This manual provides essential instructions for the safe installation, operation, and maintenance of your Everbilt HDEFR50W 1/2 HP Cast Iron Effluent Pump with Tethered Switch. Please read this manual thoroughly before installation and operation to ensure proper function and to prevent injury or damage. Keep this manual for future reference.

The Everbilt HDEFR50W is designed for efficient removal of effluent water, capable of handling 1/2 inch solids. Its robust cast iron construction and PSC motor ensure durability and energy efficiency.

Vigtige sikkerhedsoplysninger

ADVARSEL: Manglende overholdelse af disse sikkerhedsinstruktioner kan resultere i elektrisk stød, brand, alvorlig personskade eller død.

Produkt overview

Everbilt HDEFR50W 1/2 HP Effluent Pump with Tethered Switch

Image: Everbilt HDEFR50W 1/2 HP Effluent Pump. This image displays the black cast iron pump unit with its integrated tethered float switch and power cord. The Everbilt logo is visible on the pump body.

Nøglefunktioner:

Specifikationer

FeatureDetalje
MærkeEverbilt
ModelnummerHDEFR50W
VarenummerHDEFR50W
MaterialeStøbejern
StrømkildeElektrisk med ledning
Varens vægt19.1 pund
PumpekapacitetUp to 3180 GPH at 10 ft.
Håndtering af faste stoffer1/2 tomme
UPC858001008774
Pakkedimensioner16.2 x 10.7 x 10 tommer

Opsætning og installation

Proper installation is crucial for the efficient and safe operation of your pump. Consult a qualified electrician or plumber if you are uncertain about any steps.

Installationstrin:

  1. Placering: Position the pump on a solid, level surface in the lowest part of the basin or pit. Ensure it is not resting directly on dirt or gravel, which could clog the intake.
  2. Afgangsrør: Connect a discharge pipe (typically 1-1/2 inch or 2 inch NPT) to the pump's outlet. Use appropriate fittings and ensure all connections are watertight. A check valve should be installed in the discharge line to prevent backflow.
  3. Elektrisk tilslutning: Connect the pump to a dedicated, properly grounded electrical outlet. Ensure the voltage matches the pump's requirements (typically 120V AC). Do not use extension cords.
  4. Justering af flydekontakt: The tethered float switch controls the pump's automatic operation. Adjust the tether length to set the desired ON and OFF levels. Ensure the float can move freely without obstruction within the basin. The float should not touch the sides of the pit or other pipes.
  5. Test: Efter installationen skal b'et udfyldesasin with water to test the pump's operation. Observe that the pump turns on when the water level rises to the ON point and turns off when the water level drops to the OFF point.

Betjeningsvejledning

The Everbilt HDEFR50W pump is designed for automatic operation via its tethered float switch. It can also be operated manually.

Automatisk drift:

When the pump is plugged into a properly grounded outlet and the float switch is set for automatic mode (piggyback plug connected), the pump will activate when the water level rises, lifting the float switch. It will continue to pump until the water level drops, causing the float switch to fall and deactivate the pump.

Manuel betjening:

To operate the pump manually, disconnect the piggyback plug from the wall outlet, then plug the pump's main power cord directly into the wall outlet. The pump will run continuously. Always monitor the pump during manual operation to prevent dry running, which can damage the motor. To stop manual operation, unplug the pump.

Opretholdelse

Regular maintenance ensures optimal performance and extends the life of your pump. Always disconnect power before performing any maintenance.

Fejlfinding

Før du forsøger at reparere pumpen, skal du sørge for, at den er afbrudt fra strømkilden.

ProblemMulig årsagLøsning
Pumpen kører ikke.No power; tripped circuit breaker; float switch stuck; motor overheated.Check power supply and circuit breaker. Ensure float switch moves freely. Allow motor to cool if thermal overload activated.
Pumpen kører kontinuerligt.Float switch stuck in ON position; check valve faulty; discharge pipe leak.Check float switch for obstructions. Inspect check valve and discharge piping.
Low or no water discharge.Clogged intake screen or impeller; air lock; discharge pipe obstruction.Clean intake screen and impeller. Clear any air lock by tilting the pump. Check discharge pipe for blockages.
Pumpen cykler for ofte.Float switch set too low; backflow from discharge pipe.Adjust float switch to allow for a larger ON/OFF cycle. Ensure check valve is functioning correctly.

Garanti og support

For warranty information or technical support, please refer to the documentation included with your purchase or contact Everbilt customer service directly. Keep your purchase receipt as proof of purchase.

For yderligere hjælp, besøg Everbilt official webwebsted or contact their support line.

Relaterede dokumenter - HDEFR50W

Preview EVERBILT Effluent Pump Quick Reference Guide
Quick reference guide for installing and testing the EVERBILT Effluent Pump, detailing basin preparation, discharge piping, power connection, and operation testing procedures.
Preview Brugs- og vedligeholdelsesvejledning til Everbilt dykpumpe til spildevand
This guide provides essential information for the Everbilt Submersible Effluent Pump (Model HDEFR50W), covering safety precautions, installation requirements, operation procedures, maintenance tips, and troubleshooting solutions. Learn how to properly install, operate, and care for your pump to ensure efficient and safe performance.
Preview Brugs- og vedligeholdelsesvejledning til Everbilt dykpumpe | SBA025BC, SBA033BC, SBA033V1, SBA050BC
Omfattende brugs- og vedligeholdelsesvejledning til Everbilt dykpumper, herunder installation, betjening, sikkerhedsoplysninger, vedligeholdelse og fejlfinding for modellerne SBA025BC, SBA033BC, SBA033V1 og SBA050BC. Find kontaktoplysninger og specifikationer.
Preview Brugs- og vedligeholdelsesvejledning til Everbilt dykpumpe
Denne vejledning indeholder vigtige oplysninger om sikker og effektiv brug og vedligeholdelse af Everbilt dykpumper. Den dækker ydelsesspecifikationer, sikkerhedsforanstaltninger, installationstrin, betjening, vedligeholdelse og fejlfinding for modeller, herunder SP03302VD, SP05002VD, PSSP07501VD og PSSP10001VD.
Preview Installationsvejledning til Everbilt vandtætningstilbehør
Omfattende installationsvejledning til Everbilt vandtætningstilbehør, med detaljer om forberedelse af undergulv, samlinger, hjørne- og rørforsegling og endelig flisepåføring til vandtætte installationer.
Preview Brugs- og vedligeholdelsesvejledning til Everbilt dykpumpe (PSSP10001EP, PSSP07501VD)
Denne vejledning indeholder vigtige oplysninger om sikker og effektiv brug, pleje og vedligeholdelse af Everbilt dykpumper, modellerne PSSP10001EP og PSSP07501VD. Den indeholder specifikationer, monteringsvejledning, betjeningsdetaljer og tips til fejlfinding.