Gewiss GWD6781

GEWISS GWD6781 Digital Weekly Timer Switch Instruction Manual

Model: GWD6781 | Brand: Gewiss

1. Introduktion

This manual provides comprehensive instructions for the installation, setup, and operation of your GEWISS GWD6781 Digital Weekly Timer Switch. This device is designed for weekly programming of electrical circuits, ideal for applications such as ventilation, lighting, heating, and irrigation systems. Please read this manual carefully before use to ensure correct and safe operation.

GEWISS GWD6781 Digital Weekly Timer Switch

Figure 1: GEWISS GWD6781 Digital Weekly Timer Switch. This image shows the front view of the timer switch, featuring its digital display, control buttons, and terminal connections.

2. Sikkerhedsoplysninger

ADVARSEL: Electrical installation and maintenance should only be performed by qualified personnel. Failure to follow these instructions can result in electric shock, fire, or serious injury.

3. Produktet er slutview

The GEWISS GWD6781 is a compact digital timer switch designed for DIN rail mounting. It features a clear digital display and intuitive controls for setting weekly programs.

Nøglekomponenter:

The device includes a 4-year power reserve, ensuring that the internal clock and programmed settings are maintained during power outages.

4. Installation

4.1 Montering

  1. Ensure all power to the electrical panel is disconnected.
  2. Locate an available slot on a standard 35mm DIN rail. The GWD6781 occupies 1 module (18mm) width.
  3. Hook the top edge of the timer onto the DIN rail, then push the bottom edge firmly until it clicks into place.

4.2 Ledningsføring

The GWD6781 features a single normally open (NA) contact, rated for 16 A at 230 VAC.

Refer to the wiring diagram printed on the side of the device for precise connections. Ensure all connections are secure.

5. Opsætning

5.1 Indledende opstart

Once correctly wired and mounted, restore power to the circuit. The display should illuminate. If it's the first time powering up or after a prolonged power outage, the display might show a default time or require initial setup.

5.2 Indstilling af aktuel tid og dag

  1. Tryk og hold på PRG button until the time or day setting starts flashing.
  2. Brug Up og Ned arrow buttons to adjust the hour, then press PRG for at bekræfte og gå til minutter.
  3. Adjust minutes, then press PRG to confirm and move to day of the week.
  4. Adjust the day (e.g., 1 for Monday, 2 for Tuesday, etc.), then press PRG to save and exit the time/day setting mode.

The internal battery reserve ensures that the time and programmed settings are retained for up to 4 years even without external power.

6. Betjeningsvejledning

The GWD6781 allows for weekly programming using up to 48 "virtual trestles" or program segments. Each segment represents a 30-minute interval, allowing for precise control over your electrical devices.

6.1 Programmering af tænd/sluk-cyklusser

  1. Tryk på PRG button briefly to enter programming mode. The display will show a program number (e.g., P01) and a flashing ON/OFF indicator.
  2. Brug Up og Ned arrows to select the desired program number (P01 to P48).
  3. Trykke PRG to set the ON time for the selected program. Use the arrows to adjust the hour and minutes, then press PRG for at bekræfte.
  4. Next, set the OFF time for the same program using the arrows and PRG knap.
  5. After setting both ON and OFF times, you can select the days of the week for this program to be active. Use the arrows to cycle through day options (e.g., all days, weekdays, weekends, individual days). Press PRG for at bekræfte valget af dag.
  6. To add more programs, repeat steps 2-5. To exit programming mode, press and hold the PRG knap.

6.2 Manuel tilsidesættelse

The GWD6781 may feature a manual override function to temporarily switch the output ON or OFF, independent of the programmed schedule. Consult the device's display or a quick press of an arrow button (if applicable) to activate this feature. The display will typically indicate 'ON' or 'OFF' manually.

7. Vedligeholdelse

7.1 Udskiftning af batteri

The GWD6781 contains an internal battery for power reserve. If the display becomes dim or settings are lost frequently during power outages, the battery may need replacement.

7.2 Rengøring

Rengør enhedens yderside med en blød, tør klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.

8. Fejlfinding

If problems persist, contact a qualified electrician or GEWISS customer support.

9. Specifikationer

MærkeGewiss
ModelnummerGWD6781
Voltage230 Vca
Nuværende vurdering16 A
Kontakttype1 Normally Open (NA)
MonteringDIN Rail (1 module / 18 mm)
Programmeringsintervaller30 minutter minimum
Antal programmerUp to 48 (virtual trestles)
Power Reserve4 år
Vægt53.3 g

10. Garanti og support

GEWISS products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your product or visit the official GEWISS website. For technical support or service, please contact your local GEWISS distributor or customer service center.

Du kan finde yderligere oplysninger og kontaktoplysninger på den officielle GEWISS webwebsted.

Relaterede dokumenter - GWD6781

Preview GEWISS CHORUSMART CVD 4X10A DIN-skinne LED-dæmper - Tekniske specifikationer
Detaljerede tekniske specifikationer og installationsvejledning til GEWISS CHORUSMART CVD 4X10A DIN-skinneforstærkeren, der er designet til at udvide LED-dæmperens styrekapacitet.
Preview GEWISS CHORUSMART Booster for CVD LED Dimmer 4x16A - DIN Rail Mounting
Technical specifications and installation guide for the GEWISS CHORUSMART Booster, model GW90768, designed to extend CVD LED dimmer control capacity up to 16A per channel. Suitable for DIN rail mounting and KNX systems.
Preview Installations- og teknisk vejledning til Gewiss CHORUSMART Connected Axial Dimmer Module
Omfattende guide til Gewiss CHORUSMART Connected Axial Dimmer Module (GWA1221, GWA1222), der dækker installation, funktioner, tekniske specifikationer, Zigbee-forbindelse og sikkerhedsoplysninger.
Preview GEWISS CHORUSMART CVD LED Dimmer Booster 4x10A Installation Guide
Installation and technical specifications for the GEWISS CHORUSMART CVD LED Dimmer Booster, model GW 90766. This device amplifies control capacity for LED dimmers, supporting up to 10A per channel and DIN rail mounting.
Preview GEWISS Chorusmart GW10677/GW10678 Axial Command Module: Installation og teknisk vejledning
Omfattende vejledning til GEWISS Chorusmart GW10677 og GW10678 hjælpeaksiale kommandomoduler. Dækker sikkerhed, generel information, LED-funktioner, tilslutningseksemplerampinformation, montering, vedligeholdelse og tekniske specifikationer for smart home automation.
Preview GEWISS GWD6821 LAN Gateway: Tekniske specifikationer og installationsvejledning
Detaljerede tekniske specifikationer, installationsvejledning og Modbus-registerkortlægningview til GEWISS GWD6821 LAN Gateway, der muliggør kommunikation for energimålere.