Testo 0563 4200

Brugermanual til Testo 420 Balometer-sæt

Model: 0563 4200

1. Introduktion

The Testo 420 Balometer Kit is designed for precise measurement of airflow in large air supplies, returns, and swirl outlets. It provides reliable data for air velocity, volume flow, absolute and differential pressure, air temperature, and relative humidity. This manual provides essential information for the correct setup, operation, and maintenance of your device.

Testo 420 Balometer Kit assembled

Figure 1: The Testo 420 Balometer Kit, fully assembled with the control unit visible at the base.

2. Opsætning

  1. Udpakning: Carefully remove all components from the packaging. Verify that all items listed in the delivery scope are present: Testo 420 airflow capture hood control unit, USB cable, batteries, flow straightener, and soft-shell protective case.
  2. Batteri installation: Open the battery compartment on the control unit and insert the 4 AA batteries provided, ensuring correct polarity.
  3. Control Unit Attachment: Securely attach the control unit to the base of the airflow capture hood. Ensure it clicks into place.
  4. Flow Straightener Installation: Insert the flow straightener into the hood's base. This component is crucial for converting turbulent air into a uniform flow, ensuring accurate measurements.
  5. Emhætte samling: Extend the fabric hood and attach it to the frame. Ensure it is taut and properly secured to prevent air leakage during measurements.
Bund view of Testo 420 Balometer with flow straightener

Figur 2: Nederst view of the Testo 420 Balometer, showing the integrated flow straightener designed to ensure accurate airflow readings.

3. Betjeningsvejledning

3.1 Powering On and Initial Calibration

  1. Press the power button on the control unit to turn on the device.
  2. Allow the device to perform its automatic zeroing process. This ensures higher accuracy for low-pressure measurements.

3.2 Udførelse af målinger

The Testo 420 measures various parameters including air velocity, volume flow, absolute and differential pressure, air temperature, and relative humidity.

  1. Position the balometer hood over the air outlet or inlet to be measured. Ensure a complete seal around the opening to prevent air leakage.
  2. Read the measurements directly from the control unit's display. The display is tiltable for ergonomic viewing, especially during overhead measurements.
  3. For measurements in ducts, the removable control unit can be combined with an optional pitot tube and connection hose (sold separately).
Testo 420 Balometer in use on a ceiling vent

Figure 3: A technician using the Testo 420 Balometer to measure airflow from a ceiling vent, demonstrating its application for large air supplies.

3.3 Bluetooth Connectivity and App Usage

The Testo 420 features Bluetooth connectivity for remote monitoring and documentation via the MeasureQuick App.

  1. Download the MeasureQuick App on your smartphone or tablet.
  2. Enable Bluetooth on your mobile device and the Testo 420 control unit.
  3. Pair the devices following the app's instructions.
  4. Monitor all measurements remotely and send results directly from the job site for convenient documentation.
Testo 420 Balometer with smartphone app display

Figure 4: The Testo 420 Balometer in operation, with a user monitoring real-time data on a smartphone via the MeasureQuick App.

4. Vedligeholdelse

4.1 Rengøring

  • Wipe the exterior of the control unit and hood with a soft, damp klæde. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Ensure the flow straightener is free from dust and debris. Clean gently if necessary.

4.2 Udskiftning af batteri

Replace batteries when the low battery indicator appears on the display. Use only specified AA batteries.

4.3 Opbevaring

When not in use, store the Testo 420 Balometer Kit in its soft-shell protective case in a dry, dust-free environment. Remove batteries if storing for extended periods.

Testo 420 Balometer in its soft-shell protective case

Figure 5: The Testo 420 Balometer Kit packed in its soft-shell protective case, highlighting its portability and ease of storage.

5. Fejlfinding

  • Enheden tænder ikke: Kontroller batteriinstallation og opladningsniveau. Udskift batterierne om nødvendigt.
  • Unøjagtige aflæsninger: Ensure the hood forms a complete seal around the air outlet. Verify the flow straightener is correctly installed and clean. Allow for automatic zeroing before measurement.
  • Problemer med Bluetooth-forbindelse: Ensure Bluetooth is enabled on both the control unit and your mobile device. Restart both devices and try pairing again.
  • Appen viser ikke data: Check if the app is updated to the latest version. Ensure the device is properly paired and within Bluetooth range.

