SKINACT F-300A

SKINACT Digital Euro Facial Steamer F-300A with LED Magnifying Lamp Instruktionsmanual

Model: F-300A

1. Introduktion

Congratulations on your purchase of the SKINACT Digital Euro Facial Steamer F-300A with LED Magnifying Lamp. This manual provides essential information for the safe and effective assembly, operation, and maintenance of your new equipment. Please read all instructions carefully before use and retain this manual for future reference.

SKINACT Digital Euro Facial Steamer F-300A with LED Magnifying Lamp

Figure 1: Complete assembly of the SKINACT Digital Euro Facial Steamer F-300A.

2. Sikkerhedsoplysninger

For at sikre sikker drift og forhindre personskade eller beskadigelse, bedes du følge følgende sikkerhedsretningslinjer:

  • Hold enheden væk fra børn.
  • Efterlad ikke enheden uden opsyn under drift.
  • Allow the unit to cool down completely before handling or refilling the water reservoir.
  • Brug kun destilleret vand for at forhindre mineralophobning og sikre optimal ydeevne.
  • Avoid spilling water on the unit's electrical components. If spills occur, immediately wipe them dry and disconnect power.
  • Ensure the power cord is securely plugged into an appropriate electrical outlet (110V, 750W, 50-60Hz).
  • Do not over-tighten bolts during assembly; snug is sufficient.
  • When adjusting the sliding bar, hold it firmly to prevent it from springing out and causing injury.

3. Produktkomponenter overview

The SKINACT Digital Euro Facial Steamer F-300A includes the following main components:

  • Steamer Head with Movable Arm and Rotational Tip
  • LED-forstørrelse Lamp med justerbar arm
  • Digital Control Panel (Energy, Timer, Ozone, Vapor controls)
  • Water Beaker (Glass Jar) with Gasket
  • Aroma Basket
  • Height Adjustment Bar (Sliding Bar)
  • Five-Legged Base with Casters
  • Pressing Plate and various bolts/washers for assembly
  • Strømledning
Close-up of SKINACT Digital Euro Facial Steamer F-300A top unit

Figure 2: Top unit of the steamer showing the steamer arm, magnifying lamp, and control panel.

4. Monteringsvejledning

This section guides you through the assembly process. For a visual guide, please refer to the official product video below.

Video 1: Assembly guide for the SKINACT Digital Euro Facial Steamer F-300A with LED Magnifying Lamp.

4.1. Frakobling

Carefully unbox all components. Locate the user manual and the bag of parts (containing small bolts, a large bolt, washers, and a spanner). Retain original packaging until you confirm the unit is fully functional.

4.2. Basissamling

  1. Lay the five-leg base on a flat surface.
  2. Insert each of the five wheel legs into the base slots. Ensure the holes on the legs are visible, indicating correct placement.
  3. Place the pressing plate onto the assembled legs, ensuring its small lips align with the corresponding holes on the legs.
  4. Attach the five small bolts (each with one small washer) into the aligned holes. Hand-tighten them first, then use the provided spanner to snug them securely. Do not over-tighten.

4.3. Height Adjustment Bar Installation

  1. Take the height adjustment bar and place it face down.
  2. Insert the assembled base onto the height adjustment bar, aligning the bar with the large center hole of the pressing plate.
  3. Secure the base to the height adjustment bar using the large bolt, one lock washer, and one regular washer. Hand-tighten, then use the spanner to snug it. Do not over-tighten.

4.4. Magnifying Lamp Vedhæftet fil

  1. Loosen the tightening thimble on the top of the height adjustment bar.
  2. Insert the sliding bar into the height adjustment bar. Forsigtighed: A spring is inside; hold the sliding bar firmly to prevent injury.
  3. Place the magnifying lamp base onto the sliding bar and tighten the thimble to secure it at your desired height.
  4. Attach the LED magnifying lamp by inserting its bottom bar into the slot on the magnifying lamp base. Ensure it is fully seated.
SKINACT Digital Euro Facial Steamer F-300A showing height adjustment

Figure 3: The steamer and magnifying lamp assembly, illustrating height adjustment capabilities.

4.5. Steamer Head Attachment

  1. Bring the steamer head and arm assembly to the sliding bar.
  2. Locate the bar under the steamer head and insert it into the top of the sliding bar. Ensure the steamer head is securely in place before releasing det.

5. Betjeningsvejledning

5.1. Water Beaker Setup

  1. Place the gasket onto the top of the water beaker, ensuring the longer lip of the gasket goes around the outside of the beaker top. Confirm it is firmly sealed.
  2. Insert the assembled beaker into its place on the bottom of the steamer head. The outside of the beaker gasket should fit flush inside the lip on the bottom of the steamer head.
  3. If necessary, loosen the tray knob until the tray fits directly under the beaker. Once positioned, tighten the tray knob until snug to secure the beaker.

5.2. Adding Distilled Water

  1. Remove the top cover from the steamer head.
  2. Take out the small steel cup and herbs filter.
  3. Carefully pour distilled water into the opening. Avoid spilling water on the unit's top surface.
  4. Ensure the water level is above the 'MIN' line but below the 'MAX' line indicated on the beaker.
  5. If using an herbs bag, place it into the steel cup, then place the steel cup into the herbs filter. Reinsert the filter and cup into the opening, and close the top cover.

