Indledning
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your OLMO 9,000 BTU 230V Ductless Mini Split Air Conditioner & Heat Pump. This system is designed to provide high-performance heating and cooling, suitable for various spaces including bedrooms, offices, and compact living areas. Please read this manual thoroughly before installation and use, and retain it for future reference.
Sikkerhedsoplysninger
Vigtige sikkerhedsinstruktioner:
- Sørg altid for, at enheden er korrekt jordforbundet.
- Do not attempt to install or service the unit yourself. Professionel installation er påkrævet.
- Turn off all power to the unit before performing any maintenance or cleaning.
- Hold området omkring udendørsenheden fri for forhindringer for at sikre korrekt luftgennemstrømning.
- Stik ikke fingre eller genstande ind i luftindtaget/-udtaget.
- Hvis forsyningsledningen er beskadiget, skal den udskiftes af producenten, dennes serviceagent eller lignende kvalificerede personer for at undgå en fare.
- Dette apparat er ikke beregnet til brug af personer (inklusive børn) med nedsatte fysiske, sensoriske eller mentale evner, eller mangel på erfaring og viden, medmindre de har fået opsyn eller instruktion i brugen af apparatet af en person, der er ansvarlig for deres sikkerhed.
Forslag 65 Advarsel: Dette produkt kan udsætte dig for kemikalier, herunder bly, som er kendt af staten Californien for at forårsage kræft og fødselsdefekter eller anden reproduktionsskade. For mere information gå til www.P65Warnings.ca.gov.
Pakkens indhold
Kontroller, at alle komponenter er til stede og ubeskadigede ved udpakning:
- Indoor Wall Mount Air Handler Unit
- Udendørs kondensatorenhed
- 16FT Insulated Copper Line Set
- 16FT Communication Cable
- 16FT Drainage Extension
- Fjernbetjening
- Small accessories for installation

Figure 1: Included components of the OLMO Mini Split System.
Opsætning og installation
Note: This is not a DIY system. Professional installation by a qualified HVAC technician is required to ensure proper function, safety, and warranty validity. The condenser comes pre-charged with refrigerant.
Kontrol før installation:
- Ensure the installation location for both indoor and outdoor units meets clearance requirements for proper airflow and maintenance access.
- Verify that the electrical supply matches the unit's requirements (230V for this model). A dedicated power source is recommended.
- Confirm the integrity of the pre-charged line set and all included accessories.
Installation overståetview (for Professional Reference):
- Mount the indoor unit securely on the wall, ensuring proper drainage slope.
- Position the outdoor condenser unit on a stable, level surface, away from obstructions.
- Connect the insulated copper line set between the indoor and outdoor units. Ensure proper flaring and torque.
- Connect the communication cable and drainage extension.
- Evacuate the system using a vacuum pump to remove air and moisture from the refrigerant lines.
- Open the valves on the outdoor unit to release the pre-charged refrigerant into the system.
- Connect the unit to the dedicated electrical circuit.
- Perform a leak check and test run to ensure proper operation.

Figure 2: The complete OLMO Mini Split System.

Figure 3: Indoor Unit of the OLMO Mini Split System.

Figure 4: Outdoor Condenser Unit of the OLMO Mini Split System.
Betjeningsvejledning
Your OLMO Mini Split system offers various modes and features for optimal comfort. All functions are controlled via the included remote control.