6. Specifikationer

ParameterMåleområdeNøjagtighed
Temperatur-4° til 158 °F / -20 til +70 °C±1 °F (32° to 158 °F) / ±0.5 °C (0 to +70 °C) / ±1.4 °F (-4° to 32 °F) / ±0.8 °C (-20 to +0 °C)
Fugtighed0 til 100 % rH±1.8 %rH + 3 % of mv at +77 °F / ±1.8 %RH + 3 % of mv at +25 °C (5 to 80 %rH)
Differenstryk-0.480 to 0.480 InH2O / -120 to +120 Pa±2 % of mv + 0.002 InH2O at +72 °F, 405 InH2O / ±2 % of mv + 0.5 Pa at +22 °C, 1013 hPa
Absolut pres280 to 440 InH2O / 700 to 1100 hPa±1 InH2O / ±3 hPa
Volumenstrøm24 to 2354 CFM / 40 to 4000 m3/h±3 % of mv + 7 CFM at +72 °F / ±3 % of mv + 12 m3h at +22 °C; 405 InH2O (50 to 2060 CFM) / 1013 hPa (85 to 3500 m3/h)
Dimensions (Standard hood)24 x 24 tommer / 610 x 610 mm
Vægt102 oz. / 2900 g
Batterilevetid40 timer
Varemodelnummer0563 4200
Batterier4 AA-batterier påkrævet (medfølger)
MaterialeNylon

7. Garantioplysninger

For detailed warranty information regarding your Testo 420 Balometer Kit, please refer to the documentation provided with your purchase or visit the official Testo webGarantibetingelserne kan variere fra region til region.

8. Support

If you require technical assistance, have questions about your Testo 420 Balometer Kit, or need to order replacement parts, please contact Testo customer support. Contact information can typically be found on the Testo official webwebsted eller i produktemballagen.

Du kan også besøge Testo-butik på Amazon for yderligere produktinformation og tilbehør.

Relaterede dokumenter - 0563 4200

Preview testo 420 Volumenstrommesshaube Bedienungsanleitung
Bedienungsanleitung für die testo 420 Volumenstrommesshaube, die detaillierte Informationen zu Betrieb, teknisken Daten, Sicherheit og Wartung liefert.
Preview Testo 420 Flow Hood Brugsanvisning
Omfattende brugsanvisning til Testo 420 Flow Hood, der beskriver dens funktioner, betjening, vedligeholdelse og tekniske specifikationer for nøjagtige luftstrømsmålinger i HVAC-systemer.
Preview Brugermanual til Testo Smart Probes: Funktioner, specifikationer og betjening
Omfattende brugermanual til Testo Smart Probes, med detaljerede beskrivelser af funktioner, tekniske specifikationer, sikkerhedsretningslinjer og driftsprincipper for modeller som testo 405i, 410i, 510i, 549i, 605i, 115i, 905i og 805i. Indeholder produktoversigt.view, tekniske data og godkendelsesoplysninger.
Preview Testo Smart Probes brugermanual og tekniske data
Omfattende guide til Testo Smart Probes, med detaljerede beskrivelser af opsætning, app-brug, måleapplikationer, fejlfinding og tekniske specifikationer for modeller som testo 115i, 405i, 510i og flere.
Preview Testo 521 Differenstrykmanometer - Højpræcisionsmålinger
Udforsk Testo 521-serien af ​​differenstrykmanometre, der tilbyder højpræcisionsmålinger til forskellige anvendelser, herunder HVAC, renrum og ventilationssystemer. Lær om modellerne 521-1, 521-2 og 521-3, deres tekniske specifikationer og tilgængeligt tilbehør.
Preview Testo 176 Datenlogger Bedienungsanleitung
Umfassende Bedienungsanleitung für die Datenlogger der Testo 176 Serie. Enthält technische Daten, Anwendungsbeispiele, Sicherheitshinweise og Wartungsinformationen.