warnings.
4. Opsætning
4.1 Batteriinstallation
The IDEAL 61-347 Multimeter requires three (3) 1.5V AAA batteries for operation. To install or replace batteries:
- Sørg for, at multimeteret er slukket.
- Remove the screw securing the battery compartment cover on the back of the unit.
- Fjern forsigtigt dækslet.
- Insert the three AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Sæt batterirummets dæksel på igen og fastgør det med skruen.
4.2 Tilslutning af testledninger
Always connect the test leads to the correct input jacks for the desired measurement. Incorrect connection can lead to inaccurate readings or damage to the meter.
- Sæt den sorte testledning i "COM"-stikket (Common).
- For bdtage, resistance, continuity, capacitance, diode, and frequency measurements, insert the red test lead into the "VΩHz" jack.
- For current measurements up to 10A, insert the red test lead into the "A" jack.
- For microampere/milliampere current measurements, insert the red test lead into the "µA mA" jack.
5. Betjeningsvejledning
This section outlines the basic operation for common measurement functions. Refer to the full PDF manual for detailed instructions on all functions.
5.1 bindtage-måling (AC/DC)
- Drej drejeknappen til "V~" (AC-volumen)tage) or "V-" (DC Voltage) stilling.
- Connect the black test lead to the "COM" terminal and the red test lead to the "VΩHz" terminal.
- Carefully touch the test probes to the circuit points where voltage skal måles.
- Læs bindtage -værdi på displayet.

Figure 5.1: Multimeter displaying an AC voltage reading of 122.5V.
5.2 Strømmåling (AC/DC)
- Turn the rotary dial to the "A~" (AC Current) or "A-" (DC Current) position.
- Connect the black test lead to the "COM" terminal. For measurements up to 10A, connect the red test lead to the "A" terminal. For µA/mA measurements, connect to the "µA mA" terminal.
- Åbn kredsløbet og tilslut multimeteret i serie med belastningen.
- Aflæs den aktuelle værdi på displayet.
5.3 Resistance, Continuity, Capacitance, Diode, and Frequency
Select the appropriate function on the rotary dial (Ω, Ω))), F, ⟷, Hz%). Connect the test leads to the "COM" and "VΩHz" terminals. Follow standard measurement procedures for each function.
5.4 Temperaturmåling
The multimeter measures temperature in Fahrenheit (°F) or Celsius (°C) using the included K-Type thermocouple.
- Turn the rotary dial to the "°F °C" position.
- Insert the K-Type thermocouple into the "COM" and "VΩHz" jacks, observing polarity.
- Placer termoelementspidsen på det punkt, hvor temperaturen skal måles.
- Aflæs temperaturen på displayet.
5.5 Non-Contact Voltage (NCV) Detektion
Til hurtig og sikker detektering af AC-volumentage uden direkte kontakt:
- Drej drejeknappen til positionen "NCV".
- Move the top center of the meter (where the NCV sensor is located) close to the conductor or outlet.
- The meter will emit audible tones and illuminate the red LED when voltage er opdaget.
5.6 Advanced Functions (HOLD, MIN/MAX, RELATIVE, RANGE, AUTO POWER OFF)
- HOLDE: Fryser den aktuelle aflæsning på displayet.
- MIN / MAX: Records the minimum and maximum values measured during a session.
- I FORHOLD: Måler forskellen mellem en gemt referenceværdi og den aktuelle aflæsning.
- RÆKKEVIDDE: Allows manual selection of measurement range instead of auto-ranging.
- AUTO POWER OFF (APO): The meter automatically turns off after a period of inactivity to conserve battery life. This feature is selectable.

Figure 5.2: The multimeter in use, demonstrating the convenience of the hanging strap mount (strap sold separately).
6. Vedligeholdelse
6.1 Rengøring
For at bevare nøjagtigheden og levetiden på dit multimeter skal du holde det rent. Tør huset af med en klud.amp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use or storage.
6.2 Udskiftning af batteri
Replace batteries when the low battery indicator appears on the display. Refer to Section 4.1 for detailed battery installation instructions.
6.3 Udskiftning af sikringer
If the "FUSE" notification appears during current measurements, the fuse may need replacement. Always use the specified fuse type and rating to ensure safety and proper operation. Refer to the full PDF manual for specific fuse replacement procedures and ratings.
6.4 Opbevaring
When not in use, store the multimeter in its included soft case in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
7. Fejlfinding
This section provides solutions to common issues you might encounter with your IDEAL 61-347 Multimeter.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| "LEAd" displayed on screen with audible tone. | Test leads are inserted into the wrong input jacks for the selected function. | Ensure test leads are connected to the correct "COM", "VΩHz", "A", or "µA mA" jacks as per the selected measurement function. |
| "FUSE" displayed on screen. | The fuse for current measurement is blown. | Replace the blown fuse with the correct type and rating. Refer to the full manual for fuse specifications. |
| Intet eller svagt display. | Low batteries or no batteries installed. | Replace the three (3) 1.5V AAA batteries. |
| Upræcise aflæsninger. | Dirty test leads, incorrect function selected, or meter needs calibration. | Clean test leads. Verify the correct function is selected. If issues persist, contact customer support for calibration. |
8. Specifikationer
Vigtige tekniske specifikationer for IDEAL Electrical 61-347 multimeteret:
| Specifikation | Værdi |
|---|---|
| Modelnummer | 61-347 |
| Måletype | True RMS (TRMS) |
| Voltage Bedømmelse | CAT III 1000V, CAT IV 600V |
| AC / DC strøm | Op til 10 Amps |
| AC/DC Voltage | Op til 1000V |
| Temperature Range (Tester) | -40°F til 1832°F (-40°C til 1000°C) |
| Temperature Range (K-Type Thermocouple) | -40°F til 482°F (-40°C til 250°C) |
| Non-Contact Voltage Registrering | 40V til 600V AC |
| Vise | 6000 stk., baggrundsbelyst LCD |
| Strømkilde | 3 x 1.5V AAA batterier |
| Produktdimensioner | 10 x 6 x 2 tommer |
| Varens vægt | 1.4 pund |
| Fabrikant | IDEAL INDUSTRIES, INC |
| Oprindelsesland | Kina |
9. Garanti og support
For detailed warranty information, technical support, or service inquiries, please refer to the official user manual provided by IDEAL Electrical or contact their customer service directly.
A comprehensive PDF version of the user manual is available for download: