Indledning
This manual provides essential information for the safe and effective use of your ELEGRP Manual Reset Single Outlet GFCI Adapter. This 15 AMP grounded 3-prong adapter is designed for indoor use, offering portable ground fault circuit interrupter protection.

Billede: Forside view of the yellow ELEGRP Manual Reset Single Outlet GFCI Adapter.
Vigtige sikkerhedsoplysninger
Læs og forstå altid alle instruktioner, før du bruger dette produkt. Manglende overholdelse af disse instruktioner kan resultere i elektrisk stød, brand eller alvorlig personskade.
Generelle sikkerhedsretningslinjer
- This GFCI adapter is UL & CUL Listed, ensuring it meets high safety standards.
- Do not use where exposed to rain or excessive moisture. This product is designed for indoor use.
- Always ensure the adapter is firmly inserted into the wall receptacle.
- The GFCI automatically conducts a self-test every 5 seconds to ensure continuous protection.
- This device prevents unmonitored equipment startup; a manual reset is required after a GFCI trip or power outage.

Billede: Bagside view of the GFCI adapter showing the NEMA 5-15P plug and warning labels.
Produkt overview
The ELEGRP GFCI Adapter provides essential ground fault protection for your electrical devices. It features a compact design and clear indicators for ease of use.

Image: Diagram highlighting the LED Power "ON" Light, Reset Button, Test Button, and NEMA 5-15R Receptacle.
Nøglekomponenter
- LED Power "ON" Light: Indicates when power is available.
- Reset Button (Red): Used to restore power after a trip.
- Test Button (Black): Used to manually test the GFCI function.
- NEMA 5-15R Receptacle: The outlet where you plug in your device.
- NEMA 5-15P stik: The prongs that insert into a standard wall outlet.

Image: A hand holding the compact yellow GFCI adapter, demonstrating its small size.
Specifikationer
| Feature | Detalje |
|---|---|
| Modelnummer | 4920703e-cc8f-4870-88be-e4029bffdb1b |
| Voltage | 125 volt |
| Ampslet Kapacitet | 15 Amps |
| Power Rating | 1875 watt |
| Plug-format | A- US style (3-prong grounded) |
| Nulstil type | Manuel nulstilling |
| Farve | Gul |
| Certificering | UL-listet |
| Dimensioner (ca.) | 3.6 cm (H) x 2.01 cm (B) x 1.52 cm (D) |

Image: Technical drawing showing the dimensions of the GFCI adapter.
Opsætningsinstruktioner
- Plug into Receptacle: Insert the ELEGRP GFCI Adapter firmly into a standard 125V AC, 3-prong grounded wall outlet.
- Nulstil GFCI: After plugging in, press the red NULSTIL button. The LED Power "ON" Light should illuminate green, indicating power is available.
- Tilslut din enhed: Plug the electrical device you wish to protect into the NEMA 5-15R receptacle on the GFCI adapter.

Image: The yellow GFCI adapter plugged into a white wall outlet, demonstrating portable protection.

Image: A man operating a power sander, with the GFCI adapter providing safety for the tool.
Betjeningsvejledning
Power On/Reset
To ensure power is supplied through the GFCI adapter, press the red NULSTIL button. The green LED indicator will light up when power is active.
Testing the GFCI
It is crucial to test the GFCI adapter regularly (e.g., monthly or before each use with critical equipment) to ensure proper function.
- With the GFCI adapter plugged in and the green LED illuminated, press the black PRØVE knap.
- The green LED should turn off, and power to the connected device should be interrupted. This indicates the GFCI has tripped successfully.
- To restore power, press the red NULSTIL button. The green LED should re-illuminate.
- If the GFCI does not trip when the PRØVE button is pressed, or if it does not reset after tripping, do not use the adapter. Consult the troubleshooting section.
Automatisk selvtest
The ELEGRP GFCI adapter features a patented self-test mechanism that automatically performs a diagnostic check every 5 seconds when power is on. This exceeds standard UL requirements and ensures continuous protection.
Video: En overview of ELEGRP GFCI G20 Series products, demonstrating features like button press testing, self-test functionality, durability, and various application types including the outlet adapter.
Opretholdelse
Keep the GFCI adapter clean and free from dust and debris. Wipe with a dry cloth as needed. Do not use liquid cleaners.
Regularly perform the manual test as described in the "Testing the GFCI" section to ensure the unit is functioning correctly.
Fejlfinding
GFCI Does Not Reset
- Sørg for, at adapteren er sat ordentligt i stikkontakten.
- Disconnect the connected device from the GFCI adapter. If it then resets, the issue may be with the device.
- If the GFCI still does not reset, it may be faulty or there might be a wiring issue in your home's electrical system. Discontinue use and consult a qualified electrician.
GFCI Trips Frequently
- This indicates a ground fault or an overload condition.
- Check the connected device for damage or malfunction.
- Ensure the total power draw of the connected device does not exceed the adapter's 1875W rating.
- If the issue persists, discontinue use and have the connected device or your electrical system inspected by a professional.
Garanti og support
ELEGRP products are designed and manufactured with a focus on electrical safety and undergo rigorous testing to meet global safety certifications, including UL & CUL Listing.
For product support or inquiries, please refer to the contact information provided with your purchase or visit the official ELEGRP webwebsted.
Bortskaffelse af produkt
Please dispose of this product responsibly according to local electronic waste regulations. Do not dispose of with general household waste.