1. Produktet er slutview
The EPEVER Tracer1206AN-GC is a 10A Maximum Power Point Tracking (MPPT) solar charge controller designed for 12V/24V automatic system voltage detection. It efficiently manages power from solar panels, supporting a maximum PV input of 60V. This controller is suitable for various battery types, including Lead-acid (Sealed, Gel, Flooded) and Lithium (LiFePO4, Li(NiCoMn)O2), featuring common negative grounding for enhanced safety.

Figure 1: EPEVER Tracer1206AN-GC MPPT Solar Charge Controller
2. Nøglefunktioner
- Avanceret MPPT-teknologi: Achieves tracking efficiency of no less than 99.5% and a maximum conversion efficiency of 98%. Features ultra-fast tracking speed and accurate recognition of multiple-peaks maximum power point.
- Automatisk systemvolumentage: Automatically detects 12V/24V DC system voltages.
- Bred batterikompatibilitet: Supports Lead-acid (Sealed, Gel, Flooded) and Lithium (LiFePO4, Li(NiCoMn)O2) batteries, including a Lithium battery automatic activation function.
- Omfattende beskyttelse: Includes overcharging, over-discharging, overload, short-circuit, reverse polarity, and over-temperature protection.
- LCD-skærm: Blacklight LCD display provides clear system operating information and data.
- Remote Monitoring & Control: RS-485 communication bus interface with Modbus protocol allows monitoring and parameter setting via mobile phone APP or PC software.
- Temperaturkompensation: Battery temperature compensation function (for Lead-acid batteries only) ensures optimal charging.
- Energistatistik: Real-time energy statistics function for system performance tracking.
- Common Negative Grounding: Enhances system safety.
3. Specifikationer
| Parameter | Værdi |
|---|---|
| Model | Tracer1206AN-GC |
| Nominel lade-/afladningsstrøm | 10 Amp |
| Nominelt System Voltage | 12V/24V DC Auto Work |
| Maks. PV-indgangseffekt | 130W (12V system) / 260W (24V system) |
| Maks. PV Open Circuit Voltage | 60V (at min. operating temp) / 46V (at 25℃ temp) |
| Batteritype | Lead-acid (Sealed/Gel/Flooded), Lithium (LiFePO4/Li(NiCoMn)O2), User-defined |
| Batteri VoltagRækkevidde | 8-32V |
| MPP bindtagRækkevidde | V(BAT+2V)-36V |
| Jordforbindelse | Almindelig negativ |
| Sporingseffektivitet | ≥99.5 % |
| Maks. Konverteringseffektivitet | 98 % |
| Driftstemperatur | -25℃ to +50℃ (100% input and output) |
| Dimensioner (L×B×H) | 172×139×44 mm |
| Varens vægt | 0.6 kg |
| Display Type | LCD |
| Kommunikationsgrænseflade | RS485 (RJ45) |

Figure 2: EPEVER Tracer1206AN-GC Dimensions (172x139x44mm)
4. Opsætning og installation
Proper installation is crucial for the safe and efficient operation of your solar system. Follow these steps carefully:
- Montering: Mount the controller in a well-ventilated area, away from direct sunlight and heat sources. Ensure adequate clearance around the unit for heat dissipation.
- Ledningsrækkefølge: Connect the components in the following order to prevent damage:
- 1. Batteri: Connect the battery to the charge controller's battery terminals (+ and -). Ensure correct polarity.
- 2. Indlæs: Connect the DC load to the controller's load terminals (+ and -).
- 3. Solar Panel: Connect the solar panel to the controller's PV terminals (+ and -). Ensure correct polarity.
- Afbrydelsessekvens: To disconnect the system, reverse the connection order: 1. Solar Panel, 2. Load, 3. Battery.
- Ledningsstørrelse: Use appropriate wire gauges for all connections to minimize voltage drop and ensure safety. Recommended wire cable for the controller terminals is #12 AWG (4mm²).

Figure 3: Wiring Diagram for EPEVER MPPT Solar Charge Controller. Connect battery first, then load, then PV panel. Disconnect in reverse order.
Video 1: This video demonstrates the installation process for a solar charge controller, highlighting the correct wiring sequence for safe and effective setup.
5. Betjeningsvejledning
The Tracer1206AN-GC features an LCD display and buttons for easy operation and monitoring.
5.1 LCD-skærm
The LCD provides real-time data on battery voltage, charging current, PV voltage, and system status. Use the 'SELECT' and 'ENTER' buttons to navigate through different display screens and adjust settings.