5.3. Powering On and Adjusting Settings

  1. Plug the steamer's power cord into the back of the unit, then into a wall outlet.
  2. Plug the LED magnifying lamp's power cord into the designated outlet on the back of the steamer unit.
  3. Ensure the main power switch on the back of the steamer is in the 'ON' (line) position.
  4. Press the 'VAPOR' button on the control panel to turn on the steamer.
  5. Adjust the 'ENERGY' level using the '+' and '-' buttons. Set to level 5 for quickest boiling.
  6. Set the 'TIMER' using the '+' and '-' buttons. 15 minutes is recommended for most treatments.
  7. To activate the Ozone feature, press the 'OZONE' button. This makes the steam more visible.
Close-up of SKINACT Digital Euro Facial Steamer F-300A control panel

Figure 4: Digital control panel for adjusting energy, timer, vapor, and ozone settings.

5.4. Steamer Arm and Magnifying Lamp Justeringer

  • The steamer arm head can rotate 360 degrees and articulates for precise positioning.
  • The LED magnifying lamp head swivels easily and can be raised or lowered. Loosen the black knob to move the lamp head around, then tighten to secure.
  • Turn the magnifying lamp on/off using the green switch on its head.
SKINACT Digital Euro Facial Steamer F-300A with adjustable steamer arm

Figure 5: The adjustable steamer arm provides flexibility in positioning.

6. Vedligeholdelse

Regular maintenance ensures the longevity and optimal performance of your steamer:

  • Cleaning the Water Beaker: If using only distilled water, clean the beaker once per week. If using regular tap water, clean every few days to prevent mineral buildup. Refer to the full user manual for detailed cleaning instructions.
  • Afkalkning: Periodically descale the heating element if mineral buildup occurs. Consult the full manual for recommended descaling procedures.
  • Generel rengøring: Tør enhedens yderside af med en blød, tør klud.amp klæde. Undgå slibende rengøringsmidler.

7. Fejlfinding

If you encounter issues with your steamer, refer to the following common troubleshooting tips:

  • Ingen damp: Ensure the unit is plugged in, the main power switch is ON, the water level is above 'MIN', and the 'VAPOR' button is pressed. Check that the energy level is set to at least 1.
  • Vandlækage: Verify the water beaker gasket is properly seated and the beaker is securely placed in the steamer head. Ensure no water was spilled during refilling.
  • Forstørrelse Lamp Virker ikke: Tjek om lamp's power cord is securely plugged into the steamer's outlet and the green switch on the lamp head is ON.
  • Enheden tænder ikke: Confirm the power cord is fully inserted into both the unit and the wall outlet, and the main power switch on the back is in the 'ON' position.

For more detailed troubleshooting, please consult the comprehensive user manual.

8. Specifikationer

MærkeSKINACT
ModelnavnDigital Euro Facial Steamer (F-300A)
Voltage110V
Magt750 W
Frekvens50-60 Hz
TimerUp to 60 minutes (digital)
Forstørrelsesglas LampLED, lasts +15000hrs
Steamer FeaturesMetal Body, Glass Jar, Movable Arm with Rotational Tip, Ozone Capability, Aroma Basket, Energy Adjustment Control
MaterialeMetal
FarveSort, hvid
Pakkedimensioner27 x 15 x 14 tommer
Vægt32 pund

9. Garanti og support

For warranty information, please refer to the documentation included with your product or contact SKINACT customer support. If you require assistance with assembly, operation, or troubleshooting beyond what is covered in this manual, please visit the SKINACT-butikken på Amazon eller kontakt deres officielle supportkanaler.

Relaterede dokumenter - F-300A

Preview Brugervejledning til Pro 11 Function hudplejesystem
Brugervejledning til Pro 11 Function Skin Care System (SKU16147) fra SkinAct, der beskriver dets forskellige funktioner, fordele, betjeningstrin og forholdsregler til professionel æstetisk brug.
Preview SkinAct ARC LED lysterapikuppel (SKU25538) brugermanual og vejledning
Dette dokument indeholder omfattende instruktioner, sikkerhedsretningslinjer, vedligeholdelsesprocedurer og tekniske specifikationer for SkinAct ARC LED Light Therapy Dome (SKU25538), et professionelt skønhedsapparat.
Preview Sikkerhedsoplysninger om SkinAct roterende behandlingsbrikse
Væsentlige sikkerhedsretningslinjer for betjening af SkinAct hydrauliske og elektriske roterende ansigtsmadrasser og behandlingsborde med fokus på stabilitet og klientsikkerhed.
Preview SkinAct Roll-on voksvarmer med to eller tre håndtag - brugermanual
Officiel brugermanual til SkinAct Roll On Wax Warmer (SKU17584), der indeholder instruktioner til brug, vedligeholdelse, sikkerhedsadvarsler og tekniske specifikationer til professionel og personlig hårfjerning.
Preview Bellage elektrisk behandlingsbriks brugermanual - SkinAct
Brugermanual til SkinAct Bellage fuldt elektrisk behandlingsbord med 4 motorer (stol), der indeholder instruktioner, advarsler, specifikationer, installationsvejledning, brug af controller, justeringer og vedligeholdelsesoplysninger.
Preview SkinAct Lusso IV-stolens brugermanual og monteringsvejledning
Omfattende brugermanual og samlevejledning til SkinAct Lusso IV elektriske lænestol. Lær, hvordan du samler, betjener og vedligeholder din Lusso IV-stol.