Renogy SUNDCCB160MC2P

Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker Instruction Manual

Model: SUNDCCB160MC2P

1. Produktet er slutview

The Suntree DC Molded Case Circuit Breaker is engineered to safeguard DC electrical installations from overloads and short circuits. It incorporates both thermal and magnetic tripping mechanisms for reliable protection. Upon detecting a fault, the circuit breaker automatically interrupts the electrical circuit, preventing wire damage and reducing fire risk. This device can also be manually opened under its full rated load for electrical maintenance without sustaining damage. Designed for reversible connection, the circuit breaker can be wired in either direction and supports bidirectional current flow. Clear markings on the handle indicate the contact position (ON/OFF) at a glance. Its design facilitates easy installation on both standard DIN rails and vertical surfaces.

Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

Figure 1: Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

2. Sikkerhedsoplysninger

  • Always disconnect power before installing or servicing the circuit breaker.
  • Installation should be performed by qualified personnel in accordance with local electrical codes and standards.
  • Ensure proper wire sizing and terminal connections to prevent overheating.
  • Betjen ikke afbryderen, hvis den ser ud til at være beskadiget.
  • Brug passende personlige værnemidler (PPE) når du arbejder med elektriske systemer.

3. Installation

3.1 Pakkens indhold

  • 160A 2P DC Molded Case Circuit Breaker
  • Monteringsskruer
  • Insulation Barrier (2 pieces)
Dimensions and included components of the circuit breaker

Figur 2: Produktmål og inkluderede komponenter

3.2 Montering

The circuit breaker supports both DIN rail and vertical surface mounting. Ensure the mounting location is dry, well-ventilated, and protected from direct sunlight and extreme temperatures.

Diagram showing quick installation on DIN rail with insulation barriers

Figure 3: Quick Installation on DIN Rail

3.3 Ledningsforbindelser

Connect the DC positive and negative cables to the corresponding terminals on the circuit breaker. The circuit breaker is designed for reversible connection and functions with bidirectional current. Ensure all connections are secure and tight. Install the provided insulation barriers between terminals for enhanced safety.

Wiring diagram showing positive and negative connections to the circuit breaker

Figur 4: Tilslutningsdiagram

3.4 Sizing Tips for Circuit Breaker Selection

Proper sizing is crucial for effective protection.

  • For controller/inverter/DC device:
    1. Determine the maximum continuous operating current (current = watt/voltagog).
    2. Calculate maximum current = 1.25 x maximum continuous operating current.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
  • For solar panel:
    1. Determine the short-circuit current.
    2. Calculate maximum current = Short-circuit current x 1.25 x 1.25.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
Diagram illustrating sizing tips for circuit breakers in solar systems

Figure 5: Circuit Breaker Sizing Guidelines

4. Betjening

4.1 Tænd/sluk

To switch the circuit breaker ON, push the handle to the 'ON' position. To switch it OFF, push the handle to the 'OFF' position. The handle's position clearly indicates the contact status.

Image showing the ON and OFF positions of the circuit breaker handle

Figure 6: ON/OFF Markings

4.2 Beskyttelsesmekanismer

The circuit breaker provides protection against both overload and short-circuit conditions. In the event of an electrical fault, the breaker will automatically trip to protect the system.

Diagram illustrating overload and short-circuit protection features

Figure 7: Overload and Short-circuit Protection

5. Vedligeholdelse

After the circuit breaker has tripped due to a fault, it can be reset manually. No damage occurs to the breaker itself from tripping. Regular visual inspection for any signs of wear or damage is recommended. Ensure connections remain tight.

Diagram showing mechanical and electrical life cycles, and high electrical conductivity

Figure 8: Durability and Conductivity

6. Fejlfinding

  • Breaker trips frequently: This indicates an overload or short circuit in the system. Identify and resolve the underlying electrical issue before resetting the breaker.
  • Breaker does not reset: Ensure the fault condition has been cleared. If the breaker still does not reset, it may be damaged and require replacement.
  • Ingen strøm efter installation: Verify all wiring connections are correct and secure. Check for proper input voltage and ensure the breaker is in the 'ON' position.

7. Specifikationer

FeatureSpecifikation
MærkeRenogy
Nuværende vurdering160 Amps
Afbryder typeStandard
MonteringstypeOverflademontering
Antal polakker2
UPC810009719694
FabrikantRenogy
VarenummerSUNDCCB160MC2P
Varens vægt5.15 pund
Produktdimensioner7.9 x 3.5 x 5.3 tommer
MaterialeKobber
Inkluderede komponenter160A 2P DC Molded Case Circuit Breaker, Mounting Screws, Insulation Barrier

8. Garanti og support

Renogy offers a 1-year material and workmanship warranty for this product. For technical support or warranty claims, please visit the official Renogy webwebsted eller kontakt deres kundeservice.

For mere information, besøg Renogy Store.

Relaterede dokumenter - SUNDCCB160MC2P

Preview Generel manual til Renogy Off-Grid solcelleanlæg: Installations- og driftsvejledning
Denne manual indeholder omfattende instruktioner til installation, ledningsføring og vedligeholdelse af Renogy Off-Grid solcellesættet. Lær om sikkerhedsforanstaltninger, monteringssystemer, batterikonfigurationer og systemtilslutninger for pålidelig off-grid strøm.
Preview Brugermanual til Renogy Off-Grid solcelleanlæg: Installations-, ledningsførings- og monteringsvejledning
Omfattende brugermanual til Renogy Off-Grid solcelleanlæg, der dækker installation, ledningsføring, monteringssystemer (Z-beslag, skinne, mast), batterikonfigurationer, sikkerhedsforanstaltninger og brug af ANL-sikringer til autocampere, både og off-grid strømsystemer.
Preview Renogy Battery Shunt 300 brugermanual
Omfattende brugermanual til Renogy Battery Shunt 300, der giver vejledning i installation, drift, konfiguration og fejlfinding til intelligent batteriovervågning i solcelle- og off-grid-systemer.
Preview Renogy ONE Core Lynguide | Installation og drift
En hurtigguide til Renogy ONE Core (RSHGWSN-W02W-G3), der dækker installation, tilslutning og grundlæggende betjening. Lær, hvordan du konfigurerer din Renogy ONE Core for optimal ydeevne.
Preview Renogy BT-2 Bluetooth-modul brugermanual og tekniske specifikationer
Omfattende guide til Renogy BT-2 Bluetooth-modulet, med detaljerede oplysninger om funktioner, identifikation af dele, betjening, tekniske specifikationer og app-forbindelse til solcelleladeregulatorer.
Preview Renogy ONE Core brugermanual: Omfattende guide til energiovervågning og Smart Home-integration
Denne brugermanual indeholder detaljerede instruktioner til Renogy ONE Core, der dækker installation, betjening, funktioner som nivellering af autocampere og integration med smart home, fejlfinding og tekniske specifikationer. Lær, hvordan du overvåger og administrerer dine energisystemer effektivt.