MERCURY MR50-S3

MERCURY SECURITY MR50-S3 Enkelt Kortlæser Interface Controller Board Brugermanual

1. Introduktion

The MERCURY SECURITY MR50-S3 is a high-performance single-card reader interface panel designed for access control systems. It facilitates communication between a card reader and an intelligent controller, offering a compact and economical solution for managing a single door. This board supports various reader technologies and provides essential input/output capabilities for secure door control.

2. Produktet er slutview

The MR50-S3 board integrates multiple components for robust operation. Understanding the layout and function of these components is crucial for proper installation and maintenance.

Top-down view of the MERCURY SECURITY MR50-S3 Single Card Reader Interface Controller Board, showing its red PCB, various electronic components, terminal blocks, and an 'AUTHENTIC MERCURY' logo.

Figure 1: MERCURY SECURITY MR50-S3 Controller Board

This image displays the MERCURY SECURITY MR50-S3 controller board. Key components visible include multiple terminal blocks (TB1, TB2, TB3, TB4) for connections such as power (VIN, GND), reader data (CLK/D1, DAT/D0, TR+, TR-), inputs (NC, NO), and relays (K1, K2). The board features several integrated circuits (ICs), resistors, capacitors, and two relays (K1, K2). A prominent 'AUTHENTIC MERCURY' logo is centered on a large IC. The board is marked with '10224-0081-F REV-E MSP (C)2016' and 'TH-15 94V-0A 1006. E164576', indicating its model, revision, and manufacturing details. A yellow 8-pin header (S1) is also visible on the right side.

3. Opsætning

3.1. Installationskrav

  • Compatible intelligent controller (e.g., HID Mercury intelligent controllers).
  • Appropriate power supply (refer to specifications for voltage og nuværende).
  • Single card reader (OSDP, Wiegand, Clock/Data, Magnetic Stripe, F2F, Supervised F2F, Keypad, or Biometric).
  • Necessary wiring for power, communication, reader, inputs, and relays.

3.2. Ledningsinstruktioner

Ensure all power is disconnected before performing any wiring. Connect the MR50-S3 board to the intelligent controller via RS-485. Connect the card reader to the designated reader port, ensuring correct data and power connections. Wire the door's lock mechanism to the appropriate relay output (K1 or K2) and connect door sensors or other inputs to the general purpose inputs. Refer to the detailed wiring diagrams provided with your complete access control system documentation for specific connections.

4. Betjeningsvejledning

Once installed and configured with a compatible intelligent controller, the MR50-S3 operates by receiving data from the connected card reader. This data is then transmitted via RS-485 to the intelligent controller for authentication. Upon successful authentication, the controller sends a command back to the MR50-S3 to activate the designated relay, thereby unlocking the door.

  • Reader Port: Supports one reader, or up to two OSDP readers.
  • Card/Keypad Data: Compatible with OSDP, Clock/Data, Data-1/Data-0, RS-485, or F/2F formats.
  • Dørkontrol: Manages the access for a single door.

5. Vedligeholdelse

The MR50-S3 board is designed for reliable operation with minimal maintenance. Periodically inspect the board and its connections for any signs of damage, loose wiring, or dust accumulation. Ensure the operating environment remains within specified temperature and humidity ranges to prevent component degradation. Cleaning should be performed with a soft, dry brush or compressed air; avoid using liquids or abrasive materials.

6. Fejlfinding

If the MR50-S3 board is not functioning as expected, consider the following basic troubleshooting steps:

  • Ingen strøm: Verify the power supply connections and ensure the correct voltage is being supplied to the board. Check for any blown fuses if applicable.
  • Læseren svarer ikke: Confirm the reader is correctly wired to the MR50-S3 and that the reader itself is powered. Check for proper data format configuration.
  • Kommunikationsproblemer: Ensure the RS-485 connection to the intelligent controller is secure and correctly terminated. Verify communication settings in the access control software.
  • Døren låser ikke op: Check the wiring to the door lock and the relay output. Confirm that the intelligent controller is sending the unlock command.

For persistent issues, consult the complete system documentation or contact technical support.

7. Specifikationer

  • Model: MR50-S3
  • Reader Ports: 1 (supports up to 2 OSDP readers)
  • Card/Keypad Data: OSDP, Clock/Data, Data-1/Data-0, RS-485, F/2F
  • Dørkontrol: 1 dør
  • Indgange: 3 (2 General Purpose, 1 Dedicated Tamper)
  • Relæer: 2 (1 x NO 5A @ 30VDC or NC 3A @ 30VDC, 1 x 2A @ 30VDC)
  • Forbindelse: RS-485
  • Varens vægt: 7.2 ounce
  • Speciel funktion: Compact design for versatility
  • Kompatible enheder: Biometric Device, Camera, Personal Computer

8. Garantioplysninger

For detailed warranty terms and conditions, please refer to the official MERCURY SECURITY website or the documentation provided with your purchase. Warranty coverage typically includes defects in materials and workmanship under normal use for a specified period.

9. Support

If you require technical assistance, have questions regarding installation, or need further support, please contact MERCURY SECURITY customer service or your authorized distributor. Ensure you have your product model number (MR50-S3) and any relevant system details available when seeking support.

Relaterede dokumenter - MR50-S3

Preview Vilkår og betingelser for Mercury Rewards
Officielle vilkår og betingelser for Mercury Rewards, der beskriver, hvordan man optjener, indløser og administrerer point, berettigelse og programvariationer. Gældende fra 17. marts 2025.
Preview Руководство пользователя подвесного двигателя Mercury 25/30 EFI 4-тактный
Полное руководство пользователя для подвесных двигателей Mercury 25/30 EFI 4-taktisk, hastighedsovervågende, støber, техническое обслуживание, гарантию og устранение неисправностей.
Preview Mercury MTM01 digitalt multimeter: Brugermanual og specifikationer
Udforsk Mercury MTM01 digitalt multimeter med denne omfattende brugermanual. Opdag detaljerede betjeningsvejledninger, tekniske specifikationer, sikkerhedsforanstaltninger og målevejledninger til nøjagtig elektrisk testning.
Preview Mercury NZ Limiteds årlige generalforsamling 2025: Stemme- og fuldmagtsvejledning
Official voting and proxy form for the Mercury NZ Limited 2025 Annual Shareholders' Meeting. Learn how to cast your vote or appoint a proxy for the meeting on September 19, 2025.
Preview Mercury Phone & Internet Vilkår og betingelser for privatkunder
Officielle vilkår og betingelser for Mercurys telefon- og internettjenester til private, gældende fra 21. oktober 2025. Dækker tjenestetilgængelighed, kundens ansvar, oplysninger om internettjenesten, software/hardware, indhold, nødopkald, fejl og opsigelse.
Preview Asus RT-N10E Fibre Setup Guide for Mercury Broadband
Step-by-step instructions to set up your Asus RT-N10E router for Mercury fibre broadband, including gateway login and WAN settings.