1. Introduktion
This manual provides essential information for the installation, operation, and maintenance of your Daikin ARXC35C ATXC35C Inverter Air Conditioner. Please read this manual thoroughly before using the unit to ensure proper function and to prevent damage or injury. Keep this manual for future reference.
2. Sikkerhedsoplysninger
Always observe the following safety precautions to reduce the risk of electric shock, fire, or injury.
- Professionel installation: Installation, relocation, and maintenance of this unit must be performed by a qualified service technician. Improper installation can lead to electric shock, fire, or water leakage.
- Elektrisk sikkerhed: Ensure the power supply matches the unit's specifications. Do not operate with wet hands. Never attempt to repair or modify the unit yourself.
- Kølemiddelhåndtering: The unit uses R32 refrigerant. This refrigerant is mildly flammable. Ensure proper ventilation during installation and servicing. Do not puncture or burn the refrigerant circuit.
- Børn og udsatte personer: Dette apparat kan bruges af børn i alderen 8 år og derover og personer med nedsatte fysiske, sensoriske eller mentale evner eller mangel på erfaring og viden, hvis de har fået opsyn eller instruktion i brugen af apparatet på en sikker måde og forstår de involverede farer. . Børn må ikke lege med apparatet. Rengøring og brugervedligeholdelse må ikke udføres af børn uden opsyn.
- Klarering: Maintain adequate clearance around the indoor and outdoor units for proper airflow and maintenance.
3. Produktet er slutview
The Daikin ARXC35C ATXC35C is a split-system air conditioner designed for efficient cooling and heating. It consists of an indoor unit (ARXC35C) and an outdoor unit (ATXC35C).
Indoor Unit (ARXC35C)

Figure 3.1: Daikin ARXC35C Indoor Unit. This image shows the white, sleek indoor unit of the Daikin air conditioner, typically mounted high on a wall, with its front panel closed.
Outdoor Unit (ATXC35C)

Figure 3.2: Daikin ATXC35C Outdoor Unit. This image displays the beige-colored outdoor unit with a large fan grille, typically placed outside the building, responsible for heat exchange.
4. Opsætning og installation
Installation of the Daikin ARXC35C ATXC35C air conditioner requires specialized tools and knowledge. It is mandatory to have the unit installed by a certified HVAC professional to ensure safety, optimal performance, and warranty validity.
Vigtige overvejelser ved installation:
- Beliggenhed: Choose a location for both indoor and outdoor units that allows for proper airflow, minimal obstruction, and easy access for maintenance. Avoid direct sunlight or heat sources for the outdoor unit.
- Elektrisk tilslutning: Ensure a dedicated power circuit with appropriate voltage (240V) and circuit breaker protection is available.
- Kølemiddelrør: The unit comes pre-charged with R32 refrigerant for up to 7 meters of piping. For longer runs, additional refrigerant must be added by a professional.
- Dræning: Proper drainage for condensate water from the indoor unit is crucial to prevent water damage.
Refer to the detailed installation manual provided with the unit for specific instructions, diagrams, and safety warnings for installers.
5. Betjeningsvejledning
Your Daikin ARXC35C ATXC35C air conditioner is controlled via a wireless remote control (not pictured). Familiarize yourself with the remote control's buttons and display.
Grundlæggende betjening:
- Tænd/sluk: Tryk på ON/OFF knappen for at starte eller stoppe enheden.
- Valg af tilstand: Brug MODE button to cycle through operating modes:
- FEDT NOK: Til afkøling af rummet.
- VARME: For heating the room (heat pump function).
- VENTILATOR: Cirkulerer luft uden afkøling eller opvarmning.
- TØRRE: Affugter rummet.
- BIL: Vælger automatisk køling eller opvarmning baseret på rumtemperatur.
- Temperaturjustering: Brug TEMP ▲ / ▼ for at indstille den ønskede temperatur.
- Blæserhastighed: Tryk på FAN button to adjust the fan speed (Auto, Low, Medium, High).
- Svinge: Brug SWING button to adjust the airflow direction.
- Timer funktion: Set the unit to turn on or off automatically at specified times using the TIMER TIL/FRA knapper.
Særlige funktioner:
- Inverter teknologi: The inverter compressor adjusts its speed to maintain a stable temperature, leading to energy savings and quieter operation.
- Kraftig tilstand: Provides rapid cooling or heating for a short period.
- Økonomitilstand: Reduces power consumption for energy-efficient operation.
- Stille drift: Selectable fan settings for reduced noise levels.
6. Vedligeholdelse
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always turn off the power supply to the unit before performing any maintenance.
Brugervedligeholdelse:
- Rengøring af luftfilter: Clean the air filters every two weeks or more frequently depending on usage and air quality. Open the front panel of the indoor unit, remove the filters, wash them with water, dry thoroughly, and reinsert.
- Udvendig rengøring af enheden: Wipe the indoor and outdoor unit exteriors with a soft, damp cloth. Do not use harsh detergents, solvents, or abrasive cleaners.
Professionel vedligeholdelse:
It is recommended to have a qualified technician perform a comprehensive service check at least once a year. This includes:
- Checking refrigerant levels and leaks.
- Cleaning the outdoor unit coils.
- Inspecting electrical connections.
- Checking drainage system.
7. Fejlfinding
Før du kontakter service,view følgende almindelige problemer og deres mulige løsninger.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden fungerer ikke | No power; Remote control batteries low; Timer set to OFF. | Check power supply/circuit breaker; Replace remote batteries; Cancel timer setting. |
| Utilstrækkelig køling/opvarmning | Dirty air filters; Doors/windows open; Temperature setting incorrect; Obstruction to airflow. | Clean air filters; Close doors/windows; Adjust temperature; Remove obstructions. |
| Usædvanlig støj | Loose parts; Unit not level; Normal operating sounds (e.g., refrigerant flow). | Check for loose parts (contact professional); Ensure unit is level; If noise is excessive or unusual, contact service. |
| Vandlækage fra indendørsenhed | Tilstoppet afløbsslange; Forkert installation. | Contact a qualified technician to inspect and clear the drain hose or re-evaluate installation. |
If the problem persists after attempting these solutions, or if an error code appears on the display, contact a qualified Daikin service technician for assistance. Do not attempt to repair the unit yourself.
8. Specifikationer
The following table outlines the key technical specifications for the Daikin ARXC35C ATXC35C air conditioner.
| Feature | Specifikation |
|---|---|
| Mærke | Daikin |
| Modelnummer | ARXC35C (Indoor), ATXC35C (Outdoor) |
| Kølekapacitet | 12000 BTU |
| Energieffektivitet (køling) | A++ |
| Energieffektivitet (opvarmning) | A+ |
| Kølevæsketype | R32 |
| Voltage | 240 volt |
| Wattage | 3530 W |
| Installationsmetode | Opdelt system |
| Særlige funktioner | Inverter kompressor |
| Pakkedimensioner | 92 x 83 x 35 cm |
| Varens vægt | 40.3 kg |
| SEER (Sæsonbestemt energieffektivitetsforhold) | 5 |
9. Garanti og support
Your Daikin ARXC35C ATXC35C air conditioner is covered by a manufacturer's warranty. The specific terms and duration of the warranty may vary by region and retailer. Please refer to the warranty card included with your product or contact your point of purchase for detailed information.
For technical support, service requests, or inquiries regarding your unit, please contact Daikin customer service or an authorized Daikin service center. Ensure you have your model number (ARXC35C ATXC35C) and purchase details available when contacting support.
You can find contact information for Daikin support on their official website or through your local Daikin distributor.