Figure 4: The LCD display shows real-time system information and allows for easy navigation through settings.
5.2 Indstilling af batteritype
The controller supports various battery types. It is essential to select the correct battery type for optimal charging and battery longevity. Refer to the manual for detailed instructions on how to set the battery type via the LCD or monitoring software.
5.3 Belastningskontrol
The controller offers multiple load work modes. These modes can be configured to control when the DC load is active, optimizing energy usage. Consult the manual for specific load control settings.
6. Batterikompatibilitet
The Tracer1206AN-GC is designed to be compatible with a wide range of battery technologies:
- Lead-acid Batteries:
- Forseglet
- Gel (AGM)
- Oversvømmet
- Lithium-batterier:
- LiFePO4 (4s/12V; 8s/24V)
- Li (NiCoMn)O2 (3s/12V; 6s/24V)
- Brugerdefineret: Customizable settings for other battery types.

Figure 5: The controller supports various battery types including deep cycle sealed, gel, flooded, and lithium.
7. Beskyttelsesfunktioner
The Tracer1206AN-GC incorporates multiple electronic protections to safeguard your solar system and connected devices:
- Over Charging Protection: Prevents batteries from being overcharged, extending their lifespan.
- Over Discharging Protection: Disconnects the load when battery voltage drops below a safe level, preventing deep discharge.
- Overbelastningsbeskyttelse: Automatically disconnects the load if the current exceeds the rated capacity.
- Kortslutningsbeskyttelse: Protects against short circuits in the load or PV array.
- Omvendt polaritetsbeskyttelse: Safeguards the controller and battery from damage due to incorrect wiring of battery or PV terminals.
- Over temperatur beskyttelse: Reduces charging power or shuts down if the controller's internal temperature becomes too high.
- Charging Power and Current Limitation: Prevents excessive power or current from damaging the battery or controller.

Figure 6: The controller features multiple electronic protections to prevent damage from installation errors or system failures.
8. Monitoring & Connectivity
The Tracer1206AN-GC offers advanced monitoring and communication capabilities:
- RS-485 kommunikation: Equipped with an RS-485 communication bus interface and Modbus communication protocol. This allows for robust and reliable data exchange.
- Mobile App & PC Software: Monitor and set parameters remotely via a dedicated mobile phone application or PC software. This provides detailed insights into system performance and allows for customized settings.

Figure 7: Monitor and set parameters remotely via mobile phone app or PC software.
Video 2: Denne video giver en oversigtview of the EPEVER G3 Version TracerAN MPPT Solar Charge Controller, showcasindens funktioner og tilslutningsmuligheder.
9. Vedligeholdelse
Regular maintenance ensures the longevity and optimal performance of your EPEVER Tracer1206AN-GC MPPT Solar Charge Controller. Perform the following checks periodically:
- Visuel inspektion: Check for any loose connections, damaged wiring, or signs of corrosion on the terminals.
- Renhed: Ensure the controller's casing and ventilation openings are free from dust and debris to prevent overheating.
- Firmwareopdateringer: Periodically check for and apply any available firmware updates via the mobile app or PC software to ensure the controller has the latest features and bug fixes.
- Batteriets sundhed: Overvåg batteri voltage and charging status regularly to ensure proper battery health. For Lead-acid batteries, check electrolyte levels if applicable.
- Temperatursensor: Ensure the remote temperature sensor (if used) is securely connected and positioned correctly for accurate readings.

Figure 8: The remote temperature sensor measures battery temperature and provides compensation for optimal charging.
10. Fejlfinding
If you encounter issues with your Tracer1206AN-GC, refer to the following common troubleshooting steps:
- Ingen skærm/strøm: Kontroller batteriforbindelserne og sørg for, at batteriets volumtage is within the operating range (8-32V). Verify all wiring is secure and correctly polarized.
- Ingen opladning: Ensure solar panels are receiving adequate sunlight and are connected correctly to the PV terminals. Check PV open circuit voltage and current. Verify that the battery type setting matches your battery.
- Indlæsning virker ikke: Check load connections and ensure the load current does not exceed the controller's rated output. Verify the load work mode settings. Check for any active protection warnings on the LCD.
- Fejlkoder: If the LCD displays an error code, consult the full user manual for specific code meanings and recommended actions.
- Kommunikationsproblemer: Ensure the RS-485 cable is properly connected. If using a mobile app or PC software, verify the communication adapter (e.g., Bluetooth, WiFi) is correctly installed and configured.
11. Garanti og support
EPEVER products are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official EPEVER webwebsted.
For technical assistance, troubleshooting, or any questions regarding your EPEVER Tracer1206AN-GC MPPT Solar Charge Controller, please contact Goland Century, an EPEVER Official Authorized Supplier. Their professional engineers can provide solar system solutions and services.
Kontaktoplysninger: Refer to your purchase documentation or the official EPEVER/Goland Century website for the latest support contact details.