Fireangel CO-9X10

FireAngel CO-9X10 Kuliltealarm Brugermanual

Your guide to safe and effective use

Indledning

The FireAngel CO-9X10 is a certified carbon monoxide (CO) alarm designed to provide continuous monitoring for the presence of carbon monoxide gas. Featuring an advanced electrochemical sensor developed by FireAngel, this device ensures accurate detection of CO at low concentrations, offering maximum safety for your home or workplace. It comes with a built-in lithium battery designed for a 10-year lifespan, providing reliable protection without the need for battery replacement.

This manual provides essential information on the installation, operation, maintenance, and troubleshooting of your CO-9X10 alarm. Please read it thoroughly before installation and keep it for future reference.

FireAngel CO-9X10 Carbon Monoxide Alarm front view

Figur 1: Forside view of the FireAngel CO-9X10 Carbon Monoxide Alarm. This image shows the main body of the alarm with the central test/reset button and the Power, Fault, and Alarm indicator lights.

Vigtige sikkerhedsoplysninger

Carbon monoxide (CO) is a colorless, odorless, and tasteless gas that can be fatal. This alarm is designed to detect carbon monoxide gas from any source of combustion. It is not designed to detect smoke, fire, or other gases. For optimal safety, ensure proper ventilation and regular maintenance of fuel-burning appliances.

Pakkens indhold

Kontroller venligst pakkens indhold for at sikre, at alle varer er til stede:

Opsætning og installation

Valg af placering

For optimal protection, install CO alarms in or near every room where fuel-burning appliances are located, and in sleeping areas. Consider placing an alarm on every level of your home. Avoid placing the alarm:

Montering af alarmen

The CO-9X10 can be wall-mounted or placed on a flat surface. For wall mounting:

  1. Select a suitable location, ideally at eye level or higher, but not directly on the ceiling unless specified by local regulations.
  2. Use the mounting bracket as a template to mark the drill holes on the wall.
  3. Drill two holes and insert the provided wall plugs.
  4. Screw the mounting bracket firmly to the wall.
  5. Attach the CO alarm to the mounting bracket by aligning the alarm with the bracket and twisting it clockwise until it clicks into place.
FireAngel CO-9X10 Carbon Monoxide Alarm with indicators

Figur 2: Detaljeret front view of the FireAngel CO-9X10 showing the Power, Fault, and Alarm LED indicators. This view is helpful for understanding the device's status at a glance.

FireAngel CO-9X10 Carbon Monoxide Alarm side view

Figur 3: Side view of the FireAngel CO-9X10 Carbon Monoxide Alarm, illustrating its compact profile and potential mounting features. This perspective can be useful for understanding how the device sits against a wall or on a surface.

Indledende aktivering

The CO-9X10 features a sealed-in lithium battery. The alarm will activate automatically when it is correctly attached to its mounting bracket. Upon activation, the green Power LED will flash once every 45 seconds, indicating normal operation.

Betjeningsvejledning

LED-indikatorer

Test af alarmen

It is crucial to test your CO alarm weekly to ensure it is functioning correctly.

  1. Press and hold the large "TEST/RESET" button on the front of the alarm.
  2. The alarm will sound a loud, distinctive pattern (typically 4 beeps, pause, 4 beeps) and the Red Alarm LED will flash.
  3. Release the button. The alarm should stop sounding, and the Red Alarm LED should stop flashing.
  4. If the alarm does not sound or the LEDs do not respond as described, refer to the Troubleshooting section.

Hvad skal man gøre, hvis alarmen lyder

If your CO alarm sounds, it indicates the presence of carbon monoxide. Follow these steps immediately:

  1. Evacuate immediately: Move everyone, including pets, to fresh air outdoors or open doors/windows to ventilate the area.
  2. Do not re-enter the premises until the alarm has stopped and the area has been ventilated.
  3. Ring til nødtjenester: Contact your local emergency services (e.g., 999 in the UK) or a qualified gas technician to investigate the source of the CO.
  4. Identify and resolve the source: Do not use fuel-burning appliances until they have been checked by a professional.

Stilhed funktion

The alarm may have a silence feature for nuisance alarms (e.g., from temporary high CO levels during appliance startup). Pressing the "TEST/RESET" button during an alarm may silence it for a short period. However, if the CO level remains high, the alarm will reactivate. Only use the silence feature if you are certain it is a nuisance alarm and not a genuine CO threat.