Figure 5: Remote Control for the OLMO Mini Split System.
Grundlæggende betjening:
- Tænd/sluk: Tryk på ON/OFF knappen for at starte eller stoppe enheden.
- Valg af tilstand: Tryk på MODE knap til at gennemgå tilgængelige tilstande:
- Afkøle: Til afkøling af rummet.
- Varme: Til opvarmning af rummet (varmepumpefunktion).
- Dry (Dehumidify): To reduce humidity.
- Ventilator: Cirkulerer luft uden opvarmning eller afkøling.
- Auto: Vælger automatisk tilstand baseret på rumtemperatur.
- Temperaturjustering: Brug TEMP ▲/▼ for at indstille den ønskede temperatur.
- Blæserhastighed: Tryk på FAN button to adjust fan speed (Auto, Low, Medium, High).
- Louver Auto Swing: Activates automatic vertical louver movement for even air distribution.
Avancerede funktioner:
- Comfortable Sleep Mode: Adjusts temperature automatically during sleep for energy efficiency and comfort.
- Timer funktion: Indstil enheden til at tænde eller slukke automatisk på et bestemt tidspunkt.
- Selvdiagnose: The unit can perform self-diagnosis and display error codes on the LED display.
- Intelligent Pre-heating: In heating mode, the unit pre-heats before blowing air to prevent cold drafts.
- Automatisk genstartsfunktion: Enheden genstarter automatisk med de tidligere indstillinger efter et strømafbrydelse.tage.
- LED display: Provides real-time temperature and status information.

Figure 6: The OLMO Mini Split System providing comfort in a living space.
Opretholdelse
Regular maintenance ensures optimal performance and longevity of your OLMO Mini Split system. Always disconnect power before performing maintenance.
Rengøring af luftfilter:
- The indoor unit features washable filters.
- Åbn frontpanelet på indendørsenheden.
- Fjern luftfiltrene.
- Rengør filtrene med en støvsuger, eller vask dem med lunkent vand og et mildt rengøringsmiddel.
- Lad filtrene tørre helt, før de sættes i igen.
- Rengør filtrene hver anden uge eller oftere afhængigt af brug og luftkvalitet.
Vedligeholdelse af udendørsenhed:
- Hold området omkring udendørsenheden fri for snavs, blade og sne.
- Periodically clean the outdoor coil with a soft brush or vacuum cleaner to remove dirt and dust.
- Ensure the drainage outlet is not blocked.
- For detailed cleaning and professional checks, it is recommended to schedule annual maintenance with a qualified technician.
Fejlfinding
Before contacting technical support, please refer to the following common issues and solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke. | Ingen strømforsyning; Fjernbetjeningens batterier er døde. | Check circuit breaker; Replace remote control batteries. |
| Utilstrækkelig køling/opvarmning. | Dirty air filters; Obstruction to airflow; Incorrect mode setting; Low refrigerant. | Clean air filters; Remove obstructions; Select correct mode; Contact professional for refrigerant check. |
| Usædvanlig støj. | Løse dele; Ventilatorblokering; Enhed ikke i vater. | Check for loose parts; Clear fan area; Ensure unit is level. If noise persists, contact support. |
| Vandlækage fra indendørsenheden. | Tilstoppet afløbsrør; Forkert installation. | Clear drain pipe; Contact professional for inspection. |
Specifikationer
Detailed technical specifications for the OLMO 9,000 BTU 230V Mini Split System:
| Feature | Detalje |
|---|---|
| Mærkenavn | ELM |
| Model info | Alpic |
| Varemodelnummer | OS-EL09ALP230V |
| Produktdimensioner | 48 x 40 x 40 inches (Shipping) |
| Kølekapacitet | 9,000 BTU |
| Varmekapacitet | Heat Pump Functionality |
| Voltage | 230 volt |
| Sæsonbestemt energieffektivitetsforhold (SEER) | 16.5 |
| Sæsonbestemt varmeydelsesfaktor (HSPF) | 9.4 |
| Installationstype | Opdelt system |
| Kølemiddel | R410A |
| Særlige funktioner | LED Display, Defrost, Heating, Inverter Technology, Louver Auto Swing, Remote Included, Comfortable Sleep Mode, Multiple Fan Speeds, Timer, Self Diagnosis, Intelligent Pre-heating, Auto Restart Function |
| Farve | Hvid |
| Strømkilde | Elektrisk med ledning |

Figure 7: EnergyGuide Label for OLMO Mini Split System.

Figure 8: Comprehensive Technical Specifications Table for OLMO Mini Split Systems.
Garanti og support
OLMO provides US-based technical support for your product. If you encounter any issues or require assistance with your mini split system, please contact our support team. Professional installation is required for warranty validity.
For support, please refer to the contact information provided with your purchase documentation or visit the official OLMO webwebsted.