1. Introduktion
This manual provides essential information for the installation, operation, and maintenance of your Berg Water Pump, model 03.009.005. Designed as a genuine OEM part for specific Bim series units (Bim-120H/120F/160H/160F/210H/210F/2), this component ensures optimal performance and longevity when properly handled and maintained. Please read this manual thoroughly before installation or operation.
2. Sikkerhedsoplysninger
WARNING: Failure to follow these safety instructions could result in personal injury or damage to the equipment.
- Always disconnect power to the main unit before attempting any installation, maintenance, or repair on the water pump.
- Brug passende personlige værnemidler (PPE), såsom sikkerhedsbriller og handsker, under installation og vedligeholdelse.
- Sørg for ordentlig ventilation i arbejdsområdet.
- Do not operate the pump if it is visibly damaged, leaking, or if any electrical connections are exposed.
- Refer to the main equipment's instruction manual for specific electrical, plumbing, and operational requirements.
- Keep children and unauthorized personnel away from the equipment during operation and maintenance.
3. Produktet er slutview
The Berg Water Pump (Model 03.009.005) is a compact, self-contained unit designed to circulate water within compatible systems. It features an integrated motor, impeller, and clearly defined inlet/outlet ports. The unit includes a pre-attached wiring harness for electrical connection and robust mounting points for secure installation within your Bim-series equipment.

Front view of the Berg Water Pump, showing the main housing, electrical wiring, and the pump head with its outlet.

Top-down view of the Berg Water Pump, highlighting the compact design and the integrated wiring.

Side view of the Berg Water Pump, illustrating the mounting brackets and the overall dimensions.

Bag view of the Berg Water Pump, showing the inlet port and the base of the unit.
4. Opsætning
Follow these steps for proper installation of the water pump:
- Udpakning og inspektion: Carefully remove the water pump from its packaging. Inspect the pump for any visible damage that may have occurred during shipping. Do not install a damaged pump.
- Montering: Secure the pump to the designated mounting location within your Bim-series unit. Use appropriate fasteners (not included, typically provided with the main unit) to ensure the pump is level, stable, and securely attached.
- VVS tilslutning: Connect the inlet and outlet hoses from your system to the corresponding ports on the pump. Ensure all connections are tight and sealed to prevent leaks. Refer to your main equipment's plumbing diagram for correct hose routing.
- Elektrisk tilslutning: Connect the pump's wiring harness to the corresponding electrical terminals of your Bim-series unit. Verify correct polarity and ensure all electrical connections are secure and insulated to prevent short circuits.
- System Fill: Before initial operation, ensure the entire system is properly filled with water according to the main equipment's instructions. Operating the pump dry can cause severe damage.
5. Betjeningsvejledning
The Berg Water Pump operates automatically as an integral part of the larger Bim-series system (Bim-120H/120F/160H/160F/210H/210F/2). Once properly installed and the main unit is powered on, the pump will activate as required to circulate water within the system based on the main unit's operational demands.
- Indledende opstart: After installation and system fill, power on the main Bim-series unit. Observe the pump for proper water flow and listen for any unusual noises during its initial operation.
- Normal drift: The pump will cycle on and off as dictated by the main unit's controls to maintain optimal water circulation.
- Overvågning: Periodically check for consistent water flow and the absence of leaks or abnormal sounds.
6. Vedligeholdelse
Regular maintenance helps ensure the longevity and efficient operation of your water pump.
- Regelmæssig inspektion: Periodically inspect the pump, hoses, and all connections for signs of wear, leaks, corrosion, or damage. Address any issues promptly.
- Rensning: If accessible, gently clean any accumulated dust or debris from the pump's exterior using a soft, damp klæde. Brug ikke skrappe kemikalier eller slibende rengøringsmidler.
- Slangekontrol: Ensure that all connected hoses are free from kinks, blockages, or deterioration, which can impede water flow and strain the pump.
- Vinterisering (hvis relevant): If the system is located in an environment exposed to freezing temperatures, follow the main equipment's winterization procedures to properly drain the pump and prevent freeze damage.
7. Fejlfinding
This section provides solutions to common issues you might encounter with your water pump. For more complex problems, consult a qualified technician or refer to the main equipment's service manual.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Pump does not activate | Ingen strømforsyning Defekt elektrisk forbindelse Main unit control issue | Check power to the main unit Kontroller, at alle elektriske forbindelser er sikre Consult main unit's manual for control system troubleshooting |
| Ingen vandgennemstrømning eller lav vandgennemstrømning | System not filled with water Slanger knækkede eller blokerede Luft i systemet Impeller blokeret | Ensure system is properly filled Inspect and clear hoses Bleed air from the system (refer to main unit's manual) Disconnect power and inspect impeller for debris (if accessible) |
| Unusual noise (e.g., grinding, rattling) | Affald i pumpen Løs montering Kavitation (luft i pumpen) | Disconnect power and inspect for debris Spænd monteringsbeslagene Ensure proper water level and bleed air from system |
| Vandlækage | Løse slangeforbindelser Damaged hose or pump housing | Spænd alle slangeforbindelser Inspect hoses and pump housing for cracks or damage; replace if necessary |
8. Specifikationer
| Attribut | Detalje |
|---|---|
| Produktdimensioner | 2 x 2 x 2 tommer |
| Varens vægt | 1 pund (16 ounces) |
| Varemodelnummer | 03.009.005 |
| Fabrikant | Berg |
| Kompatibilitet | Bim-120H/120F/160H/160F/210H/210F/2 series |
| Del Type | Original OEM-del |
9. Garanti og support
This Berg Water Pump is a genuine OEM replacement part. For specific warranty information, terms, and conditions, please refer to the documentation provided with your main Bim-series equipment or contact Berg customer service directly. Technical support for this component is typically provided through the support channels for your complete Bim-series unit.
For further assistance, please have your product model number (03.009.005) and the model number of your main Bim-series equipment ready when contacting support.