Opretholdelse

Regelmæssig rengøring

Clean your CO alarm regularly to prevent dust and debris from affecting its performance. Use a soft, damp cloth to wipe the exterior. Do not use cleaning solvents or sprays directly on the alarm.

Battery Life and End-of-Life Signal

The FireAngel CO-9X10 is equipped with a sealed-in lithium battery designed to last for 10 years. When the alarm reaches the end of its operational life, it will emit a specific end-of-life signal (e.g., two short beeps every 45 seconds, accompanied by the Amber Fault LED flashing). When this occurs, the alarm needs to be replaced immediately.

Fejlfinding

ProblemMulig årsagLøsning
Alarm sounds continuously (Red LED flashing)High level of Carbon Monoxide detected.Evakuer straks. Call emergency services. Do not re-enter until cleared by professionals.
Amber Fault LED flashing / Alarm chirping intermittentlyLow battery or fault detected.The battery is sealed and cannot be replaced. If the alarm is chirping due to low battery or fault, it has reached its end-of-life or is malfunctioning. Udskift alarmen med det samme.
Alarm does not sound when Test button is pressedAlarm malfunction or end-of-life.Ensure the alarm is properly mounted. If it still doesn't respond, the alarm is faulty or has reached its end-of-life. Udskift alarmen med det samme.
Green Power LED not flashingAlarm not activated or malfunction.Ensure the alarm is securely attached to its mounting bracket. If the issue persists, the alarm may be faulty. Udskift alarmen.

Specifikationer

FeatureDetalje
ModelnummerCO-9X10
Sensortypeelektrokemisk
StrømkildeSealed-in Lithium Battery (10-year life)
AlarmvolumenHørbar
Produktdimensioner11.2 x 3.5 x 7.2 cm
Varens vægt150 g
CertificeringerBSI EN50291-1:2010 and EN50291-2:2010 Certified
UPC816317003609

Garanti og support

FireAngel products are manufactured to the highest standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official FireAngel website. If you experience any issues with your CO-9X10 alarm or require technical assistance, please contact FireAngel customer support. Do not attempt to repair the alarm yourself.

Kontaktoplysninger: Please refer to the FireAngel website or your purchase documentation for the most up-to-date contact details for customer support in your region.

Relaterede dokumenter - CO-9X10

Preview FireAngel CO-9X Kuliltedetektor med 7 års levetid brugermanual
Omfattende brugermanual til FireAngel CO-9X 7 års levetid kuliltealarm for giftig gas. Lær om installation, betjening, vedligeholdelse, sikkerhed og fejlfinding.
Preview FireAngel FA6813 Carbonmonoxidalarm brugermanual
Omfattende brugermanual til FireAngel FA6813 kuliltealarmen, der dækker installation, betjening, vedligeholdelse, fejlfinding og sikkerhedsoplysninger.
Preview FireAngel SCB10 Kombination af røg- og kuliltealarm brugermanual
Brugermanual til FireAngel SCB10, en kombineret røg- og kuliltealarm, der indeholder omfattende instruktioner om installation, betjening, vedligeholdelse og sikkerhed til brug i private hjem.
Preview FireAngel FA6812/FA6813 Kuliltealarm Brugermanual
Brugermanual til FireAngel FA6812 og FA6813 kuliltealarmer (CO), der indeholder instruktioner til installation, betjening, sikkerhed og vedligeholdelse.
Preview FireAngel Multisensor Plus brugermanual: Røg-, varme- og CO-detektor
Omfattende brugermanual til FireAngel Multisensor Plus og Multisensor Plus Kitchen, med detaljerede oplysninger om installation, betjening, sikkerhed, fejlfinding og tekniske specifikationer for røg-, varme- og kuliltedetektion.
Preview FireAngel CO-alarmer FA3313, FA3322, FA3328, FA3820 brugermanual
Omfattende brugermanual til FireAngel kuliltealarmer (modellerne FA3313, FA3322, FA3328, FA3820), der dækker placering, installation, CO-alarmregistrering, vedligeholdelse, statusindikatorer, Sleep Easy-funktionen, LCD-skærmindikatorer og tekniske specifikationer. Indeholder oplysninger om garanti og bortskaffelse.